GSU Transformer - Current Transformer Connections and Differential Relay Applications

被引:0
|
作者
Hansen, Daniel J. [1 ]
机构
[1] NRG Energy Inc, Princeton, NJ 08540 USA
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The application and connection of current transformers for electromechanical differential circuits creates vulnerability for mis-operation under rare but identified scenarios. As a lesson learned from a real-world incident, discovery of the vulnerability occurred during the investigation of a generating unit trip from a nearby switchyard fault immediately outside a generator step-up transformer (GSU) differential zone of protection. Problem resolution is correctable or minimized with the available features of microprocessor differential relays, with sufficient winding inputs, and the proper application of current transformer connections. However, shortcuts in the design and installation of new circuits and microprocessor relays can introduce similar vulnerabilities.
引用
收藏
页码:393 / 400
页数:8
相关论文
共 50 条
  • [31] Modeling and implementing of a proposed electronic differential relay for transformer protection
    Ashour, HA
    [J]. ICEEC'04: 2004 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONIC AND COMPUTER ENGINEERING, PROCEEDINGS, 2004, : 795 - 799
  • [32] A FIRANN as a differential relay for three phase power transformer protection
    Orille-Fernández, AL
    Ghonaim, NKI
    Valencia, JA
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (02) : 215 - 218
  • [33] Adaptive digital differential relay of parabolic characteristic for transformer protection
    Maheshwari, RP
    Verma, HK
    [J]. ELECTRIC MACHINES AND POWER SYSTEMS, 1997, 25 (05): : 459 - 473
  • [34] Power Transformer Protection Using a Multiregion Adaptive Differential Relay
    Dashti, Hamed
    Sanaye-Pasand, Majid
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) : 777 - 785
  • [35] Using Iop characteristics to troubleshoot transformer differential relay misoperation
    Thompson, M
    Closson, JR
    [J]. NETA: TECHNICAL CONFERENCE PAPERS, 2001, : 3 - 21
  • [36] A MULTICRITERIA DIFFERENTIAL TRANSFORMER RELAY BASED ON FUZZY-LOGIC
    WISZNIEWSKI, A
    KASZTENNY, B
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (04) : 1786 - 1792
  • [37] Distance relay suitable for use with a measurement type current transformer
    Lee, Hyun-Woong
    Kang, Yong-Cheol
    Jang, Sung-Il
    Kim, Yong-Gyun
    [J]. 2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1176 - +
  • [38] The Impact Analysis of Current Transformer's Saturation to Relay Protection
    Xu, Ningting
    Dong, Jun
    Zheng, Siyuan
    [J]. 2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [39] An experience with transformer connections and relay settings for temporary generator step up unit
    Sutherland, Peter E.
    Parra, Carlos
    [J]. 2011 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (ICPS), 2011,
  • [40] Compensation of the current transformer saturation effects for transmission line fault location with impedance-differential relay
    Herlender, J.
    Izykowski, J.
    Solak, K.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2020, 182