Simultaneous determinations of Cu, Cd and Pb in river-water samples by multielement isotope dilution/ICP-MS with the aid of chelating resin preconcentration

被引:4
|
作者
Yamada, H
Ji, S
Itoh, A
Chiba, K
Haraguchi, H
机构
[1] Nagoya Univ, Grad Sch Engn, Dept Appl Chem, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, Waste Treatment Facil, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
river water; multielement isotope dilution analysis; ICP-MS; chelating resin preconcentration; copper; cadmium; lead;
D O I
10.2116/bunsekikagaku.50.433
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous determinations of Cu, Cd and Pb in river-water samples were investigated by multielement ID (isotope dilution)/ICP-MS (inductively coupled plasma mass spectrometry). A mixed and enriched spiked solution of Cu (Cu-63, 0.3%; Cu-65, 99.7%), Cd (Cd-110, 0.63%; Cd-111, 96.44%; Cd-112, 1.82%; Cd-113, 0.43%; Cd-114, 0.59%; Cd-116, 0.10%) and Pb (Pb-204, 0.0342%; Pb-206, 92.1497%; Pb-207, 6.5611%; Pb-208, 1.2550%) was added into the river-water samples, and kept standing overnight to achieve isotope equilibria. Since the concentrations of Cu, Cd and Pb in river water were extremely low, they were preconcentrated using a chelating resin (Chelex 100) at pH 9 before an isotope ratio measurement. The isotope ratios of Cu-63/Cu-65, Cd-114/Cd-111 and Pb-208/Pb-206 were then simultaneously measured for the spiked and standard solutions, respectively. Polyatomic ion interferences of (MoO)-Mo-95-O-16 and (MoO)-Mo-98-O-16 with Cd-111 and Cd-114, respectively, could be avoided by chelating resin preconcentration, because Mo was hardly recovered in the preconcentration, while Cd could be recovered by almost 100%. As a consequence, Cu, Cd and Pb in a river-water certified reference material (JAC 0031, issued from the Japan Society for Analytical Chemistry) and a river-water sample collected from the Kiso River were determined with fairly good precision by the present multielement ICP-MS method, simultaneously.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [1] Determination of Cadmium in Sea Water by ICP-MS with Chelating Resin Preconcentration
    Takaku, Yuichi
    Ishizuka, Kaori
    Nagaoka, Ayako
    Minakawa, Masayuki
    Morita, Takami
    Fujimoto, Ken
    BUNSEKI KAGAKU, 2016, 65 (07) : 399 - 402
  • [2] Simultaneous determination of trace elements in river-water samples by ICP-MS in combination with a discrete microsampling technique after enrichment with a chitosan-based chelating resin
    Lee, KH
    Oshima, M
    Takayanagi, T
    Motomizu, S
    ANALYTICAL SCIENCES, 2000, 16 (07) : 731 - 738
  • [3] Simultaneous Determination of Trace Elements in River-water Samples by ICP-MS in Combination with a Discrete Microsampling Technique after Enrichment with a Chitosan-based Chelating Resin
    Kyue-Hyung Lee
    Mitsuko Oshima
    Toshio Takayanagi
    Shoji Motomizu
    Analytical Sciences, 2000, 16 : 731 - 738
  • [4] FLOW-INJECTION ONLINE PRECONCENTRATION WITH CHELATING RESIN CPPI FOR MULTIELEMENT DETERMINATIONS IN WATER SAMPLES USING ICP-AES
    YANG, CL
    ZHUANG, ZX
    WANG, XR
    QIN, SD
    YANG, PY
    ATOMIC SPECTROSCOPY, 1994, 15 (03) : 135 - 139
  • [5] DOWNSIZED CHELATING RESIN-PACKED MINICOLUMN PRECONCENTRATION FOR MULTIELEMENT DETERMINATION OF TRACE METALS BY ICP-MS
    Rahmi, Dwinna
    MAKARA JOURNAL OF SCIENCE, 2010, 14 (02) : 121 - 128
  • [6] Multielement determination of trace metals in seawater by ICP-MS with aid of down-sized chelating resin-packed minicolumn for preconcentration
    Rahmi, Dwinna
    Zhu, Yanbei
    Fujimori, Eiji
    Umemura, Tomonari
    Haraguchi, Hiroki
    TALANTA, 2007, 72 (02) : 600 - 606
  • [7] Multielement determination of trace elements in river water certified reference materials (JAC 0031, JAC 0032) by ICP-MS and ICP-AES with chelating resin preconcentration
    Itoh, A
    Iwata, K
    Ji, S
    Yabutani, T
    Kimata, C
    Sawatari, H
    Haraguchi, H
    BUNSEKI KAGAKU, 1998, 47 (02) : 109 - 117
  • [8] Multielement determination of trace metals in seawater by ICP-MS using a chelating resin-packed minicolumn for preconcentration
    Zhu, YB
    Itoh, A
    Haraguchi, H
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2005, 78 (01) : 107 - 115
  • [9] Determination of V, Cr, Cu, As, and Pb Ions in Water and Biological Samples by Combining ICP-MS with Online Preconcentration Using Impregnated Resin
    Wang, Shuo
    Dong, Xv
    Dai, Bingye
    Pan, Mingfei
    He, Shaoyuan
    Wang, Junping
    JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (01) : 218 - 224
  • [10] Determination of Cd, Pb and Se in beef samples using aerosol dilution by ICP-MS
    Fiorella Iaquinta
    Lucimar Lopes Fialho
    Joaquim A. Nóbrega
    Mariela Pistón
    Ignacio Machado
    Journal of Food Measurement and Characterization, 2021, 15 : 4105 - 4111