High-performance liquid chromatographic determination of oxalic acid in tea using tris(1,10-phenanthroline)-ruthenium(II) chemiluminescence

被引:17
|
作者
Wu, FW [1 ]
He, Z [1 ]
Luo, QY [1 ]
Zeng, Y [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
oxalic acid; chemiluminescence; Ru(phen)(3)(2+); high-performance liquid chromatography; tea;
D O I
10.2116/analsci.14.971
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chemiluminescence (CL) of Ru(phen)(3)(2+) was applied to HPLC determination of oxalic acid, which was separated by a C-18 reverse-phase column with a mobile phase of 0.02 mol/l NH4Ac, mixed with 0.25 mol/l Ru(phen)(3)(2+) and 2.0 mmol/l Ce(SO4)(2) (0.08 mol/l H2SO4), and then passed through a homemade CL detector. The reaction of Ce(IV)oxidized Ru(phen)(3)(2+) and the oxalic acid emitted light. The detection limit was 6.2x10(-6) mol/l for oxalic acid at a S/N ratio of 3, the relative standard deviation for 5 replicate injections of 1x10(-3) mol/l oxalic acid standard was calculated as 5.6%, and the linear calibration range was 1x10(-5) to 4x10(-3) mol/l. The method was successfully applied to determination of oxalic acid in tea.
引用
收藏
页码:971 / 973
页数:3
相关论文
共 50 条
  • [31] LUMINESCENCE QUENCHING OF TRIS(2,2'-BIPYRIDINE)RUTHENIUM(II) AND TRIS(1,10-PHENANTHROLINE)RUTHENIUM(II) CATIONS
    DEMAS, JN
    ADDINGTON, JW
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1976, 98 (19) : 5800 - 5806
  • [32] A three-dimensional net of Δ-tris(1,10-phenanthroline)ruthenium(II) in the dual-metal self-assembly of bis[tris(1,10-phenanthroline) ruthenium(II)] tetraisothiocyanatoiron (bis(perchlorate)
    Ghazzali, Mohamed
    Ohrstrom, Lars
    Lincoln, Per
    Langer, Vratislav
    ACTA CRYSTALLOGRAPHICA SECTION C-STRUCTURAL CHEMISTRY, 2008, 64 (07): : M243 - M245
  • [33] Flow-injection chemiluminescent determination of estrogen benzoate using the tris(1,10-phenanthroline) ruthenium(II)-permanganate system
    Ma, Yan
    Cao, Wei
    Qiao, Shuang
    Liu, Wenwen
    Yang, Jinghe
    LUMINESCENCE, 2011, 26 (06) : 579 - 584
  • [34] SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN-PEROXIDE USING TRIS(1,10-PHENANTHROLINE)IRON(II)
    AFSAR, H
    APAK, R
    TOR, I
    ANALYST, 1990, 115 (01) : 99 - 103
  • [35] TRIS(1,10-PHENANTHROLINE)RUTHENIUM(II)-SENSITIZED AND TRIS(2,2'-BIPYRAZINE)RUTHENIUM(II)-SENSITIZED PHOTOPOLYMERIZATION OF ACRYLAMIDE
    IWAI, K
    UESUGI, Y
    SAKABE, T
    HAZAMA, C
    TAKEMURA, F
    POLYMER JOURNAL, 1991, 23 (06) : 757 - 763
  • [36] CHROMATOGRAPHIC RESOLUTION OF CYCLIC ORGANIC-COMPOUNDS ON A LAMBDA-TRIS(1,10-PHENANTHROLINE)RUTHENIUM(II) MONTMORILLONITE COLUMN
    YAMAGISHI, A
    OHNISHI, R
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1983, 22 (02): : 162 - 163
  • [37] Electron transfer kinetics of tris(1,10-phenanthroline)ruthenium(II) electrooxidation in aprotic solvents
    Winkler, K
    McKnight, N
    Fawcett, WR
    JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (15): : 3575 - 3580
  • [38] Use of 1,10-Phenanthroline as an Additive for High-Performance Supercapacitors
    Borenstein, A.
    Hershkovitz, S.
    Oz, A.
    Luski, S.
    Tsur, Y.
    Aurbach, D.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2015, 119 (22): : 12165 - 12173
  • [39] Determination of pholcodine in syrups and human plasma using the chemiluminescence system of tris(1,10 phenanthroline)ruthenium(II) and acidic Ce(IV)
    Delouei, Nastaran Jafari
    Mokhtari, Ali
    Jamali, Mohammad Reza
    LUMINESCENCE, 2017, 32 (03) : 387 - 393
  • [40] Enhancement of on chip chemiluminescence signal intensity of tris(1,10-phenanthroline)-ruthenium(II) peroxydisulphate system for analysis of chlorpheniramine maleate in pharmaceutical formulations
    Al Lawati, Haider A. J.
    Suliman, Fakhr Eldin O.
    Al Kindy, Salma M. Z.
    Al-Lawati, Ali M.
    Varma, Gouri B.
    Nour, Imad Eldin M.
    TALANTA, 2010, 82 (05) : 1999 - 2002