Comparison of Alaris AEP index and bispectral index during propofol-remifentanil anaesthesia

被引:45
|
作者
Kreuer, S
Bruhn, J
Larsen, R
Hoepstein, M
Wilhelm, W [1 ]
机构
[1] Univ Saarland, Dept Anaesthesiol & Intens Care Med, D-66421 Homburg, Germany
[2] Univ Bonn, Dept Anaesthesiol & Intens Care Med, D-53119 Bonn, Germany
关键词
anaesthetics i.v; propofol; analgesics opioid; remifentanil; equipment; AEP monitor; monitoring; bispectral index; electroencephalogram;
D O I
10.1093/bja/aeg189
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The Alaris AEP monitor(TM) (Alaris, UK, version 1.4) is the first commercially available auditory evoked potential (AEP) monitor designed to estimate the depth of anaesthesia. It generates an 'Alaris AEP index' (AAI), which is a dimensionless number scaled from 100 (awake) to 0. This study was designed to compare AAI and BIS(TM) (Aspect, USA, version XP) values at different levels of anaesthesia. Methods. Adult female patients were premedicated with diazepam 0.15 mg kg(-1) orally on the morning of surgery. Electrodes for BIS and Alaris AEP monitoring and a headphone to give auditory stimuli were applied as recommended by the manufacturers. Anaesthesia was induced with remifentanil (0.4 mug kg(-1) min(-1)) and a propofol target-controlled infusion (Diprifusor(TM) TCI, AstraZeneca, Germany) to obtain a predicted concentration of initially 3.5 mug ml(-1). After loss of consciousness the patients were given 0.5 mg kg(-1) of atracurium. After tracheal intubation, remifentanil was given at 0.2 mug kg(-1) min(-1) and the propofol infusion was adjusted to obtain BIS target values of 30, 40, 50, and 60. AAI and BIS values were recorded and matched with the predicted propofol effect-site concentrations. Prediction probability was calculated for consciousness vs unconsciousness. Values are mean (sd). Results. Fifty female patients, 53 (15), range 18-78 yr, ASA I or II were studied. Mean values before induction of anaesthesia were 95 (4), range 99-82 for BIS and 85 (12), range 99-55 for AAI. With loss of eyelash reflex both values were significantly reduced to 64 (13), range 83-39 for BIS (P<0.05) and 61 (22), range 99-15 for AAI (P<0.05). The prediction probability P-K for consciousness vs unconsciousness (i.e. loss of eyelash reflex) was better for BIS (P-K=0.99) than for AAI (P-K=0.79). At a BIS of 30, 40, 50, and 60 the corresponding AAI values were 15 (6), 20 (8), 28 (11), and 40 (16), and these were significantly different. Conclusions. During propofol-remifentanil anaesthesia a decrease of the depth of anaesthesia as indicated by BIS monitoring is accompanied by corresponding effects shown by the AAI. However, wide variation in the awake values and considerable overlap of AAI values between consciousness and unconsciousness, suggests further improvement of the AAI system is required.
引用
收藏
页码:336 / 340
页数:5
相关论文
共 50 条
  • [31] Effects of fentanyl, alfentanil, remifentanil and sufentanil on loss of consciousness and bispectral index during propofol induction of anaesthesia
    Lysakowski, C
    Dumont, L
    Pellégrini, M
    Clergue, F
    Tassonyi, E
    BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (04) : 523 - 527
  • [32] Comparison of propofol-alfentanil and propofol-remifentanil anaesthesia in percutaneous nephrolithotripsy
    Cicek, M
    Koroglu, A
    Demirbilek, S
    Teksan, H
    Ersoy, MO
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2005, 22 (09) : 683 - 688
  • [33] Impact of Bispectral Index for monitoring propofol remifentanil anaesthesia. A randomised clinical trial
    Bresil, P.
    Nielsson, M. S.
    Malver, L. P.
    Kraemer, K.
    Schjorring, O.
    Dethlefsen, C.
    Lambert, P. H.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2013, 57 (08) : 978 - 987
  • [34] Narcotrend® and Bispectral Index® monitor are superior to classic electroencephalographic parameters for the assessment of anesthetic states during propofol-remifentanil anesthesia
    Schmidt, GN
    Bischoff, P
    Standl, T
    Jensen, K
    Voigt, M
    Esch, JSA
    ANESTHESIOLOGY, 2003, 99 (05) : 1072 - 1077
  • [35] Bispectral index and state entropy of the electroencephalogram during propofol anaesthesia
    Bonhomme, V. L.
    Hans, P. C.
    BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (01) : 145 - 146
  • [36] Effect of high dose remifentanil on bispectral index during propofol anesthesia
    Yasuhiro, Morimoto
    3RD WORLD CONGRESS OF TOTAL INTRAVENOUS ANAESTHESIA & TARGET CONTROLLED INFUSION, 2011, : 73 - 76
  • [37] Comparison of Entropy and Bispectral Index during Propofol and Fentanyl Sedation in Monitored Anaesthesia Care
    Balci, C.
    Karabekir, H. S.
    Kahraman, F.
    Sivaci, R. G.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2009, 37 (05) : 1336 - 1342
  • [38] Impact of patient age on propofol consumption during propofol-remifentanil anaesthesia
    Kreuer, S
    Schreiber, JU
    Bruhn, J
    Wilhelm, W
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2005, 22 (02) : 123 - 128
  • [39] Tramadol does not modify the Bispectral Index during anaesthesia with sevoflurane and remifentanil
    Fodale, V
    Praticò, C
    Tescione, M
    Tanania, S
    Lucanto, T
    Santamaria, LB
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (02) : 212 - 215
  • [40] Spectral entropy measurement of patient responsiveness during propofol and remifentanil. A comparison with the bispectral index
    Vanluchene, ALG
    Struys, MMRF
    Heyse, BEK
    Mortier, EP
    BRITISH JOURNAL OF ANAESTHESIA, 2004, 93 (05) : 645 - 654