Semi-automatic segmentation for prostate interventions

被引:57
|
作者
Mandavi, S. Sara [1 ]
Chng, Nick [1 ,2 ]
Spadinger, Ingrid [2 ]
Morris, William J. [3 ]
Salcudean, Septimiu E. [1 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
[2] British Columbia Canc Agcy, Dept Med Phys, Vancouver, BC V5Z 4E6, Canada
[3] British Columbia Canc Agcy, Dept Radiat Oncol, Vancouver, BC V5Z 4E6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Prostate interventions; Segmentation; Trans-rectal ultrasound imaging; Prostate brachytherapy; ACTIVE SHAPE MODELS; ULTRASOUND IMAGES; BOUNDARY SEGMENTATION; TRUS IMAGES; 2D; BRACHYTHERAPY;
D O I
10.1016/j.media.2010.10.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper we report and characterize a semi-automatic prostate segmentation method for prostate brachytherapy. Based on anatomical evidence and requirements of the treatment procedure, a warped and tapered ellipsoid was found suitable as the a-priori 3D shape of the prostate. By transforming the acquired endorectal transverse images of the prostate into ellipses, the shape fitting problem was cast into a convex problem which can be solved efficiently. The average whole gland error between non-overlapping volumes created from manual and semi-automatic contours from 21 patients was 6.63 +/- 0.9%. For use in brachytherapy treatment planning, the resulting contours were modified, if deemed necessary, by radiation oncologists prior to treatment. The average whole gland volume error between the volumes computed from semi-automatic contours and those computed from modified contours, from 40 patients, was 5.82 +/- 4.15%. The amount of bias in the physicians' delineations when given an initial semi-automatic contour was measured by comparing the volume error between 10 prostate volumes computed from manual contours with those of modified contours. This error was found to be 7.25 +/- 0.39% for the whole gland. Automatic contouring reduced subjectivity, as evidenced by a decrease in segmentation inter- and intra-observer variability from 4.65% and 5.95% for manual segmentation to 3.04% and 3.48% for semi-automatic segmentation, respectively. We characterized the performance of the method relative to the reference obtained from manual segmentation by using a novel approach that divides the prostate region into nine sectors. We analyzed each sector independently as the requirements for segmentation accuracy depend on which region of the prostate is considered. The measured segmentation time is 14 +/- 1 s with an additional 32 +/- 14s for initialization. By assuming 1-3 min for modification of the contours, if necessary, a total segmentation time of less than 4 min is required, with no additional time required prior to treatment planning. This compares favorably to the 5-15 min manual segmentation time required for experienced individuals. The method is currently used at the British Columbia Cancer Agency (BCCA) Vancouver Cancer Centre as part of the standard treatment routine in low dose rate prostate brachytherapy and is found to be a fast, consistent and accurate tool for the delineation of the prostate gland in ultrasound images. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:226 / 237
页数:12
相关论文
共 50 条
  • [31] Semi-automatic heuristic segmentation of fetal skull images
    Konur, Umut
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2023, 38 (02): : 679 - 692
  • [32] A novel framework for semi-automatic video object segmentation
    Li, N
    Li, SP
    Liu, WY
    Chen, C
    2002 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL III, PROCEEDINGS, 2002, : 811 - 814
  • [33] Semi-automatic single particle segmentation on electron micrographs
    Carvalho, Bruno M.
    Oliveira, Lucas M.
    Garduno, Edgar
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1024 - +
  • [34] SEMI-IMPLICIT SCHEME FOR SEMI-AUTOMATIC SEGMENTATION IN NATURASAT SOFTWARE
    Ambroz, Martin
    Kollar, Michal
    Mikula, Karol
    ALGORITMY 2020: 21ST CONFERENCE ON SCIENTIFIC COMPUTING, 2020, : 171 - 180
  • [35] Principles and methods for automatic and semi-automatic tissue segmentation in MRI data
    Wang, Lei
    Chitiboi, Teodora
    Meine, Hans
    Guenther, Matthias
    Hahn, Horst K.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (02) : 95 - 110
  • [36] Principles and methods for automatic and semi-automatic tissue segmentation in MRI data
    Lei Wang
    Teodora Chitiboi
    Hans Meine
    Matthias Günther
    Horst K. Hahn
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 95 - 110
  • [37] Semi-automatic calculation of prostate contour in ultrasound images
    Bilge, Hasan Sakir
    Verim, Volkan
    2007 IEEE 15TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS, VOLS 1-3, 2007, : 354 - 357
  • [38] Semi-Automatic segmentation of multiple mouse embryos in MR images
    Leila Baghdadi
    Mojdeh Zamyadi
    John G Sled
    Jürgen E Schneider
    Shuomo Bhattacharya
    R Mark Henkelman
    Jason P Lerch
    BMC Bioinformatics, 12
  • [39] Applicability of semi-automatic segmentation for volumetric analysis of brain lesions
    Heinonen, T.
    Dastidar, P.
    Eskola, H.
    Frey, H.
    Ryymin, P.
    Laasonen, E.
    Journal of Medical Engineering and Technology, 1998, 22 (04): : 173 - 178
  • [40] Semi-automatic lymph node segmentation in LN-MRI
    Unal, G.
    Slabaugh, G.
    Ess, A.
    Yezzi, A.
    Fang, T.
    Tyan, J.
    Requardtd, M.
    Kriegd, R.
    Seethainraju, R.
    Harisinghani, M.
    Weissleder, R.
    2006 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, ICIP 2006, PROCEEDINGS, 2006, : 77 - +