Spatial charge effects in retarding field analyzer ion measurements in a cathodic vacuum arc

被引:6
|
作者
Grondona, D [1 ]
Kelly, H [1 ]
Márquez, A [1 ]
机构
[1] Univ Buenos Aires, Fac Ciencias Exactas & Nat, Dept Fis, CONICET,Inst Fis Plasma, RA-1428 Buenos Aires, DF, Argentina
关键词
D O I
10.1063/1.1380402
中图分类号
O59 [应用物理学];
学科分类号
摘要
The ion energy distribution generated in a pulsed vacuum arc operated with a Ti cathode and N-2 filling gas is reported. A retarding field analyzer system is employed, for which the usual derivation of the ion energy spectrum has been modified to take into account spatial charge effects in the grid-collector region of the analyzer. It allows one to interpret the decrease in the collector current at collector bias voltages unusually low (even negatives) observed in this experiment, as well as in others. It is found that spatial charge effects are more marked when the arc operates with gas filling because of the creation (by charge-exchange processes) of low energy gaseous ions which are easily stopped by the potential hump created by the positive charge in the grid-collector region of the analyzer. (C) 2001 American Institute of Physics.
引用
收藏
页码:317 / 319
页数:3
相关论文
共 50 条
  • [21] Ion angle distribution measurement with a planar retarding field analyzer
    Sharma, Shailesh
    Gahan, David
    Scullin, Paul
    Daniels, Stephen
    Hopkins, M. B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (11):
  • [22] The influence of impurities on ion temperature measured by a retarding field analyzer
    Shao, J.
    Liu, Hai
    Xu, Yuhong
    Huang, Jie
    Liu, Haifeng
    Wang, Xianqu
    Zhang, Xin
    Cheng, Jun
    Tang, Changjian
    PLASMA PHYSICS AND CONTROLLED FUSION, 2020, 62 (02)
  • [23] Space-charge compensation measurements in electron cyclotron resonance ion source low energy beam transport lines with a retarding field analyzer
    Winklehner, D.
    Leitner, D.
    Cole, D.
    Machicoane, G.
    Tobos, L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [24] Simultaneous ion temperature and flow measurements using a retarding field analyzer in the HL-2A tokamak
    Kreuger, K.
    Huang, Z. H.
    Jiang, M.
    Xu, G. S.
    Zhang, W.
    Wang, H. Q.
    Cheng, J.
    Hong, W. Y.
    Yan, L. W.
    Xiao, C.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2013, 168 (10): : 776 - 788
  • [25] Ion Temperature Measurements in the Tore Supra Scrape-Off Layer Using a Retarding Field Analyzer
    Kocan, M.
    Gunn, J. P.
    Pascal, J. -Y.
    Gauthier, E.
    CONTRIBUTIONS TO PLASMA PHYSICS, 2010, 50 (09) : 836 - 840
  • [26] First ion temperature measurements in the MAST-U divertor via Retarding Field Energy Analyzer
    Damizia, Y.
    Elmore, S.
    Ryan, P.
    Allan, S.
    Federici, F.
    Osborne, N.
    Bradley, J. W.
    NUCLEAR MATERIALS AND ENERGY, 2025, 43
  • [27] Metal ion implantation using a filtered cathodic vacuum arc
    Bilek, MMM
    Evans, P
    Mckenzie, DR
    McCulloch, DG
    Zreiqat, H
    Howlett, CR
    JOURNAL OF APPLIED PHYSICS, 2000, 87 (09) : 4198 - 4204
  • [28] Absolute measurements of rf fields using a retarding field energy analyzer
    Charles, C.
    Degeling, A.
    Sheridan, T.
    Harris, J.
    Boswell, R.
    Lieberman, M.
    IEEE International Conference on Plasma Science, 2000,
  • [29] Measurements of the electron temperature fluctuations with a retarding field analyzer on the tokamak ISTTOK
    Nedzelskiy, I. S.
    Silva, C.
    Fernandes, H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (09):
  • [30] Spatially resolved electron temperature measurements with a microfabricated retarding field analyzer
    Sowa, MJ
    Blain, MG
    Jarecki, RL
    Stevens, JE
    APPLIED PHYSICS LETTERS, 2002, 80 (06) : 932 - 934