Fluorescence microlymphography: Diagnostic potential in lymphedema and basis for the measurement of lymphatic pressure and flow velocity

被引:0
|
作者
Bollinger, A. [1 ]
Amann-Vesti, B. R. [1 ]
机构
[1] Univ Zurich Hosp, Clin Angiol, CH-8091 Zurich, Switzerland
关键词
fluorescence microlymphography; lymphedema; Milroy disease; lymphatics; lymphatic pressure; lymphatic flow velocity; lymphangiogenesis; microangiopathy;
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Fluorescence microlymphography (FML) is an almost atraumatic technique used to visualize the superficial skin network of initial lymphatics through the intact skin of man. Visualization was performed with an incident light fluorescence microscope following subepidermal injection of minute amounts of FITC-dextran 150,000 using microneedles. Emanatingfrom the bright dye depot, the surrounding network of microvessels is filled, documentation performed by photography or video film. In congenital Milroy lymphedema, a lack of microlymphatics (aplasia) is typical while in other primary lymphedemas and in secondary lymphedema after mastectomy or irradiation of proximal lymph nodes, the network remains intact but the depicted area is enlarged. Lymphatic microangiopathy characterized by obliterations of capillary meshes or mesh segments develops in phleboedema with trophic skin changes, progressive systemic sclerosis and Fabry's disease. In lipedema, lymphatic microaneurysms are stained. Microlymphatic pressure may also be measured using FML. For this purpose, glass micropipettes are inserted into the capillaries by means of a micromanipulator and pressure is determined by the servo-nulling technique. Normal subjects produced significantly lower pressure (7.9 3.4 mmHg) compared to patients with primary lymphedema (15.0 +/- 5.1 mmHg, p<0.001). This characteristic lymphatic hypertension may be improved by complex physiotherapy or local application of prostaglandins. Additionally, a modification of the FML procedure can be used to measure lymphatic capillary flow velocity in controls and patients. FML is suited to confirm the clinical diagnosis of lymphedema, contributes to distinguish among various forms of edema, and is useful in clinical research. In addition, FML has also become a tool for experimental animal studies including the depiction of gastric microlymphatics, the measurement of flow velocity in the naked mouse tail, and in evaluation of lymphangiogenesis in a model of Milroy disease.
引用
收藏
页码:52 / 62
页数:11
相关论文
共 50 条
  • [31] Measurement and analysis of liquid film velocity in annular flow based on laser-induced fluorescence
    Xue, Ting
    Ge, Peng-Hui
    Yang, Liu-Xiang-Zi
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2015, 26 (03): : 523 - 528
  • [32] Influence of Branching and Tapering on Intracoronary Pressure and Flow Velocity: Comparison of Axial Measurement Location
    Nolte, F.
    Remmelink, M.
    van den Wijngaard, J. P.
    Zweers, S. J.
    Baan, J.
    Piek, J. J.
    Siebes, M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 1313 - 1316
  • [33] SIMULTANEOUS MEASUREMENT OF STATIC PRESSURE-FLUCTUATIONS AND VELOCITY FLUCTUATIONS IN TURBULENT LIQUID FLOW
    KURODA, C
    OGAWA, K
    INOUE, I
    KAGAKU KOGAKU RONBUNSHU, 1981, 7 (06) : 564 - 567
  • [34] The Study to Pressure and Flow Measurement for Hydraulic System on Basis of Non- inserting Technology
    An Ji
    Sun Yuqing
    Zhang Hongpeng
    Zhang Yindong
    2010 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-5, 2010, : 696 - 700
  • [35] Pressure-driven flow of a micro-polar fluid: Measurement of the velocity profile
    Peters, F.
    Lobry, L.
    Lemaire, E.
    JOURNAL OF RHEOLOGY, 2010, 54 (02) : 311 - 325
  • [36] MEASUREMENT OF BLOOD-PRESSURE, BLOOD-FLOW AND FLOW VELOCITY IN ARTERIAL RECONSTRUCTION OF THE LOWER-EXTREMITY
    SHIONOYA, S
    MATSUBARA, J
    HIRAI, M
    KAWAI, S
    SEKO, T
    SAKURAI, T
    BAN, I
    ANGIOLOGY, 1983, 34 (04) : 244 - 256
  • [37] PLANAR VELOCITY-MEASUREMENT IN SYMMETRICAL FLOW-FIELDS WITH LASER-INDUCED IODINE FLUORESCENCE
    HOLLO, SD
    HARTFIELD, RJ
    MCDANIEL, JC
    OPTICS LETTERS, 1994, 19 (03) : 216 - 218
  • [38] Assessment of coronary flow reserve by coronary pressure measurement - Comparison with flow- or velocity-derived coronary flow reserve
    Akasaka, T
    Yamamuro, A
    Kamiyama, N
    Koyama, Y
    Akiyama, M
    Watanabe, N
    Neishi, Y
    Takagi, T
    Shalman, E
    Barak, C
    Yoshida, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (09) : 1554 - 1560
  • [39] Inertial measurement unit as a tool within dense phase pneumatic conveying. Investigation into velocity measurement accuracy, pressure and velocity relationships in slug flow
    Lavrinec, A.
    Orozovic, O.
    Rajabnia, H.
    Williams, K.
    Jones, M. G.
    Klinzing, G.
    POWDER TECHNOLOGY, 2021, 382 : 454 - 466
  • [40] MEASUREMENT OF INSTANTANEOUS BLOOD FLOW VELOCITY AND INTRAVASCULAR PRESSURE IN CONSCIOUS HUMAN SUBJECTS BY A NEW TECHNIQUE
    GABE, IT
    MILLS, CJ
    MASON, DT
    GAULT, J
    ROSS, J
    BRAUNWAL.E
    SHILLING.JP
    CIRCULATION, 1968, 38 (4S6) : VI79 - &