Partial Discharge Localization in Transformers Using UHF Sensors

被引:0
|
作者
Sinaga, H. H. [1 ]
Phung, B. T. [1 ]
Ao, P. L. [1 ]
Blackburn, T. R. [1 ]
机构
[1] Univ New S Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
关键词
Partial discharge location; Ultra High Frequency (UHF); cumulative energy;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The location of the partial discharge (PD) source inside a transformer can be determined by using the time differences between signals that are captured by an array of three UHF sensors. However, other unwanted signals are also picked up by the sensors and may result in a false PD location. This paper discusses the application of multivariate denoising to the PD signals. Three methods are compared to determine the time difference between the received signals and locate the PD source. With the first peak method, the time difference is calculated by taking the first peak of the signal as the arrival instant. In the second method, the arrival time is determined from the knee point of the cumulative energy curve. For the third method, the time difference is determined by applying the similarity function to the plot of the cumulative energy of the PD signals. The last method is fully automated. However, experimental results show the first peak method tends to be the most accurate.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 50 条
  • [31] GIS partial discharge quantitative measurements using UHF microstrip antenna sensors
    Tang Ju
    Xu Zhongrong
    Zhang Xiaoxing
    Sun Caixin
    [J]. 2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 116 - 119
  • [32] Application of UHF Method for Partial Discharge Source Location in Power Transformers
    Dukanac, Djordje
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (06) : 2266 - 2278
  • [33] Analysis on Partial Discharge Localization Using UHF Combined with Acoustic Method in GIS
    Liu, Junhua
    Huang, Chengjun
    Qian, Yong
    Jiang, Xiuchen
    [J]. INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (03): : 1266 - 1270
  • [34] Partial discharge localization on dry-type transformers
    Szczechowski, Janusz
    Siodla, Krzysztof
    [J]. 2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [35] Partial Discharge Localization in Power Transformers Using Invariant Extended Kalman Filter
    Al-Masri, Wasim
    Wadi, Ali
    Abdel-Hafez, Mamoun F. F.
    Hashim, Hashim A. A.
    El-Hag, Ayman H. H.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [36] Partial Discharge Localization in Transformers Using Detailed Modeling of Winding and Calibration Pulses
    Jafari, A. Mazhab
    Akbari, A.
    Kharezi, M.
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 536 - +
  • [37] Partial Discharge Localization in Power Transformers Using Neuro-Fuzzy Technique
    Homaei, Mohammad
    Moosavian, Seyed Mahdi
    Illias, Hazlee Azil
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (05) : 2066 - 2076
  • [38] Investigating practical experiments of partial discharge localization in transformers using winding modeling
    Jafari, A. Mazhab
    Akbari, A.
    Mirzaei, H. R.
    Kharezi, M.
    Allahbakhshi, M.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (04) : 1174 - 1182
  • [39] Application of Time Difference of Arrival Methods in the Localization of Partial Discharge Sources Detected Using Bio-Inspired UHF Sensors
    Xavier, George V. R.
    de Oliveira, Adriano C.
    Silva, Allan D. C.
    Nobrega, Luiz A. M. M.
    da Costa, Edson G.
    Serres, Alexandre J. R.
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (02) : 1947 - 1956
  • [40] The Location of Partial Discharge Source in the Power Transformer with UHF Sensors
    Xue, Naifan
    Yang, Junjie
    [J]. 2018 5TH INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2018, : 261 - 265