Improvement of the signal-to-noise ratio in interferometry using multi-frame high-dynamic-range and normalization algorithms

被引:7
|
作者
Restrepo, Rene [1 ]
Uribe-Patarroyo, Nestor [1 ]
Belenguer, Tomas [1 ]
机构
[1] Inst Nacl Tecn Aeroespacial INTA, Lab Nacl Instrumentac Espacial LINES, E-28850 Madrid, Spain
关键词
High dynamic range (HDR); Normalization; Fringe analysis; Liquid crystals (LC); CRYSTAL VARIABLE RETARDERS;
D O I
10.1016/j.optcom.2011.10.077
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Using both high dynamic range (HDR) and normalization methodologies, we show a method to improve the fringe pattern contrast in interferometric measurements normally used for phase recovering. In a simulated interferogram that mimics the main effects that can be found in an interferometric process (stray-light, photon noise, electronic noise, scattering phenomena, etc.) it was possible to improve the contrast of the fringes and to decrease the root mean square error by more than 35%. The method proposed is applied to experimental interferograms to measure wavefront error and retardance changes on liquid crystal (LC) devices. It is done by using a Mach-Zehnder set-up in which we used different polarization areas. The proposed method increases the quality of the phase recovered and decreases the root mean square error by 50%. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:546 / 552
页数:7
相关论文
共 50 条
  • [41] High signal-to-noise ratio ultrasonic testing system using chirp pulse compression
    Iizuka, Y.
    Insight: Non-Destructive Testing and Condition Monitoring, 1998, 40 (04): : 282 - 285
  • [42] High signal-to-noise ratio ultrasonic testing system using chirp pulse compression
    Iizuka, Y
    INSIGHT, 1998, 40 (04) : 282 - 285
  • [43] Signal-to-noise ratio effects in quantitative cerebral perfusion using dynamic susceptibility contrast agents
    Smith, MR
    Lu, H
    Frayne, R
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 122 - 128
  • [44] Double-sampling to improve signal-to-noise ratio (SNR) of dynamic spectrum (DS) in full spectral range
    Li, Gang
    Zhou, Mei
    Lin, Ling
    OPTICAL AND QUANTUM ELECTRONICS, 2014, 46 (05) : 691 - 698
  • [45] Improvement of the signal to noise ratio of CMOS image sensor by multi-frame-smooth FPN with microscanning
    Shou, Shan-Xiong
    Chen, Jin-Yong
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2002, 36 (06): : 621 - 623
  • [46] Double-sampling to improve signal-to-noise ratio (SNR) of dynamic spectrum (DS) in full spectral range
    Gang Li
    Mei Zhou
    Ling Lin
    Optical and Quantum Electronics, 2014, 46 : 691 - 698
  • [47] Relationship between the charge-coupled device signal-to-noise ratio and dynamic range with respect to the analog gain
    Wang, Dejiang
    Zhang, Tao
    Kuang, Haipeng
    APPLIED OPTICS, 2012, 51 (29) : 7103 - 7114
  • [48] Contrast, resolution, pixelation, dynamic range and signal-to-noise ratio: fundamental limits to resolution in fluorescence light microscopy
    Stelzer, EHK
    JOURNAL OF MICROSCOPY-OXFORD, 1998, 189 : 15 - 24
  • [49] Robust Multi-Frame Joint Frequency Hopping Radar Waveform Parameters Estimation Under Low Signal-Noise-Ratio
    Wei, Song
    Zhang, Man
    Wang, Guanyong
    Sun, Xiping
    Zhang, Lei
    Chen, Daqing
    IEEE ACCESS, 2019, 7 : 177198 - 177210
  • [50] Robust Frame Synchronization for Low Signal-to-Noise Ratio Channels Using Energy-Corrected Differential Correlation
    Lee, Dong-Uk
    Kim, Pansoo
    Sung, Wonjin
    EURASIP JOURNAL ON WIRELESS COMMUNICATIONS AND NETWORKING, 2009,