Temperature-controlled laser photocoagulation of soft tissue: In vivo evaluation using a tissue welding model

被引:0
|
作者
Poppas, DP [1 ]
Stewart, RB [1 ]
Massicotte, M [1 ]
Wolga, AE [1 ]
Kung, RTV [1 ]
Retik, AB [1 ]
Freeman, MR [1 ]
机构
[1] ABIOMED INC,RES & DEV,DANVERS,MA 01923
关键词
porcine; skin; solder; tensile strength; thermal denaturation;
D O I
10.1002/(SICI)1096-9101(1996)18:4<335::AID-LSM2>3.0.CO;2-T
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objective: Laser surgical procedures involving photocoagulation of soft tissue have relied on subjective visual endpoints. The thermal damage to the denatured tissue in these procedures is highly dependent on the tissue temperatures achieved during laser irradiation. Therefore, a system capable of real time temperature monitoring and closed loop feedback was used to provide temperature controlled photocoagulation (TCPC). Study Design/Materials and Methods: The TCPC system consisted of a 1.32 mu m Nd:YAG laser, an infrared thermometer, and a microprocessor for data acquisition and feedback control. A porcine skin model was used. Tissue welds were completed to evaluate the photocoagulation effects at different predetermined temperatures. A quantitative measurement of tissue photocoagulation was obtained by tensile strength measurements of the laser repairs. Histology of the irradiated tissue was used to determine the extent of thermal injury associated with different photocoagulation temperatures. Results: The TCPC system was capable of maintaining a relatively constant temperature (+/-4 degrees C) during laser irradiation. The tensile strengths of acute repairs increased with temperature over the range studied (65-95 degrees C). Tensile measurements made after several days of healing showed that higher temperature (95 degrees C) welds had lower strengths than repairs completed at lower (65 degrees C or 75 degrees C) temperatures and were significantly lower at 3 days. Acute histology showed that the amount thermal damage was strongly dependent on the tissue temperature and increased both in tissue depth and lateral to the repair with temperature. The histologic results suggest that the increase in the acute repair tensile strength as the weld temperature increased was due to an increase in the depth of tissue photocoagulation. The increase in the lateral tissue injury measured histologically for higher temperature welds Likely resulted in the decreased chronic tensile strengths, as a healing response to excessive thermal damage. Conclusion: Tissue temperatures can be controlled during laser photocoagulation of skin. The degree of acute and chronic tissue damage is highly dependent on the temperature during welding. By controlling the tissue temperature during laser procedures, the surgical outcome can be more reliably predicted and reproduced, as compared to the conventional open loop methods. In addition, the use of a TCPC system should significantly reduce the learning curve for photothermal surgical procedures. (C) 1996 Wiley-Liss, Inc.
引用
收藏
页码:335 / 344
页数:10
相关论文
共 50 条
  • [11] Low temperature solder for laser tissue welding
    Lauto, A
    Stewart, RB
    Felsen, D
    Foster, J
    Poole-Warren, L
    Poppas, DP
    WINDOW ON THE LASER MEDICINE WORLD, 2003, 5287 : 83 - 90
  • [12] NIR-laser tissue welding in an in vivo guinea pig animal model
    Sriramoju, Vidyasagar
    Savage, Howard E.
    Katz, A.
    Chakraverty, Rahul
    Budansky, Yuri
    Podder, Rakhi
    Davatgarzadeh, Naghmeh
    Kartazayev, Uladzimir
    Rosen, Richard B.
    Alfano, R. R.
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XIX, 2008, 6854
  • [13] Additive Manufacturing for Tissue Engineering Applications in a Temperature-Controlled Environment
    Tseng, Wei-Chih
    Liao, Chao-Yaug
    Chen, Bo-Ren
    Chassagne, Luc
    Cagneau, Barthelemy
    2022 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2022, : 10201 - 10206
  • [14] In vivo laser tissue welding in the rabbit maxillary sinus
    Bleier, Benjamin S.
    Palmer, James N.
    Gratton, Michael A.
    Cohen, Noarn A.
    AMERICAN JOURNAL OF RHINOLOGY, 2008, 22 (06): : 625 - 628
  • [15] Rapid tissue processing using a temperature-controlled collection device to preserve tumor biomarkers
    Lerch, Melissa
    Kenerson, Heidi
    Theiss, Abbey
    Chafin, David
    Westerhoff, Maria
    Otter, Michael
    Yeung, Raymond
    Baird, Geoffrey
    CELL AND TISSUE BANKING, 2020, 21 (01) : 89 - 97
  • [16] Noninvasive determination of hemoglobin and hematocrit using a temperature-controlled localized reflectance tissue photometer
    Wu, XM
    Yeh, S
    Jeng, TW
    Khalil, OS
    ANALYTICAL BIOCHEMISTRY, 2000, 287 (02) : 284 - 293
  • [17] Rapid tissue processing using a temperature-controlled collection device to preserve tumor biomarkers
    Melissa Lerch
    Heidi Kenerson
    Abbey Theiss
    David Chafin
    Maria Westerhoff
    Michael Otter
    Raymond Yeung
    Geoffrey Baird
    Cell and Tissue Banking, 2020, 21 : 89 - 97
  • [18] Temperature controlled CO2 laser tissue welding of ocular tissues.
    Barak, A
    MaNaim, T
    Belkin, M
    Katzir, A
    OPHTHALMIC TECHNOLOGIES VII, PROCEEDINGS OF, 1997, 2971 : 103 - 105
  • [19] Reshapable polymeric hydrogel for controlled soft-tissue expansion: In vitro and in vivo evaluation
    Garner, John
    Davidson, Darrel
    Eckert, George J.
    Barco, Clark T.
    Park, Haesun
    Park, Kinam
    JOURNAL OF CONTROLLED RELEASE, 2017, 262 : 201 - 211
  • [20] In vitro and in vivo evaluation of orthopedic interface repair using a tissue scaffold with a continuous hard tissue-soft tissue transition
    Darryl A Dickerson
    Tarik N Misk
    David C Van Sickle
    Gert J Breur
    Eric A Nauman
    Journal of Orthopaedic Surgery and Research, 8