Photon and photon-neutron experimental dosimetry in Grid therapy with 18 MV photon beams

被引:3
|
作者
Tajiki, Sareh [1 ]
Gholami, Somayeh [1 ]
Esfahani, Mahbod [1 ]
Rastjoo, Ali [1 ]
Hakimi, Amir [2 ]
Beheshti, Amir K. [3 ]
Meigooni, Ali [4 ]
机构
[1] Univ Tehran Med Sci, Inst Canc, Dept Radiat Oncol, Tehran, Iran
[2] Amirkabir Univ Technol, Dept Energy Engn & Phys, Hlth Phys & Dosimetry Res Lab, Tehran, Iran
[3] Univ Isfahan, Dept Nucl Engn, Esfahan, Iran
[4] Comprehens Canc Ctr Nevada, Las Vegas, NV USA
关键词
grid therapy; neutron contamination; Polycarbonate Film; Spatially fractionated radiation therapy; TLD; BLOCK; ADVANTAGE; RADIATION; SIZE;
D O I
10.1017/S1460396920000655
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Propose: Spatially fractionated Grid radiation therapy (SFGRT) in an effective technique for bulky and radio-sensitive tumours. SFGRT using a constructed block has been used to evaluate the photon and photo-neutron (PN) dose measurement in 18-MV photon beam energy. Methods and materials: A mounted Grid block on to a Varian Clinac 2100c linear accelerator was used to perform photon dosimetry. The percentage depth dose, in-plane and cross-plane beam profile and output factor was measured by ionization chamber in water. The PN contamination was measured after photon dosimetry using the combination of thermoluminescence dosimetry types 600 and 700, and Polycarbonate Film dosimeters on the surface and in the maximum depth dose (d(max)) of solid water (TM) slabs. Results: The valley-to-peak ration for 6 and 18 MV photon beams obtained from the beam profiles was similar to 35 and 72%, respectively. Fast and thermal PN equivalent dose decreased in the Grid field compared to an open field (without Grid). Conclusion: The Grid therapy dosimetry compared to the conventional radiotherapy (without the grid) the production of fast and thermal neutrons were reduced. Using of a Grid block in high-energy photon beams for a long period of the treatment continuously might be a new source of contamination due to the interaction of photon beam resulting the activation of the Grid block
引用
收藏
页码:466 / 472
页数:7
相关论文
共 50 条
  • [1] CIRCEG, A PORTABLE DEVICE FOR PHOTON-NEUTRON DOSIMETRY
    MARCHETTO, A
    LEROUX, JB
    HERBAUT, Y
    LATU, M
    TINELLI, P
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 253 - 256
  • [2] PHOTON-NEUTRON THERAPY FOR RECURRENT INOPERABLE RECTOSIGMOID TUMORS
    ENGENHART, R
    KIMMIG, B
    MARINGREZ, M
    HOVER, KH
    FLENTJE, M
    VANKAICK, G
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 1988, 26 (09): : 552 - 552
  • [3] Neutron dose measurement in Intensity Modulated Radiotherapy of 18 MV photon beams
    Chern, SS
    Selvaraj, RN
    Sheetz, M
    Wu, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1267 - 1268
  • [4] Electron contamination in 8 and 18 MV photon beams
    Zhu, TC
    Palta, JR
    MEDICAL PHYSICS, 1998, 25 (01) : 12 - 19
  • [5] LYOLUMINESCENCE DOSIMETRY IN PHOTON AND FAST-NEUTRON BEAMS
    PUITE, KJ
    CREBOLDER, DLJM
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (06): : 1136 - 1145
  • [6] MIXED PHOTON-NEUTRON FIELD MEASUREMENTS.
    Nath, Ravinder
    Price, K.W.
    Holeman, G.R.
    National Bureau of Standards, Special Publication, 1979, (554 Proc of a Conf on Neutrons from Electron Med Accel): : 87 - 97
  • [7] Neutron dose in and out of 18 MV photon fields
    Ezzati, A. O.
    Studenski, M. T.
    APPLIED RADIATION AND ISOTOPES, 2017, 122 : 186 - 192
  • [8] A Neutron Measurement Comparison of Varian and Elekta 10&18 MV Photon Beams
    Chen, K.
    Klein, E.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [9] Dosimetry of photon pencil beams
    Paskalev, K
    Seuntjens, J
    Podgorsak, E
    MEDICAL PHYSICS, 2002, 29 (06) : 1372 - 1372
  • [10] Combined photon-neutron radiography for nondestructive analysis of materials
    Hartman, Jessica
    Barzilov, Alexander
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 2307 - 2312