Design of magnesium alloys with controllable degradation for biomedical implants: From bulk to surface

被引:338
|
作者
Li, Xia [1 ]
Liu, Xiangmei [1 ]
Wu, Shuilin [1 ]
Yeung, K. W. K. [2 ]
Zheng, Yufeng [3 ,4 ]
Chu, Paul K. [5 ]
机构
[1] Hubei Univ, Hubei Collaborat Innovat Ctr Adv Organ Chem Mat, Key Lab Green Preparat & Applicat Funct Mat, Minist Educ,Hubei Key Lab Polymer Mat,Fac Mat Sci, Wuhan 430062, Peoples R China
[2] Univ Hong Kong, Li Ka Shing Fac Med, Div Spine Surg, Dept Orthopaed & Traumatol, Hong Kong, Hong Kong, Peoples R China
[3] Peking Univ, Coll Engn, State Key Lab Turbulence & Complex Syst, Beijing 100871, Peoples R China
[4] Peking Univ, Coll Engn, Dept Mat Sci & Engn, Beijing 100871, Peoples R China
[5] City Univ Hong Kong, Dept Phys & Mat Sci, Tat Chee Ave, Kowloon, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnesium alloys; Biodegradability; Implants; Corrosion; Surface modification; IN-VITRO DEGRADATION; HIGH-PURITY MG; ELECTROCHEMICAL CORROSION BEHAVIOR; IMMERSION ION-IMPLANTATION; ZN-Y ALLOYS; AMORPHOUS CALCIUM-PHOSPHATE; ALPHA-TRICALCIUM PHOSPHATE; SIMULATED BODY-FLUID; MECHANICAL-PROPERTIES; PURE MAGNESIUM;
D O I
10.1016/j.actbio.2016.09.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The combination of high strength, light weight, and natural biodegradability renders magnesium (Mg) based alloys promising in orthopedic implants and cardiovascular stents. Being metallic materials, Mg and Mg alloys made for scaffolds provide the necessary mechanical support for tissue healing and cell growth in the early stage, while natural degradation and reabsorption by surrounding tissues in the later stage make an unnecessarily follow-up removal surgery. However, uncontrolled degradation may collapse the scaffolds resulting in premature implant failure, and there has been much research in controlling the degradation rates of Mg alloys. This paper reviews recent progress in the design of novel Mg alloys, surface modification and corrosion mechanisms under different conditions, and describes the effects of the structure, composition, and surface conditions on the degradation behavior in vitro and in vivo. Statement of Significance Owing to their unique mechanical properties, biodegradability, biocompatibility, Mg based biomaterials are becoming the most promising substitutes for tissue regeneration for impaired bone, vascular and other tissues because these scaffolds can provide not only ideal space for the growth and differentiation of seeded cells but also enough strength before the formation of normal tissues. The most important is that these scaffolds can be fully degraded after tissue regeneration, which can satisfy the increasing demand for better biomedical devices and functional tissue engineering biomaterials in the world. However, the rapid degradation rate of these scaffolds restricts the wide application in clinic. This paper reviews recent progress on how to control the degrdation rate based on the relevant corrosion mechanisms through the design of porous structure, phase structure, grains, and amorphous structure as well as surface modification, which will be beneficial to the better understanding and functional design of Mg -based scaffolds for wide clinical applications in tissue reconstruction in near futures. (C) 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:2 / 30
页数:29
相关论文
共 50 条
  • [21] Magnesium alloys for temporary implants in osteosynthesis: In vivo studies of their degradation and interaction with bone
    Kraus, Tanja
    Fischerauer, Stefan F.
    Haenzi, Anja C.
    Uggowitzer, Peter J.
    Loeffler, Joerg F.
    Weinberg, Annelie M.
    ACTA BIOMATERIALIA, 2012, 8 (03) : 1230 - 1238
  • [22] Surface design of biodegradable magnesium alloys - A review
    Wu, Guosong
    Ibrahim, Jamesh Mohammed
    Chu, Paul K.
    SURFACE & COATINGS TECHNOLOGY, 2013, 233 : 2 - 12
  • [23] Prospects and strategies for magnesium alloys as biodegradable implants from crystalline to bulk metallic glasses and composites-A review
    Kiani, Faisal
    Wen, Cuie
    Li, Yuncang
    ACTA BIOMATERIALIA, 2020, 103 (103) : 1 - 23
  • [24] Surface design strategies of polymeric biomedical implants for antibacterial properties
    Meier, Elizabeth L.
    Jang, Yeongseon
    CURRENT OPINION IN BIOMEDICAL ENGINEERING, 2023, 26
  • [25] Composite Nanocoatings of Biomedical Magnesium Alloy Implants: Advantages, Mechanisms, and Design Strategies
    Li, Dan
    Dai, Danni
    Xiong, Gege
    Lan, Shuquan
    Zhang, Chao
    ADVANCED SCIENCE, 2023, 10 (18)
  • [26] A novel NIR-responsive coating for magnesium implants: Controllable degradation enhanced by air bomb
    Lv, You
    Liu, Xinying
    Zheng, Mingkun
    Shi, Xuemei
    Dong, Zehua
    Zhang, Xinxin
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2025, 230 : 151 - 164
  • [27] Research progress on surface protective coatings of biomedical degradable magnesium alloys
    Liu, Yun
    Zhang, Yuan
    Wang, Yan-Li
    Tian, Ya-Qiang
    Chen, Lian-Sheng
    JOURNAL OF ALLOYS AND COMPOUNDS, 2021, 885
  • [28] Research Progress on Surface Coating of Magnesium and its Alloys as Biomedical Materials
    Zhang, Wei
    RESOURCES AND SUSTAINABLE DEVELOPMENT, PTS 1-4, 2013, 734-737 : 2195 - 2199
  • [29] Tunable zinc corrosion rate by laser surface modification for implants with controllable degradation direction
    Chen, Peng
    Hu, Yazhou
    Liu, Shuo
    Wang, Hongshui
    Liu, Ning
    Liang, Chunyong
    JOURNAL OF MATERIALS SCIENCE, 2024, 59 (38) : 18263 - 18277
  • [30] Bioinspired Surface Design for Magnesium Alloys with Corrosion Resistance
    Wu, Feng
    Liu, Yixuan
    Xu, Jing
    Pan, Changjiang
    METALS, 2022, 12 (09)