Double-sided IPEM cooling using miniature heat pipes

被引:11
|
作者
Martens, TJ [1 ]
Nellis, GF [1 ]
Pfotenhauer, JM [1 ]
Jahns, TM [1 ]
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
基金
欧洲研究理事会; 美国国家科学基金会;
关键词
heat pipe; integrated power electronic module (IPEM); power electronics; thermal management;
D O I
10.1109/TCAPT.2005.848591
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Integrated power electronic module (IPEM) planar interconnect technologies offer opportunities for improved thermal management by allowing thermal access to the upper side of the power devices. In this paper, the feasibility of using miniature heat pipes to achieve effective double-sided cooling is investigated by analyzing the complete thermal circuit associated with the power device. A nominal case was modeled using the ANSYS(tm) finite element software in a single-sided and double-sided configuration. The numerical model predicted that the double-sided configuration would result in a 13 degrees C reduction in the maximum temperature compared to the single-sided case, for the same 100 W/cm(2) power dissipation in the semiconductor die. This corresponds to a 15% decrease in the maximum temperature rise relative to ambient or a similar increase in allowable power dissipation. Twenty-eight percent of the heat was removed from the upper side of the IPENI in the double-sided case. An additional benefit associated with double-sided cooling was a significant reduction in the spatial temperature gradients along the surface of the IPENI which would translate to lower thermally induced stress and higher reliability. The sensitivity of the numerical predictions to important parameters; including the dielectric conductivity, contact conductance, and heat sink characteristics are numerically investigated. An experimental fixture was fabricated and used to measure a miniature rectangular heat pipe's performance characteristics and the solder joint resistance at its evaporator and condenser interfaces in order to validate the numerical model inputs and demonstrate the required heat pipe capacity. The tested heat pipe was limited to approximately 80 W/cm(2) heat flux in a vertical, evaporator-over-condenser orientation. This limit was not observed in a vertical, gravity-assisted orientation for applied heat flux up to 125 W/cm(2). Equivalent heat pipe resistances of approximately 0.12 and 0.08 K/W were measured in these orientations, respectively. The contact resistance of the indium solder joint was measured and found to be approximately 0.1 cm(2.)K/W.
引用
收藏
页码:852 / 861
页数:10
相关论文
共 50 条
  • [21] Double-sided liquid cooling for power semiconductor devices using embedded power packaging
    Charboneau, BC
    Wang, F
    van Wyk, JD
    Boroyevich, D
    Liang, Z
    Scott, EP
    Tipton, CW
    CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 1138 - 1143
  • [22] Double-sided cooling for high power IGBT modules using flip chip technology
    Gillot, C
    Schaeffer, C
    Massit, C
    Meysenc, L
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2001, 24 (04): : 698 - 704
  • [23] Double-sided cooling for high power IGBT modules using flip chip technology
    Gillot, C
    Schaeffer, C
    Ferret, R
    Massit, C
    Meysenc, L
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 3016 - 3020
  • [24] Double-sided liquid cooling for power semiconductor devices using Embedded Power packaging
    Charboneau, Bryan C.
    Wang, Fei
    van Wyk, Jacobus Daniel
    Boroyevich, Dushan
    Liang, Zhenxian
    Scott, Elaine P.
    Tipton, C. Wesley
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (05) : 1645 - 1655
  • [25] Miniature loop heat pipes - A promising means for cooling electronics
    Maydanik, YF
    Vershinin, SV
    Korukov, MA
    Ochterbeck, JM
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2005, 28 (02): : 290 - 296
  • [26] Miniature loop heat pipes - A promising means for cooling electronics
    Maydanik, YF
    Vershinin, SV
    Korukov, MA
    Ochterbeck, JM
    ITHERM 2004, VOL 2, 2004, : 60 - 66
  • [27] An analytical model of thermal performance for an eccentric heat source on a rectangular plate with double-sided convective cooling
    Zhang, Jianxin
    Yan, Huifen
    Li, Yuqiang
    Niu, Pingjuan
    Yang, Qingxin
    AIP ADVANCES, 2019, 9 (02)
  • [28] Numerical study of the flow and heat transfer characteristics within the annular fuel element with double-sided cooling
    Wu, Mingting
    Zhou, Yunlong
    Huang, Na
    Yang, Jingming
    ANNALS OF NUCLEAR ENERGY, 2024, 199
  • [29] DOUBLE-SIDED DEWATERING
    WIGHTMAN, WS
    TAPPI, 1977, 60 (01): : 150 - 151
  • [30] DOUBLE-SIDED PHOTOLITHOGRAPHY
    HEINZ, RA
    CHUSS, JT
    SCHROEDER, CM
    SOLID STATE TECHNOLOGY, 1978, 21 (08) : 55 - 60