Residual Voltage Tests in Zinc Oxide (ZnO) Surge Arrester of 69kV

被引:0
|
作者
Mesquita, Daniel de Bastos [1 ]
de Souza Silva, Joao Lucas [1 ]
Moreira, Hugo Soeiro [1 ]
Villalva, Marcelo Gradella [1 ]
机构
[1] Univ Campinas UNICAMP, Sch Elect & Comp Engn FEEC, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
ZnO Surge Arrester; Residual Voltage Tests; Current Impulse Generator;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Equipment such as surge arresters are subject to various setbacks due to their exposure to adverse weather conditions. As a consequence of these setbacks, leaks of currents towards the ground can occur and cause accidents. In this way, high voltage tests are important to ensure the reliability of the equipment in the electrical system. As a benchmark for testing, IEC 60099-4 establishes the minimum reliability criteria for the operation of the surge arrester. In this context, the objective of this work is to perform Residual Voltage Tests in Zinc Oxide (ZnO) Surge Arrester of 69 kV and to compare the results with the data provided by the manufacturer which are based on the minimum criteria of IEC 60099-4. The methodology to obtain the results consisted in the measurement of residual voltage in the ZnO surge arrester the 69 kV for a current discharge of 5 kA and 10 kA using a Current Impulse Generator based on a Voltage Atmospheric Voltage Generator model SGD and reference data supplied by the manufacturer as well as the IEC 60099-4 standard. The measured residual voltage values were higher than the values guaranteed by the manufacturer according to the reference data. According to IEC 60099-4, the surge arrester can not be considered reliable and therefore is not capable of operating.
引用
收藏
页码:319 / 323
页数:5
相关论文
共 44 条
  • [21] Study On-Line Monitoring Method of 35KV Zinc Oxide Surge Arrester with Gap based on Lightning Impulse Characteristic
    Zhou, Yangxuan
    Zhou, Lixing
    [J]. 2017 INTERNATIONAL CONFERENCE ON SMART CITY AND SYSTEMS ENGINEERING (ICSCSE 2017), 2017, : 36 - 40
  • [22] Analysis of the Operational Effect of 500kV Line Zinc Oxide Arrester
    Zhao Shaofeng
    Gao Hongliang
    [J]. 2012 POWER ENGINEERING AND AUTOMATION CONFERENCE (PEAM), 2012, : 307 - 310
  • [23] Heat transfer analysis of metal oxide surge arrester under power frequency applied voltage
    Seyyedbarzegar, Seyyed Meysam
    Mirzaie, Mohammad
    [J]. ENERGY, 2015, 93 : 141 - 153
  • [24] The effect of aluminium oxide on the residual voltage of ZnO varistors
    Houabes, M
    Bernik, S
    Talhi, C
    Bui, A
    [J]. CERAMICS INTERNATIONAL, 2005, 31 (06) : 783 - 789
  • [25] Transient Electric Field Calculation of Zinc oxide arrester under Lightning Impulse Voltage
    Zhou, Shiyi
    Wang, Haoran
    Tian, Huidong
    Wu, Zehua
    Cheng, Jianwei
    Liu, Peng
    Peng, Zongren
    [J]. 2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 231 - 234
  • [26] Research on line ZnO surge arrester without supporting series gap for 500kV AC power transmission line
    Hui, YJ
    Cai, DK
    Hu, Z
    Xiao, Y
    Qiu, DF
    [J]. PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2004, : 419 - 422
  • [27] Grading Structure Design of Surge Arrester for 1000-kV Ultra-high Voltage Air-insulated Substation
    He, Jinliang
    Hu, Jun
    Zhang, Bo
    [J]. ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 84 - 87
  • [28] Application of high voltage gradient zinc oxide elements to SF6 gas insulated surge arresters for 22 kV 765 kV power systems
    Shirakawa, S
    Ejiri, I
    Watahiki, S
    Iimura, N
    Nakano, S
    Yamada, S
    Kondo, S
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (02) : 419 - 424
  • [29] Improved zinc oxide surge arresters using high voltage gradient 300 V/mm, 400 V/mm ZnO elements
    Shirakawa, S
    Yamada, S
    Tanaka, S
    Ejiri, I
    Watahiki, S
    Kondo, S
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (02) : 569 - 574
  • [30] Experimental Research on Residual Voltage Characteristics of 10kV Entire Arrester Under 8/20 μs Impulse Current
    Yu Wenbo
    Cai Li
    Wang Jianguo
    Fan Yadong
    Xiao Yutong
    Zou Xin
    [J]. 2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,