Hydrophilic interaction liquid chromatography coupled to mass spectrometry-based detection to determine emerging organic contaminants in environmental samples

被引:40
|
作者
Salas, Daniela [1 ]
Borrull, Francesc [1 ]
Fontanals, Nuria [1 ]
Maria Marce, Rosa [1 ]
机构
[1] Univ Rovira & Virgili, Dept Analyt Chem & Organ Chem, Campus Sescelades,Marcelli Domingo S-N, E-43007 Tarragona, Spain
关键词
Hydrophilic interaction liquid chromatography; Mass spectrometry; Emerging organic contaminants; Environmental samples; HILIC stationary phases; HILIC mobile phases; SOLID-PHASE EXTRACTION; METHYLAMINO-L-ALANINE; WASTE-WATER; STATIONARY PHASES; ARTIFICIAL SWEETENERS; REVERSED-PHASE; FRESH-WATER; TRANSFORMATION PRODUCTS; CONTRAST AGENTS; INTERACTION LC;
D O I
10.1016/j.trac.2017.07.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrophilic interaction liquid chromatography (HILIC) has gained widespread acceptance as an alternative to reversed-phase liquid chromatography (RPLC) for the retention and separation of polar compounds. Because a great number of emerging organic contaminants are polar, this represents progress in terms of solving most of the problems and limitations encountered in the conventional methods developed for their determination. In this review, recent HILIC applications developed in the environmental field are described, which are normally coupled with mass spectrometry, in order to reach the limits required to quantify contaminants present at trace levels and benefit from its capacity for confirmation. Special attention is paid to the stationary and mobile phases commonly used in terms of the advantages that they offer compared to reversed-phase columns and the high-water content mobile phases traditionally used in RPLC. The most important features related to the matrices and contaminants normally studied are also discussed, as well as the contribution of the HILIC mode towards reducing the matrix effect. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 50 条
  • [21] Systematic comparison of sensitivity between hydrophilic interaction liquid chromatography and reversed phase liquid chromatography coupled with mass spectrometry
    Periat, Aurelie
    Boccard, Julien
    Veuthey, Jean-Luc
    Rudaz, Serge
    Guillarme, Davy
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1312 : 49 - 57
  • [22] Application of hydrophilic interaction chromatography for the analysis of polar contaminants in food and environmental samples
    van Nuijs, Alexander L. N.
    Tarcomnicu, Isabela
    Covaci, Adrian
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (35) : 5964 - 5974
  • [23] Discrepancies in determination of biogenic amines in beer samples by reversed phase and hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry
    Nalazek-Rudnicka, Katarzyna
    Kubica, Pawel
    Wasik, Andrzej
    MICROCHEMICAL JOURNAL, 2020, 159
  • [24] HYDROPHILIC INTERACTION LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Ji, Hye Young
    Park, Eun Jung
    Chang, Bo Yoon
    Kim, Sung Yeon
    Lee, Hye Suk
    DRUG METABOLISM REVIEWS, 2008, 40 : 45 - 45
  • [25] Investigation of the oxidative transformation of roxarsone by electrochemistry coupled to hydrophilic interaction liquid chromatography/mass spectrometry
    Frensemeier, Lisa M.
    Buter, Lars
    Vogel, Martin
    Karst, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 153 - 161
  • [26] Simultaneous analysis of multiple neurotransmitters by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry
    Tufi, Sara
    Lamoree, Marja
    de Boer, Jacob
    Leonards, Pim
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1395 : 79 - 87
  • [27] Hydrophilic Interaction Liquid Chromatography Coupled with Mass Spectrometry for Serum Metabolomics Analysis of Bladder Cancer
    Zheng Si-Jia
    Wang Qing-Qing
    Wang Xiao-Lin
    Zhao Xin-Jie
    Xu Guo-Wang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (12) : 1921 - 1929
  • [28] Determination of Oxidized Phosphatidylcholines by Hydrophilic Interaction Liquid Chromatography Coupled to Fourier Transform Mass Spectrometry
    Sala, Pia
    Poetz, Sandra
    Brunner, Martina
    Troetzmueller, Martin
    Fauland, Alexander
    Triebl, Alexander
    Hartler, Juergen
    Lankmayr, Ernst
    Koefeler, Harald C.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2015, 16 (04): : 8351 - 8363
  • [29] Application of hydrophilic interaction liquid chromatography coupled with mass spectrometry in the analysis of phosphorothioate oligonucleotides in serum
    Studzinska, Sylwia
    Lobodzinski, Filip
    Buszewski, Boguslaw
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1040 : 282 - 288
  • [30] Achievements and future trends in the analysis of emerging organic contaminants in environmental samples by mass spectrometry and bioanalytical techniques
    Farre, Marinella
    Kantiani, Lina
    Petrovic, Mira
    Perez, Sandra
    Barcelo, Damia
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 : 86 - 99