Feasibility study of semi-automated measurements of finger joint space widths

被引:6
|
作者
Pfeil, Alexander [1 ]
Sommerfeld, Julia [2 ]
Froeber, Rosemarie [3 ]
Lehmann, Gabriele [1 ]
Malich, Ansgar [4 ]
Hansch, Andreas [2 ]
Wolf, Gunter [1 ]
Boettcher, Joachim [5 ]
机构
[1] Univ Jena, Dept Internal Med 3, D-07747 Jena, Germany
[2] Univ Jena, Inst Diagnost & Intervent Radiol, D-07747 Jena, Germany
[3] Univ Jena, Inst Anat 1, D-07740 Jena, Germany
[4] Sudharz Klin Nordhausen, Dept Radiol, D-99734 Nordhausen, Germany
[5] SRH Wald Klinikum Gera, Inst Diagnost & Intervent Radiol, D-07548 Gera, Germany
关键词
Computer-aided diagnosis; Computer-aided joint space analysis; Joint space width; Rheumatoid arthritis; Osteoarthritis; COMPUTER-BASED METHODS; X-RAY RADIOGRAMMETRY; RHEUMATOID-ARTHRITIS; HAND RADIOGRAPHS; AGE; PERFORMANCE; UPDATE; TRIAL; SEX;
D O I
10.1007/s00296-010-1468-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study is to evaluate technical feasibility based on image capturing conditions (film-focus distance (FFD), film sensitivity, film brand, exposure level and tube voltage) that potentially alter radiographs and consequently may influence the semi-automated measurement of joint space distance (JSD) by computer-aided joint space analysis (CAJSA) in rheumatoid arthritis and osteoarthritis. The radiographs of a left hand (deceased man) were acquired under systematically changing image capturing conditions (exposure level: 4-8 mAs; FFD: 90-130 cm; film sensitivity: 200/400 and tube voltage: 40-52 kV with different image modalities: conventional radiographs, original digital radiographs, digital print-outs). All JSD-measurements were performed with the CAJSA-technology (Radiogrammetry Kit, Version 1.3.6; Sectra; Sweden) at the metacarpal-phalangeal articulation. JSD-analysis was not influenced by changes of FFD, exposure level, film sensitivity or film brand. JSD showed significant variation caused by tube voltage (conventional: CV = 1.913% for Agfa and CV = 2.448% for Kodak; digital: CV = 0.741% for Philips print-outs and CV = 0.620% with original digital images versus CV = 2.185% for Siemens print-outs and 0.951% with original digital images). Computer-aided joint space analysis for JSD-measurements is unaffected by the following image capturing parameters: film-focus distance, film sensitivity, film brand and exposure level. An influence of tube voltage was detected in a lesser extent for original digital images compared to the printed digital as well as conventional versions. Consequently, a standardized tube voltage is essential for accurate reproductions of CAJSA-measurements in rheumatoid arthritis and osteoarthritis.
引用
下载
收藏
页码:1349 / 1354
页数:6
相关论文
共 50 条
  • [41] Asbestos fiber length and width comparison between manual and semi-automated measurements
    Lee, Taekhee
    Barone, Teresa
    Rubinstein, Elaine
    Mischler, Steven
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2022, 19 (06) : 370 - 380
  • [42] Feasibility of a semi-automated approach to grading point of care ultrasound image generation skills
    Chen, Zizui
    Shehata, Mohamed S.
    Gong, Minglun
    Carnahan, Heather
    Dubrowski, Adam
    Smith, Andrew
    2015 INTERNATIONAL CONFERENCE ON IMAGE AND VISION COMPUTING NEW ZEALAND (IVCNZ), 2015,
  • [43] Utility of Semi-Automated Quantification of Perivascular Space in Routinely Collected MRI Sequences
    Fukuda, Andrew
    DeLuca, Emily
    Schwartz, Daniel
    Gonsalves, Meghan
    Swearingen, Hannah
    Luther, Madison
    Silbert, Lisa
    Carpenter, Linda
    Barredo, Jennifer
    BIOLOGICAL PSYCHIATRY, 2023, 93 (09) : S248 - S248
  • [44] Validation study of a semi-automated program for quantification of atherosclerotic burden
    Choi, Brian G.
    Novoselsky, Constantin A.
    Vilahur, Gemma
    Viles-Gonzalez, Juan F.
    Zafar, M. Urooj
    Ibanez, Borja
    Fuster, Valentin
    Badimon, Juan J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (03) : 615 - 620
  • [45] Semi-automated brain responses in communication: A magnetoencephalographic hyperscanning study
    Takano, Kazuyoshi
    Watanabe, Hayato
    Yagyu, Kazuyori
    Shimojo, Atsushi
    Boasen, Jared
    Murakami, Yui
    Shiraishi, Hideaki
    Yokosawa, Koichi
    Saito, Takuya
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 2893 - 2896
  • [46] Evaluation of full-automated pretreatment step versus semi-automated methods for tacrolimus and cyclosporine measurements
    Alomaim, W.
    Sumaily, K. M.
    Jawad, J. Abdel
    Otaibi, N.
    Dawoud, S. A.
    Alyaeesh, R.
    Alsanie, G.
    Mahmoud, S.
    Shebani, M.
    Alhamad, A.
    Rodriguez, J.
    Tamimi, W.
    CLINICA CHIMICA ACTA, 2022, 530 : S284 - S284
  • [47] Measurement of Upper-Limb Joint Angular Kinematics: A Comparative Study in Manual and Semi-automated Assembly Line
    Abreu, Ana Betty
    Santos, Joana
    Baptista, Joao
    SHO2015: INTERNATIONAL SYMPOSIUM ON OCCUPATIONAL SAFETY AND HYGIENE, 2015, : 1 - 3
  • [48] Quantification of fat in the posterior sacroiliac joint region applying a semi-automated segmentation method
    Poilliot, Amelie
    Tannock, Murray
    Zhang, Ming
    Zwirner, Johann
    Hammer, Niels
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 191
  • [49] A SEMI-AUTOMATED 3-D ANNOTATION METHOD FOR BREAST ULTRASOUND IMAGING: SYSTEM DEVELOPMENT AND FEASIBILITY STUDY ON PHANTOMS
    Jiang, Wei-wei
    Li, An-hua
    Zheng, Yong-Ping
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (02): : 434 - 446
  • [50] QUALITY IMPROVEMENT BY SEMI-AUTOMATED BENCHMARKING OF A CORE OUTCOME INDICATOR SET IN INFLAMMATORY BOWEL DISEASE: A MULTICENTRIC FEASIBILITY STUDY
    Bossuyt, Peter
    Ebert, Didier
    Baert, Filip J.
    Hoelkens, Eveline
    Huys, Inge
    Lembrechts, Nikki
    De Jonckere, Evva
    Dewint, Pieter
    Pouillon, Lieven
    GASTROENTEROLOGY, 2021, 160 (06) : S356 - S356