Calibration and Optimization of an Insertion Electromagnetic Flowmeter With the Aid of Numerical Analysis

被引:1
|
作者
Ma, Haibo [1 ]
Ma, Shilei [2 ]
Moss, Robert [2 ]
Fisher, Mark [2 ]
Silaen, Armin K. [1 ]
Zhou, Chenn Q. [1 ]
机构
[1] Purdue Univ Northwest, Ctr Innovat Visualizat & Simulat CIVS, Hammond, IN 46323 USA
[2] Dwyer Instruments, Michigan City, IN 46360 USA
关键词
computational foundations for engineering optimization; computer aided design; computer aided engineering; multiphysics modeling and simulation; physics-based simulations; MAGNETIC-FIELD DATA; VELOCITY PROFILE; 2-PHASE FLOW; LAMINAR-FLOW; SLUG FLOW; COMPUTATION; SIMULATIONS; PREDICTION; METER;
D O I
10.1115/1.4052579
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Accurate measurement of the volumetric flowrate of working liquids is essential for process control, as well as energy consumption evaluation. Electromagnetic flowmeters have gained popularity in applications where low-pressure drop and low maintenance are required. Dwyer Instruments, Inc. recently developed an adjustable insertion electromagnetic flowmeter (IEF) featuring accurate and reliable measurement. However, unexpected and non-repeatable behavior in the K-factor was observed during the calibration process. The K-factor is the coefficient used to convert the measured electric potential to the flow velocity in pipes, and the non-repeatable behavior imposes challenges for precise measurement. A one-way coupled magnetohydrodynamics model was developed to reduce the effort and time of onsite troubleshooting and optimization. By modeling the measurement process, the transition of flow regimes and the regeneration of the boundary layer on the electrode surface were identified as the causes of the non-repeatable issue. Then, a series of parametric studies were performed to provide reliable solutions. A new design with further embedded electrodes to allow the smooth transition between boundary layers was recommended. The field test showed excellent repeatability by using the new design, and the non-repeatable issue was entirely resolved. The improvement in the IEF design was implemented in production in less than one week, and it reduced the calibration time by 50%.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Solving weight function for the partially filled pipe electromagnetic flowmeter by means of finite element numerical analysis
    Wei, Kaixia
    Gu, Shulong
    He, Longqing
    [J]. ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 3395 - 3399
  • [32] CALIBRATION METHOD FOR ELECTROMAGNETIC-FLOWMETER USING CROSS-CORRELATION OF VOLTAGE FLUCTUATIONS
    ENDOU, A
    ASAKURA, F
    MATSUNO, Y
    NOMOTO, S
    [J]. PROGRESS IN NUCLEAR ENERGY, 1982, 9 : 95 - 105
  • [33] Weighting Function-Based Coil Size Optimization for Electromagnetic Flowmeter
    Xu, Lijun
    Peng, Zhicong
    Cao, Zhang
    Ling, Qi
    Wang, Gang
    [J]. 2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 705 - 710
  • [34] An alternative analysis method for evaluating electromagnetic flowmeter performance
    Beck, Kade J.
    Barfuss, Steven L.
    Sharp, Zachary B.
    Moon, Todd K.
    [J]. AWWA WATER SCIENCE, 2021, 3 (05):
  • [35] Design and optimisation of electromagnetic flowmeter for conductive liquids and its calibration based on neural networks
    Hooshmand, R. A.
    Joorabian, M.
    [J]. IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2006, 153 (04) : 139 - 146
  • [36] Numerical analysis of the electromagnetic force for design optimization of a rectangular direct current electromagnetic pump
    Lee, Geun Hyeong
    Kim, Hee Reyoung
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2018, 50 (06) : 869 - 876
  • [37] Numerical Solution for Weight Function of Electromagnetic Flowmeter Using Finite Element Method
    Wei, Kaixia
    [J]. ADVANCES IN COMPUTATIONAL MODELING AND SIMULATION, PTS 1 AND 2, 2014, 444-445 : 1360 - 1363
  • [38] Failure Modes Analysis of Electromagnetic Flowmeter Based on Grey Relational Analysis
    Zhou, Z.
    Li, L. B.
    Qin, Y.
    Ma, D. Z.
    Niu, B.
    [J]. ADVANCES IN FUNCTIONAL MANUFACTURING TECHNOLOGIES, 2010, 33 : 322 - 326
  • [40] THE DESIGN AND OPTIMIZATION OF A NEW BLUFF BODY OF THE ELECTROMAGNETIC VORTEX FLOWMETER BASED ON ISIGHT
    Xu He
    Li Zhen
    Xu Yixian
    Yu Hongpeng
    [J]. INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 4, 2016,