Application of Special Shaped Column Composed of Concrete-Filled Steel Tubes

被引:7
|
作者
Chen, Zhihua [1 ]
Zhou, Ting [1 ]
Wang, Xiaodun [1 ]
机构
[1] Tianjin Univ, Dept Civil Engn, Tianjin 300072, Peoples R China
来源
ADVANCES IN STRUCTURES, PTS 1-5 | 2011年 / 163-167卷
关键词
Special-Shaped Column Composed Of Concrete-Filled Steel Tubes (SCFT); Concrete Filled Steel Tubular (CFT); Vertical Stiffener Joint; Design Of Residential Building;
D O I
10.4028/www.scientific.net/AMR.163-167.196
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Special-shaped column composed of concrete-filled steel tubes (SCFT) structure, a new type structure, is adopted to a residential building. This paper represents the design and analysis of this structure. 3D model of the structure is built by finite element procedure software and vibration property, static and seismic performance of the building are also analyzed to check the safety of the structure. At last, the vertical stiffener joint of SCFT structure is proposed and calculated. The application of SCFT for residential building represents that the SCFT is suitable for real constructions.
引用
收藏
页码:196 / 199
页数:4
相关论文
共 50 条
  • [31] PERFORMANCE STUDY OF CONCRETE-FILLED STEEL TUBES
    Chair, A.
    Djebbar, A.
    Djebbar, N.
    INTERNATIONAL CONGRESS ON MATERIALS & STRUCTURAL STABILITY, 2014, 11
  • [32] Creep modeling for concrete-filled steel tubes
    Naguib, W
    Mirmiran, A
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (11) : 1327 - 1344
  • [33] Axially loaded concrete-filled steel tubes
    Schneider, SP
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (10): : 1125 - 1138
  • [34] Experimental investigation of special-shaped concrete-filled steel tubular column to steel beam connections under cyclic loading
    Liu, Jingchen
    Yang, Yuanlong
    Liu, Jiepeng
    Zhou, Xuhong
    ENGINEERING STRUCTURES, 2017, 151 : 68 - 84
  • [35] Experimental research on X-shaped joints of concrete-filled steel tube column
    College of Engineering, Tianjin University, Tianjin 300072, China
    不详
    不详
    Jianzhu Jiegou Xuebao, 2008, SUPPL. (62-67): : 62 - 67
  • [36] Behavior of Concrete-Filled U-Shaped Steel Beam to CFSST Column Connections
    Lin, Yan
    Zhao, Zhijie
    Gao, Xuhui
    Wang, Zhen
    Qu, Shuang
    BUILDINGS, 2023, 13 (02)
  • [37] Study on Bearing Capacity of the Connection between Concrete-Filled Twin Steel Tubes Column and Steel Beam
    Zhang Yufen
    Wang Qiang
    PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, 2016, 43 : 1096 - 1102
  • [38] MECHANICAL PRORERTIES OF EXPOSED COLUMN BASE CONNECTIONS FOR L- SHAPED COLUMNS FABRICATED USING CONCRETE-FILLED STEEL TUBES
    Su, Jing
    Zhou, Ting
    Chen, Zhi-Hua
    Wang, Xiao-Dun
    ADVANCED STEEL CONSTRUCTION, 2021, 17 (04): : 356 - 365
  • [39] Application and development of concrete-filled steel tubes (CFST) in high rise buildings
    Zhong, Shan-tong
    Zhang, Sumei
    Advances in Structural Engineering, 1999, 2 (02): : 149 - 159
  • [40] Numerical analysis of concrete-filled circular steel tubes
    Deng, Yaohua
    Norton, Terri R.
    Tuan, Christopher Y.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2013, 166 (01) : 3 - 14