Numerical and experimental investigation on seismic behavior of the linked column steel braced frame system with energy-dissipating link beam at column base

被引:4
|
作者
Zhang, Ji [1 ]
Zhao, Baocheng [1 ]
Ge, Jun [1 ]
Chen, Xin [1 ]
Gu, Qiang [1 ]
机构
[1] Suzhou Univ Sci & Technol, Sch Civil Engn, 1701 Binhe Rd, Suzhou 215011, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Linked column steel braced frame system; Seismic performance; Failure mechanism; Laboratory experiments; DISPLACEMENT-BASED DESIGN;
D O I
10.1016/j.jobe.2022.105002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The linked column braced frame (LCBF) system features a braced frame system coupled with the linked column. The interior column base was uplifted and connected to the ground via an additional link to further improve link ductility and energy dissipating capability. Low cyclic loading tests were conducted on a three-story, one-bay, one-third-scale specimen. Results showed that plastic hinging was successfully limited to the links for a wide drift range. Damaged links were replaced with another type, and system performance was regained. The specimen was loaded again until structural failure, which was induced by damages occurred in links and fixed column bases. Hysteretic curves were plump for both link types, system lateral stiffness degraded slowly, and high bearing capacity was maintained during the whole loading process. Parametric analyses were then conducted numerically based on models validated by test data. The length of link with web stiffener was recommended to be within (1.0-1.5)M-p/V-p, where M-p and V-p were the plastic moment and plastic shear force, respectively. Experimental and numerical results have demonstrated the proposed LCBF system not only with high bearing capacity and significant energy dissipation, but also capable of achieving performance objectives including rapid return to occupancy and collapse prevention.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Experimental investigation on the seismic behavior of reinforced concrete column-steel beam subassemblies
    Xiong, Liquan
    Men, Jinjie
    Ren, Ruyue
    Lei, Mengke
    STEEL AND COMPOSITE STRUCTURES, 2018, 28 (04): : 471 - 482
  • [22] Experimental Investigation for Secant Stiffness and Energy-Dissipating Capacity Improvement Results of the RC Column Reinforced by AFL
    Zou Youlin
    Huang Peiyan
    MATERIALS SCIENCE, CIVIL ENGINEERING AND ARCHITECTURE SCIENCE, MECHANICAL ENGINEERING AND MANUFACTURING TECHNOLOGY, PTS 1 AND 2, 2014, 488-489 : 501 - 504
  • [23] Experiment Study on the Hysteretic Performance of a Novel Replaceable Beam-to-Column Joint with Energy-Dissipating Steel Hinge
    Ma, Yongchao
    Qi, Ai
    Yan, Guiyun
    Zheng, Lianqiong
    Xue, Panrong
    BUILDINGS, 2022, 12 (08)
  • [24] Experimental and numerical investigation on cyclic behavior of beam-to-column - to - column connection with a lateral steel slit damper
    Kmal, Mustafa Kais
    Zareei, Seyed Alireza
    Jaber, Firas Khairy
    Birzhandi, Mohammad Sadegh
    STRUCTURES, 2024, 69
  • [25] Experimental and Nonlinear Finite Element Analysis on Seismic Behavior of SRC Column and Steel Beam Planar Frame
    Li, Fengge
    Zhao, Gentian
    Li, Fengyun
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 1495 - +
  • [26] Experimental Investigation on Link Column Frame System for Reinforced Concrete Structures
    Shelton, J. Joel
    Hemalatha, G.
    Venkatesh, R.
    FACING THE CHALLENGES IN STRUCTURAL ENGINEERING, 2018, : 446 - 459
  • [27] Seismic behavior of linked column system as a steel lateral force resisting system
    Jaberi, Vahid
    Asghari, Abazar
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [28] Seismic Behavior of PC Column and Steel Beam Composite Moment Frame with Posttensioned Connection
    Wu, Yuntian
    Xiao, Yan
    Anderson, J. C.
    JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (11) : 1398 - 1407
  • [29] Experimental Investigation of the Progressive Collapse of a Steel Special Moment-Resisting Frame and a Post-tensioned Energy-Dissipating Frame
    Tsitos, Antonios
    Mosqueda, Gilberto
    ROLE OF SEISMIC TESTING FACILITIES IN PERFORMANCE-BASED EARTHQUAKE ENGINEERING, 2012, 22 : 367 - 382