Dependence of sensitisation of LiF:Mg,Ti (TLD-100) on the partial readout end temperature

被引:1
|
作者
Piters, TM
Yoshimura, EM
Okuno, E
Sunta, CM
Perez, R
Aceves, R
BarbozaFlores, M
机构
关键词
D O I
10.1093/oxfordjournals.rpd.a031622
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to obtain information about the deep traps which are responsible for the supralinear part of the dose response of peak 4 in the glow curve of LiF:Mg,Ti the pre-dose sensitisation of peak 4 was investigated. It is to be expected that peak 4 can be sensitised when the readout end temperature is lower than the emptying temperature of the deep traps. However, no sensitisation of peak 4 for readout end temperatures as low as 200 degrees C could be detected. This remarkable result is discussed with respect to a partly interactive trap system (PITS) model. It is shown that this model cannot explain the result. It can be explained when the PITS model is extended with an additional recombination centre with a low recombination probability.
引用
收藏
页码:207 / 210
页数:4
相关论文
共 50 条
  • [1] Some dosimetric characteristics of the high temperature TL in LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 203 - 207
  • [2] DEPENDENCE OF LIF TLD-100 RESPONSE ON TEMPERATURE DURING EXPOSURE
    SUNTA, CM
    MAZZARO, AC
    SORDI, GMAA
    WATANABE, S
    HEALTH PHYSICS, 1976, 30 (03): : 309 - 310
  • [3] Investigation of the ionisation density dependence of the glow curve characteristics of LIF:MG,TI (TLD-100)
    Horowitz, Y. S.
    Horowitz, A.
    Oster, L.
    Marino, S.
    Datz, H.
    Margaliot, M.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (04) : 406 - 413
  • [4] DOSE DEPENDENCE OF RADIATION INDUCED DAMAGE IN THE THERMOLUMINESCENT RESPONSE OF LIF:Mg,Ti (TLD-100)
    Reshes, G.
    Biderman, S.
    Horowitz, Y. S.
    Oster, L.
    Eliyahu, I.
    Ginsburg, D.
    Shapiro, A.
    Assor, Y.
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 232 - 237
  • [5] Characteristics of the high temperature thermoluminescence in LiF:Mg,Ti(TLD-100): The effects of batch history
    Datz, H.
    Horowitz, Y. S.
    Oster, L.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 710 - 712
  • [6] Influence of background subtraction protocol on the high temperature thermoluminescence in LiF:Mg,Ti (TLD-100)
    Datz, H.
    Horowitz, Y. S.
    Oster, L.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1440 - 1443
  • [7] The unified interaction model applied to LiF:Mg,Ti (TLD-100):: Properties of the luminescent and competitive centres during sensitisation
    Nail, I
    Horowitz, YS
    Oster, L
    Biderman, S
    RADIATION PROTECTION DOSIMETRY, 2002, 102 (04) : 295 - 304
  • [8] OPTICAL BLEACHING OF DEFECT CENTERS IN TLD-100 (LIF-MG, TI)
    MERKLIN, JF
    NUCLEAR INSTRUMENTS & METHODS, 1978, 157 (03): : 519 - 523
  • [9] Defect structure of glow peak 1 in LiF:Mg,Ti (TLD-100)
    Yazici, A. Necmeddin
    Turkish Journal of Physics, 2002, 26 (06): : 473 - 481
  • [10] Investigation of the emission spectra of LiF:Mg,Ti (TLD-100) during thermoluminescence
    Biderman, S
    Horowitz, Y
    Oster, L
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 369 - 372