Breakdown and voltage-time characteristics of turn-to-turn models for an HTS transformer

被引:5
|
作者
Baek, Seung Myeong [1 ]
Kim, Sang Flyun [2 ,3 ]
机构
[1] Chongwon Coll, Dept Fire Prot Engn, Chang Won 641771, South Korea
[2] Gyeongsang Natl Univ, Dept Elect Engn, Jinju 660701, South Korea
[3] Engn Res Inst, Jinju 660701, South Korea
关键词
breakdown; electric field; high-temperature superconducting (HTS) transformer; turn-to-turn models; voltage-time characteristics;
D O I
10.1109/TASC.2008.917537
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The breakdown and voltage-time characteristics of turn-to-turn models for point contact geometry and surface contact geometry using copper multiwrapped with polyimide film for a high-temperature superconducting transformer were investigated under ac and impulse voltage at 77 K. Polyimide film (Kapton) 0.025 mm thick is used for multiwrapping of the electrode. As expected, the breakdown voltages for the surface contact geometry are lower than that of the point contact geometry, because the contact area of the surface contact geometry is lager than that of the point contact geometry. The time to breakdown t(50) decreases as the applied voltage is increased, and the lifetime indexes increase slightly as the number of layers is increased. The electric field amplitude at the position where breakdown occurs is about 80% of the maximum electric field value.
引用
收藏
页码:36 / 41
页数:6
相关论文
共 50 条
  • [41] Breakdown voltage-time characteristics and insulation testing of gas insulated switchgear
    Okabe, Shigemitsu
    Takami, Jun
    Tsuboi, Toshihiro
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (03) : 725 - 736
  • [42] Accelerated aging, partial discharges and breakdown of Type II turn-to-turn insulation system of rotating machines
    Montanari, Gian Carlo
    Cavallini, Andrea
    Ciani, Fabio
    Contin, Alfredo
    2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 190 - 193
  • [43] Turn-to-Turn Fault Diagnosis on Three-Phase Power Transformer Using Hybrid Detection Algorithm
    Liu, Chien-Hsun
    Muda, Willybrordus H. P.
    Kuo, Cheng-Chien
    APPLIED SCIENCES-BASEL, 2021, 11 (06):
  • [44] Breakdown Characteristics of Transformer Turn-insulation Under Double-exponential and Oscillating Switching Impulse Voltage
    Cao D.
    Guo R.
    Cai L.
    Jin Y.
    Hu W.
    Li J.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (06): : 2265 - 2275
  • [45] Magnetic Field Stability Analysis on No-Insulation and Turn-to-Turn Soldered HTS Magnets Under Sinusoidal Noise Operation
    Lee, Woo Seung
    Park, Young Gun
    Kim, Jinsub
    Song, Seunghyun
    Jeon, Haeryong
    Kim, Young-Gyun
    Lee, Haigun
    Ko, Tae Kuk
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (04)
  • [46] Distributed parametric transformer `voltage-time interval'
    Nikitin, Yu.P.
    Pustovoit, A.G.
    Titarenko, Ye.G.
    Engineering Simulation, 1998, 15 (06): : 865 - 867
  • [47] A NEW CALCULATION METHOD OF BREAKDOWN VOLTAGE-TIME CHARACTERISTICS OF LONG AIR GAPS
    SHINDO, T
    SUZUKI, T
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (06): : 1556 - 1563
  • [48] Turn-to-Turn Short Circuit Fault Localization in Transformer Winding via Image Processing and Deep Learning Method
    Moradzadeh, Arash
    Moayyed, Hamed
    Mohammadi-Ivatloo, Behnam
    Gharehpetian, G. B.
    Aguiar, A. Pedro
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2022, 18 (07) : 4417 - 4426
  • [49] Feasibility Study on the Detection of Turn-to-Turn Fault Severity in the Transformer Winding by Frequency Response Analysis and Numerical Indices
    Samimi, Mohammad Hamed
    Faiz, Jawad
    Parchini, Jafar Ghasemi
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023, 51 (09) : 856 - 870
  • [50] Calculation and analysis of three-dimensional model for turn-to-turn short circuit of high voltage reactor
    Wu S.
    Ma H.
    Wei X.
    Chen X.
    Xu H.
    Liu B.
    Song K.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (04): : 148 - 154