On a PCA-based lung motion model

被引:81
|
作者
Li, Ruijiang [1 ,2 ]
Lewis, John H. [1 ,2 ]
Jia, Xun [1 ,2 ]
Zhao, Tianyu [3 ]
Liu, Weifeng [4 ]
Wuenschel, Sara [3 ]
Lamb, James [3 ]
Yang, Deshan [3 ]
Low, Daniel A. [3 ]
Jiang, Steve B. [1 ,2 ]
机构
[1] Univ Calif San Diego, Dept Radiat Oncol, La Jolla, CA 92037 USA
[2] Univ Calif San Diego, Ctr Adv Radiotherapy Technol, La Jolla, CA 92037 USA
[3] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
[4] Amazon Com Inc, Seattle, WA 98104 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 18期
关键词
3D TUMOR-LOCALIZATION; RESPIRATORY MOTION; CANCER RADIOTHERAPY; IMAGE REGISTRATION; RADIATION-THERAPY; 4D CT; PREDICTION;
D O I
10.1088/0031-9155/56/18/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiration-induced organ motion is one of the major uncertainties in lung cancer radiotherapy and is crucial to be able to accurately model the lung motion. Most work so far has focused on the study of the motion of a single point (usually the tumor center of mass), and much less work has been done to model the motion of the entire lung. Inspired by the work of Zhang et al (2007 Med. Phys. 34 4772-81), we believe that the spatiotemporal relationship of the entire lung motion can be accurately modeled based on principle component analysis (PCA) and then a sparse subset of the entire lung, such as an implanted marker, can be used to drive the motion of the entire lung (including the tumor). The goal of this work is twofold. First, we aim to understand the underlying reason why PCA is effective for modeling lung motion and find the optimal number of PCA coefficients for accurate lung motion modeling. We attempt to address the above important problems both in a theoretical framework and in the context of real clinical data. Second, we propose a new method to derive the entire lung motion using a single internal marker based on the PCA model. The main results of this work are as follows. We derived an important property which reveals the implicit regularization imposed by the PCA model. We then studied the model using two mathematical respiratory phantoms and 11 clinical 4DCT scans for eight lung cancer patients. For the mathematical phantoms with cosine and an even power (2n) of cosine motion, we proved that 2 and 2n PCA coefficients and eigenvectors will completely represent the lung motion, respectively. Moreover, for the cosine phantom, we derived the equivalence conditions for the PCA motion model and the physiological 5D lung motion model (Low et al 2005 Int. J. Radiat. Oncol. Biol. Phys. 63 921-9). For the clinical 4DCT data, we demonstrated the modeling power and generalization performance of the PCA model. The average 3D modeling error using PCA was within 1 mm (0.7 +/- 0.1 mm). When a single artificial internal marker was used to derive the lung motion, the average 3D error was found to be within 2 mm (1.8 +/- 0.3 mm) through comprehensive statistical analysis. The optimal number of PCA coefficients needs to be determined on a patient-by-patient basis and two PCA coefficients seem to be sufficient for accurate modeling of the lung motion for most patients. In conclusion, we have presented thorough theoretical analysis and clinical validation of the PCA lung motion model. The feasibility of deriving the entire lung motion using a single marker has also been demonstrated on clinical data using a simulation approach.
引用
收藏
页码:6009 / 6030
页数:22
相关论文
共 50 条
  • [1] PCA-Based Lung Motion Model
    Li, R.
    Lewis, J.
    Jia, X.
    Zhao, T.
    Lamb, J.
    Yang, D.
    Low, D.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [2] PCA-Based Robust Motion Data Recovery
    Li, Zhuorong
    Yu, Hongchuan
    Hai Dang Kieu
    Tung Long Vuong
    Zhang, Jian Jun
    [J]. IEEE ACCESS, 2020, 8 (08): : 76980 - 76990
  • [3] Efficient sparse PCA-based method for motion recognition
    Xiang, Jian
    Zhu, Hongli
    [J]. Journal of Information and Computational Science, 2014, 11 (17): : 6419 - 6426
  • [4] A Hierarchical PCA-based Anomaly Detection Model
    Tian, Biming
    Merrick, Kathryn
    Yu, Shui
    Hu, Jiankun
    [J]. 2013 INTERNATIONAL CONFERENCE ON COMPUTING, NETWORKING AND COMMUNICATIONS (ICNC), 2013,
  • [5] PCA-based walking engine using motion capture data
    Glardon, P
    Boulic, R
    Thalmann, D
    [J]. COMPUTER GRAPHICS INTERNATIONAL, PROCEEDINGS, 2004, : 292 - 298
  • [6] PCA-based safety evaluation model on geological environment
    Wang, Fengshan
    Rong, Quanbing
    Zhang, Hongjun
    [J]. JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2015, 15 (03) : 559 - 568
  • [7] PCA-based model selection and fitting for linear manifolds
    Imiya, A
    Ootani, H
    [J]. MACHINE LEARNING AND DATA MINING IN PATTERN RECOGNITION, 2001, 2123 : 278 - 292
  • [8] PCA-Based Algorithms to Find Synergies for Humanoid Robot Motion Behavior
    Tripathi, Gyanendra Nath
    Wagatsuma, Hiroaki
    [J]. INTERNATIONAL JOURNAL OF HUMANOID ROBOTICS, 2016, 13 (02)
  • [9] PCA-based Estimating Model of Multi-parameter Process
    Li Yan
    Shen Xiangli
    Chen Baolin
    Li Xiurong
    [J]. INTERNATIONAL CONFERENCE ON FUTURE COMPUTER SUPPORTED EDUCATION, 2012, 2 : 528 - 533
  • [10] Improving Human Motion Classification by Applying Bagging and Symmetry to PCA-Based Features
    Hachaj, Tomasz
    [J]. SYMMETRY-BASEL, 2019, 11 (10):