Wide-field optical coherence micro-elastography for intraoperative assessment of human breast cancer margins

被引:82
|
作者
Allen, Wes M. [1 ,2 ]
Chin, Lixin [1 ,2 ]
Wijesinghe, Philip [1 ]
Kirk, Rodney W. [1 ,3 ]
Latham, Bruce [4 ]
Sampson, David D. [1 ,5 ]
Saunders, Christobel M. [6 ,7 ,8 ]
Kennedy, Brendan F. [1 ,2 ]
机构
[1] Univ Western Australia, Sch Elect Elect & Comp Engn, Opt Biomed Engn Lab, Perth, WA 6009, Australia
[2] QEII Med Ctr, Harry Perkins Inst Med Res, BRITElab, 6 Verdun St, Nedlands, WA 6009, Australia
[3] Univ ofAdelaide, Fac Hlth Sci, Ctr Nanoscale BioPhoton, Adelaide, SA 5005, Australia
[4] Fiona Stanley Hosp, PathWest, 11 Robin Warren Dr, Murdoch, WA 6150, Australia
[5] Univ Western Australia, Ctr Microscopy Characterisat & Anal, 35 Stirling Highway, Perth, WA 6009, Australia
[6] Univ Western Australia, Sch Surg, 35 Stirling Highway, Perth, WA 6009, Australia
[7] Fiona Stanley Hosp, Breast Ctr, 11 Robin Warren Dr, Murdoch, WA 6150, Australia
[8] Royal Perth Hosp, Breast Clin, 197 Wellington St, Perth, WA 6000, Australia
来源
BIOMEDICAL OPTICS EXPRESS | 2016年 / 7卷 / 10期
基金
英国医学研究理事会; 澳大利亚研究理事会;
关键词
CONSERVING SURGERY; SURGICAL MARGINS; RE-EXCISION; TOMOGRAPHY; PREDICTORS; RATES;
D O I
10.1364/BOE.7.004139
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Incomplete excision of malignant tissue is a major issue in breast-conserving surgery, with typically 20 - 30% of cases requiring a second surgical procedure arising from postoperative detection of an involved margin. We report advances in the development of a new intraoperative tool, optical coherence micro-elastography, for the assessment of tumor margins on the micro-scale. We demonstrate an important step by conducting whole specimen imaging in intraoperative time frames with a wide-field scanning system acquiring mosaicked elastograms with overall dimensions of similar to 50 x 50 mm, large enough to image an entire face of most lumpectomy specimens. This capability is enabled by a wide-aperture annular actuator with an internal diameter of 65 mm. We demonstrate feasibility by presenting elastograms recorded from freshly excised human breast tissue, including from a mastectomy, lumpectomies and a cavity shaving. (C)2016 Optical Society of America
引用
收藏
页码:4139 / 4153
页数:15
相关论文
共 50 条
  • [21] Intraoperative Use of Wide-Field Optical Coherence Tomography to Evaluate Tissue Microstructure in the Oral Cavity and Oropharynx
    Badhey, Arvind K.
    Schwarz, Julia S.
    Laitman, Benjamin M.
    Veremis, Brandon M.
    Westra, William H.
    Yao, Mike
    Teng, Marita S. S.
    Genden, Eric M.
    Miles, Brett A.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2023, 149 (01) : 71 - 78
  • [22] The wide-field multifocal electroretinogram and optical coherence tomography in the assessment of choroidal nevi and melanomas
    Muscat, S
    Parks, S
    Kemp, E
    Keating, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U251 - U251
  • [23] A Custom Wide-Field Spectral Imager For Breast Cancer Margin Assessment
    Dhar, Sulochana
    Lo, Justin Y.
    Yu, Bing
    Tyler, Talmage
    Brooke, Martin A.
    Ramanujam, Nimmi
    Jokerst, Nan M.
    Kuech, Thomas F.
    2011 IEEE PHOTONICS CONFERENCE (PHO), 2011, : 798 - +
  • [24] Optical coherence tomography (OCT) as a diagnostic tool for the real-time intraoperative assessment of breast cancer surgical margins
    Nguyen, F. T.
    Zysk, A. M.
    Chaney, E. J.
    Kotynek, J. G.
    Oliphant, U. J.
    Bellafiore, F. J.
    Rowland, K. M.
    Johnson, P. A.
    Boppart, S. A.
    CANCER RESEARCH, 2009, 69 (02) : 101S - 101S
  • [25] Diagnostic Accuracy of Quantitative Micro-Elastography for Margin Assessment in Breast-Conserving Surgery
    Kennedy, Kelsey M.
    Zilkens, Renate
    Allen, Wes M.
    Foo, Ken Y.
    Fang, Qi
    Chin, Lixin
    Sanderson, Rowan W.
    Anstie, James
    Wijesinghe, Philip
    Curatolo, Andrea
    Tan, Hsern Ern I.
    Morin, Narelle
    Kunjuraman, Bindu
    Yeomans, Chris
    Chin, Synn Lynn
    DeJong, Helen
    Giles, Katharine
    Dessauvagie, Benjamin F.
    Latham, Bruce
    Saunders, Christobel M.
    Kennedy, Brendan F.
    CANCER RESEARCH, 2020, 80 (08) : 1773 - 1783
  • [26] Optical Coherence Tomography The Intraoperative Assessment of Lymph Nodes in Breast Cancer
    Nguyen, Freddy T.
    Zysk, Adam M.
    Chaney, Eric J.
    Adie, Steven G.
    Kotynek, Jan G.
    Oliphant, Uretz J.
    Bellafiore, Frank J.
    Rowland, Kendrith M.
    Johnson, Patricia A.
    Boppart, Stephen A.
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2010, 29 (02): : 63 - 70
  • [27] Wide-Field Focused Microwave Ablation and Tumor Margins for Invasive Breast Cancer: A Progress Update
    Dooley, William C.
    Vargas, Hernan J.
    Fenn, Alan J.
    Tomaselli, Mary Beth
    Harness, Jay K.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2009, 32 (05): : 558 - 558
  • [28] THE STUDY ON THE RECONSTRUCTION ALGORITHMS FOR WIDE-FIELD OPTICAL COHERENCE TOMOGRAPHY
    Yang, Yongyong
    Jia, Jia
    Feng, Yinqi
    ADVANCES IN BIOMEDICAL PHOTONICS AND IMAGING, 2008, : 329 - 333
  • [29] WIDE-FIELD SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Gilardoni, Francesca
    Pichi, Francesco
    Bonsignore, Francesco
    Nucci, Paolo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [30] Wide-field optical coherence microscopy of the mouse brain slice
    Min, Eunjung
    Lee, Junwon
    Vavilin, Andrey
    Jung, Sunwoo
    Shin, Sungwon
    Kim, Jeehyun
    Jung, Woonggyu
    OPTICS LETTERS, 2015, 40 (19) : 4420 - 4423