Feasibility study of semi-automated measurements of finger joint space widths

被引:6
|
作者
Pfeil, Alexander [1 ]
Sommerfeld, Julia [2 ]
Froeber, Rosemarie [3 ]
Lehmann, Gabriele [1 ]
Malich, Ansgar [4 ]
Hansch, Andreas [2 ]
Wolf, Gunter [1 ]
Boettcher, Joachim [5 ]
机构
[1] Univ Jena, Dept Internal Med 3, D-07747 Jena, Germany
[2] Univ Jena, Inst Diagnost & Intervent Radiol, D-07747 Jena, Germany
[3] Univ Jena, Inst Anat 1, D-07740 Jena, Germany
[4] Sudharz Klin Nordhausen, Dept Radiol, D-99734 Nordhausen, Germany
[5] SRH Wald Klinikum Gera, Inst Diagnost & Intervent Radiol, D-07548 Gera, Germany
关键词
Computer-aided diagnosis; Computer-aided joint space analysis; Joint space width; Rheumatoid arthritis; Osteoarthritis; COMPUTER-BASED METHODS; X-RAY RADIOGRAMMETRY; RHEUMATOID-ARTHRITIS; HAND RADIOGRAPHS; AGE; PERFORMANCE; UPDATE; TRIAL; SEX;
D O I
10.1007/s00296-010-1468-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study is to evaluate technical feasibility based on image capturing conditions (film-focus distance (FFD), film sensitivity, film brand, exposure level and tube voltage) that potentially alter radiographs and consequently may influence the semi-automated measurement of joint space distance (JSD) by computer-aided joint space analysis (CAJSA) in rheumatoid arthritis and osteoarthritis. The radiographs of a left hand (deceased man) were acquired under systematically changing image capturing conditions (exposure level: 4-8 mAs; FFD: 90-130 cm; film sensitivity: 200/400 and tube voltage: 40-52 kV with different image modalities: conventional radiographs, original digital radiographs, digital print-outs). All JSD-measurements were performed with the CAJSA-technology (Radiogrammetry Kit, Version 1.3.6; Sectra; Sweden) at the metacarpal-phalangeal articulation. JSD-analysis was not influenced by changes of FFD, exposure level, film sensitivity or film brand. JSD showed significant variation caused by tube voltage (conventional: CV = 1.913% for Agfa and CV = 2.448% for Kodak; digital: CV = 0.741% for Philips print-outs and CV = 0.620% with original digital images versus CV = 2.185% for Siemens print-outs and 0.951% with original digital images). Computer-aided joint space analysis for JSD-measurements is unaffected by the following image capturing parameters: film-focus distance, film sensitivity, film brand and exposure level. An influence of tube voltage was detected in a lesser extent for original digital images compared to the printed digital as well as conventional versions. Consequently, a standardized tube voltage is essential for accurate reproductions of CAJSA-measurements in rheumatoid arthritis and osteoarthritis.
引用
收藏
页码:1349 / 1354
页数:6
相关论文
共 50 条
  • [1] Feasibility study of semi-automated measurements of finger joint space widths
    Alexander Pfeil
    Julia Sommerfeld
    Rosemarie Fröber
    Gabriele Lehmann
    Ansgar Malich
    Andreas Hansch
    Gunter Wolf
    Joachim Böttcher
    [J]. Rheumatology International, 2011, 31 : 1349 - 1354
  • [2] Semi-Automated Quantification of Finger Joint Space Narrowing Using Tomosynthesis in Patients with Rheumatoid Arthritis
    Ichikawa, Shota
    Kamishima, Tamotsu
    Sutherland, Kenneth
    Kasahara, Hideki
    Shimizu, Yuka
    Fujimori, Motoshi
    Yasojima, Nobutoshi
    Ono, Yohei
    Kaneda, Takahiko
    Koike, Takao
    [J]. JOURNAL OF DIGITAL IMAGING, 2017, 30 (03) : 369 - 375
  • [3] Semi-Automated Quantification of Finger Joint Space Narrowing Using Tomosynthesis in Patients with Rheumatoid Arthritis
    Shota Ichikawa
    Tamotsu Kamishima
    Kenneth Sutherland
    Hideki Kasahara
    Yuka Shimizu
    Motoshi Fujimori
    Nobutoshi Yasojima
    Yohei Ono
    Takahiko Kaneda
    Takao Koike
    [J]. Journal of Digital Imaging, 2017, 30 : 369 - 375
  • [4] SENSITIVITY TO CHANGE AND VALIDITY OF SEMI-AUTOMATED JOINT SPACE WIDTH MEASUREMENTS IN HAND OSTEOARTHRITIS: A FOLLOW-UP STUDY
    Damman, W.
    Kortekaas, M. C.
    Stoel, B. C.
    van 't Klooster, R.
    Rosendaal, F. R.
    Kloppenburg, M.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2015, 23 : A203 - A203
  • [5] Semi-automated crater depth measurements
    Breton, Sylvain
    Quantin-Nataf, Cathy
    Bodin, Thomas
    Loizeau, Damien
    Volat, Matthieu
    Lozac'h, Loic
    [J]. METHODSX, 2019, 6 : 2293 - 2304
  • [6] A feasibility proof of semi-automated software integration
    Kazakov, M
    Abdulrab, H
    [J]. Proceedings of the IASTED International Conference on Software Engineering, 2004, : 447 - 452
  • [7] Semi-automated digital image analysis of joint space width in knee radiographs
    J. E. Schmidt
    K. K. Amrami
    A. Manduca
    K. R. Kaufman
    [J]. Skeletal Radiology, 2005, 34 : 639 - 643
  • [8] Semi-automated digital image analysis of joint space width in knee radiographs
    Schmidt, JE
    Amrami, KK
    Manduca, A
    Kaufman, KR
    [J]. SKELETAL RADIOLOGY, 2005, 34 (10) : 639 - 643
  • [9] Perinephric hematoma: semi-automated quantification of volume on MDCT: a feasibility study
    Pedram Rezai
    Sandra Tochetto
    Mauricio Galizia
    Vahid Yaghmai
    [J]. Abdominal Imaging, 2011, 36 : 222 - 227
  • [10] Perinephric hematoma: semi-automated quantification of volume on MDCT: a feasibility study
    Rezai, Pedram
    Tochetto, Sandra
    Galizia, Mauricio
    Yaghmai, Vahid
    [J]. ABDOMINAL IMAGING, 2011, 36 (02): : 222 - 227