Outcomes Following Different Fixation Strategies of Neer Type IIB Distal Clavicle Fractures

被引:6
|
作者
Gutman, Michael J. [1 ]
Joyce, Christopher D. [1 ]
Patel, Manan S. [1 ]
Lazarus, Mark D. [1 ]
Horneff, John G. [1 ]
机构
[1] Thomas Jefferson Univ, Rothman Inst, Philadelphia, PA 19107 USA
来源
关键词
Clavicle fracture; Neer IIB distal clavicle fracture; Acromioclavicular separation; Hook plate; Locking plate; Bosworth screw; Suture repair; LOCKING PLATE; HOOK-PLATE; SCREW FIXATION;
D O I
10.22038/ABJS.2021.54472.2718
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Multiple surgical techniques for fixation of Neer type IIB distal clavicle fractures have been described without consensus on optimal treatment. The purpose of this study is to compare functional and radiographic results with surgical management of Neer type IIB distal clavicle fractures at a single institution. Methods: Sixty-three patients with acute Neer type IIB fractures treated operatively were evaluated. Patients with a minimum of two year follow up were included. Functional scores included American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation (SANE), Simple Shoulder Test (SST), and Likert patient satisfaction (1 to 5). Radiographs were assessed for osseous union and coracoclavicular (CC) distance. Results: Thirty-eight patients met inclusion with a mean follow-up of 5.3 years. Patients were divided into five groups based on fixation technique: suture-only CC fixation (n=6), CC screw fixation only (n=3), open reduction internal fixation (OR IF) without CC fixation (n=8), hook plate fixation (n=4), and ORIF with suture CC reconstruction (n=17). Outcome scores for the entire cohort were 91.8 for ASES, 90.2 for SANE, and 10.8 for STT. Patients with hook plates had significantly lower SANE score (p=0.016), but no other significant differences in functional, satisfaction, or radiographic outcomes were found between groups. Sixteen patients (42.1%) required reoperation. Conclusion: Treatment of Neer type IIB fractures via suture- only fixation, plate-only fixation, or a combination of both demonstrated satisfactory mid to long term outcomes. While implant removal was more common in the CC screw and ORIF groups, no fixation technique proved functionally superior.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [21] Clinical and Radiological Outcomes of Closed-Loop, Double Button, Coracoclavicular Fixation for Extralateral (Neer Type IIC) Fractures of the Distal Clavicle
    Panagopoulos, Andreas
    Tatani, Irini
    Kattou, Constantinos
    Kouzelis, Antonis
    Kolios, Kyprianos
    Athinodorou, Ioannis-Panagiotis
    Kokkalis, Zinon
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (05)
  • [22] Comparative analysis of a locking plate with an all-suture anchor versus hook plate fixation of Neer IIb distal clavicle fractures
    Seo, Joong-Bae
    Kwak, Kwon-young
    Yoo, Jae-Sung
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (03)
  • [23] Comparative analysis of arthroscopic-assisted Tight-rope technique and clavicular hook plate fixation in the treatment of Neer type IIB distal clavicle fractures
    Nie, Si
    Li, Hong-Bo
    Hua, Li
    Tang, Zhi-Ming
    Lan, Min
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [24] Comparative analysis of arthroscopic-assisted Tight-rope technique and clavicular hook plate fixation in the treatment of Neer type IIB distal clavicle fractures
    Si Nie
    Hong-Bo Li
    Li Hua
    Zhi-Ming Tang
    Min Lan
    BMC Musculoskeletal Disorders, 23
  • [25] Hook plate fixation of Neer type II distal clavicle fractures results in satisfactory patient-reported outcomes but complications and revisions are high
    Beisemann, Nils
    Spiller, Yannik M.
    Schnetzke, Marc
    Gruetzner, Paul Alfred
    Nolte, Philip-Christian
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [26] Hook plate fixation of Neer type II distal clavicle fractures results in satisfactory patient-reported outcomes but complications and revisions are high
    Nils Beisemann
    Yannik M. Spiller
    Marc Schnetzke
    Paul Alfred Grützner
    Philip-Christian Nolte
    BMC Musculoskeletal Disorders, 24
  • [27] What is the optimal surgical treatment for Neer type IIB (IIC) distal clavicle fractures? A systematic review and meta-analysis
    Andreas Panagopoulos
    Konstantina Solou
    Irini Tatani
    Ioannis K. Triantafyllopoulos
    John Lakoumentas
    Antonis Kouzelis
    Vasileios Athanasiou
    Zinon T. Kokkalis
    Journal of Orthopaedic Surgery and Research, 17
  • [28] Comparison of the efficacy of a distal clavicular locking plate with and without a suture anchor in the treatment of Neer IIb distal clavicle fractures
    Hua Xu
    Wen Jun Chen
    Xiao Cheng Zhi
    Shi Chang Chen
    BMC Musculoskeletal Disorders, 20
  • [29] Treatment of unstable distal clavicle fractures (Neer type IIb): a modified system using a miniature locking plate with a single button
    Ying, Hua
    Wang, Jihuan
    Sun, Yuehua
    Dai, Kerong
    Yu, Chao
    Yang, Fei
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (06)
  • [30] Comparison of the efficacy of a distal clavicular locking plate with and without a suture anchor in the treatment of Neer IIb distal clavicle fractures
    Xu, Hua
    Chen, Wen Jun
    Zhi, Xiao Cheng
    Chen, Shi Chang
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01) : 503