Haemodynamics and stresses in abdominal aortic aneurysms: A fluid-structure interaction study into the effect of proximal neck and iliac bifurcation angle

被引:44
|
作者
Drewe, Corey J. [1 ,2 ,3 ]
Parker, Louis P. [1 ,2 ,3 ]
Kelsey, Lachlan J. [1 ,2 ,3 ]
Norman, Paul E. [1 ,2 ,4 ]
Powell, Janet T. [5 ]
Doyle, Barry J. [1 ,2 ,3 ,6 ]
机构
[1] Univ Western Australia, QEII Med Ctr, Harry Perkins Inst Med Res, Vasc Engn Lab, Perth, WA, Australia
[2] Univ Western Australia, Ctr Med Res, Perth, WA, Australia
[3] Univ Western Australia, Sch Mech & Chem Engn, Perth, WA, Australia
[4] Univ Western Australia, Sch Surg, Perth, WA, Australia
[5] Imperial Coll London, Vasc Surg Res Grp, London, England
[6] Univ Edinburgh, BHF Ctr Cardiovasc Sci, Edinburgh, Midlothian, Scotland
基金
英国医学研究理事会;
关键词
Abdominal aortic aneurysm; Geometry; Wall stress; Wall shear stress; Fluid structure interaction; WALL STRESS; RUPTURE; RISK;
D O I
10.1016/j.jbiomech.2017.06.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Our knowledge of how geometry influences abdominal aortic aneurysm (AAA) biomechanics is still developing. Both iliac bifurcation angle and proximal neck angle could impact the haemodynamics and stresses within AAA. Recent comparisons of the morphology of ruptured and intact AAA show that cases with large iliac bifurcation angles are less likely to rupture than those with smaller angles. We aimed to perform fluid-structure interaction (FSI) simulations on a range of idealised AAA geometries to conclusively determine the influence of proximal neck and iliac bifurcation angle on AAA wall stress and haemodynamics. Peak wall shear stress (WSS) and time-averaged WSS (TAWSS) in the AAA sac region only increased when the proximal neck angle exceeded 30 degrees. Both peak WSS (p < 0.0001) and peak von Mises wall stress (p = 0.027) increased with iliac bifurcation angle, whereas endothelial cell activation potential (ECAP) decreased with iliac bifurcation angle (p < 0.001) and increased with increasing neck angle. These observations may be important as AAAs have been shown to expand, develop thrombus and rupture in areas of low WSS. Here we show that AAAs with larger iliac bifurcation angles have higher WSS, potentially reducing the likelihood of rupture. Furthermore, ECAP was lower in AAA geometries with larger iliac bifurcation angles, implying less likelihood of thrombus development and wall degeneration. Therefore our findings could help explain the clinical observation of lower rupture rates associated with AAAs with large iliac bifurcation angles. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:150 / 156
页数:7
相关论文
共 50 条
  • [21] Fluid-Structure Interaction Modeling of Ascending Thoracic Aortic Aneurysms in SimVascular
    Valente, Rodrigo
    Mourato, Andre
    Brito, Moises
    Xavier, Jose
    Tomas, Antonio
    Avril, Stephane
    BIOMECHANICS, 2022, 2 (02): : 189 - 204
  • [22] The effect of angulation in abdominal aortic aneurysms: fluid–structure interaction simulations of idealized geometries
    Michalis Xenos
    Yared Alemu
    Dan Zamfir
    Shmuel Einav
    John J. Ricotta
    Nicos Labropoulos
    Apostolos Tassiopoulos
    Danny Bluestein
    Medical & Biological Engineering & Computing, 2010, 48 : 1175 - 1190
  • [23] Ultrasound-Based Fluid-Structure Interaction Modeling of Abdominal Aortic Aneurysms Incorporating Pre-stress
    Fonken, Judith H. C.
    Maas, Esther J.
    Nievergeld, Arjet H. M.
    van Sambeek, Marc R. H. M.
    van de Vosse, Frans N.
    Lopata, Richard G. P.
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [24] A two-system, single-analysis, fluid-structure interaction technique for modelling abdominal aortic aneurysms
    Kelly, S. C.
    O'Rourke, M. J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H8) : 955 - 969
  • [25] Fluid-Structure Interaction Modeling of Abdominal Aortic Aneurysms: The Impact of Patient-Specific Inflow Conditions and Fluid/Solid Coupling
    Chandra, Santanu
    Raut, Samarth S.
    Jana, Anirban
    Biederman, Robert W.
    Doyle, Mark
    Muluk, Satish C.
    Finol, Ender A.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (08):
  • [26] Wall stress and flow dynamics in abdominal aortic aneurysms: finite element analysis vs. fluid-structure interaction
    Scotti, Christine M.
    Jimenez, Jorge
    Muluk, Satish C.
    Finol, Ender A.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2008, 11 (03) : 301 - 322
  • [27] Fluid-structure interaction analysis for abdominal aortic aneurysms: the role of multi-layered tissue architecture and intraluminal thrombus
    Yue, Xinhai
    Huang, Jiayi
    Liu, Ju
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2025, 13
  • [28] Fluid structure interaction study in model abdominal aortic aneurysms: Influence of shape and wall motion
    Philip, Nimmy Thankom
    Patnaik, B. S. V.
    B. J., Sudhir
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2021, 37 (03)
  • [29] The effect of aortic wall and aortic leaflet stiffening on coronary hemodynamic: a fluid-structure interaction study
    Nobari, S.
    Mongrain, R.
    Leask, R.
    Cartier, R.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (08) : 923 - 936
  • [30] Comparative study of arterial wall models for numerical fluid-structure interaction simulation of aortic arch aneurysms
    Ferreira da Silva, Mario Luis
    Goncalves, Saulo de Freitas
    Huebner, Rudolf
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2022, 44 (05)