Numerical and experimental investigation on seismic behavior of the linked column steel braced frame system with energy-dissipating link beam at column base

被引:4
|
作者
Zhang, Ji [1 ]
Zhao, Baocheng [1 ]
Ge, Jun [1 ]
Chen, Xin [1 ]
Gu, Qiang [1 ]
机构
[1] Suzhou Univ Sci & Technol, Sch Civil Engn, 1701 Binhe Rd, Suzhou 215011, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Linked column steel braced frame system; Seismic performance; Failure mechanism; Laboratory experiments; DISPLACEMENT-BASED DESIGN;
D O I
10.1016/j.jobe.2022.105002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The linked column braced frame (LCBF) system features a braced frame system coupled with the linked column. The interior column base was uplifted and connected to the ground via an additional link to further improve link ductility and energy dissipating capability. Low cyclic loading tests were conducted on a three-story, one-bay, one-third-scale specimen. Results showed that plastic hinging was successfully limited to the links for a wide drift range. Damaged links were replaced with another type, and system performance was regained. The specimen was loaded again until structural failure, which was induced by damages occurred in links and fixed column bases. Hysteretic curves were plump for both link types, system lateral stiffness degraded slowly, and high bearing capacity was maintained during the whole loading process. Parametric analyses were then conducted numerically based on models validated by test data. The length of link with web stiffener was recommended to be within (1.0-1.5)M-p/V-p, where M-p and V-p were the plastic moment and plastic shear force, respectively. Experimental and numerical results have demonstrated the proposed LCBF system not only with high bearing capacity and significant energy dissipation, but also capable of achieving performance objectives including rapid return to occupancy and collapse prevention.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Investigation on Seismic Performance of the Fully Assembled Steel Frame Applying Beam-Column Joints with Replaceable Energy-Dissipating Elements
    Zhang, Dawei
    Li, Yuanqi
    Huang, Binhui
    SUSTAINABILITY, 2023, 15 (06)
  • [2] Seismic performance of prefabricated beam-to-column joint with replaceable energy-dissipating steel hinge
    Zheng, Lian-Qiong
    Chen, Xiao-Yang
    Wei, Chang-Gui
    Yan, Gui-Yun
    BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (03) : 1865 - 1895
  • [3] Seismic performance of prefabricated beam-to-column joint with replaceable energy-dissipating steel hinge
    Lian-Qiong Zheng
    Xiao-Yang Chen
    Chang-Gui Wei
    Gui-Yun Yan
    Bulletin of Earthquake Engineering, 2022, 20 : 1865 - 1895
  • [4] Effect of column flexural characteristic on seismic behavior of braced frame with fixed column base
    Kimura, Y.
    MacRae, G. A.
    Stessa 2006, 2006, : 437 - 443
  • [5] Seismic response of linked column steel braced frame with mechanical springs
    Li, Feng
    Zhao, Bao-Cheng
    Li, Ying-Min
    Wang, Guo-Jue
    STRUCTURES, 2023, 53 : 240 - 252
  • [6] Experimental Study on Novel Energy-Dissipating Prefabricated Beam-Column Joints
    Liu, Qiong
    Chen, Shanghong
    Lin, Wei
    Zeng, Fanjin
    ADVANCES IN CIVIL ENGINEERING, 2019, 2019
  • [7] Evaluation on Seismic Performance of Beam-Column Joints of Fabricated Steel Structure with Replaceable Energy-Dissipating Elements
    Li, Yuanqi
    Huang, Binhui
    SUSTAINABILITY, 2022, 14 (06)
  • [8] Numerical Investigation of the Seismic Performance of Steel Frames with Energy-Dissipating Composite Walls
    Wei, Ding
    Suizi, Jia
    MATERIALS, 2022, 15 (03)
  • [9] Seismic Design and Behavior of Self-Centering Braced Frame with Controlled Rocking and Energy-Dissipating Fuses
    Stanford University
  • [10] Experimental and numerical investigations on novel post-tensioned precast beam-to-column energy-dissipating connections
    Wang, Shuguang
    Zhang, Tianyang
    Xu, Weizhi
    Du, Dongsheng
    Zhang, Yunlong
    STRUCTURES, 2023, 54 : 117 - 133