Baseline Wandering Removal from ECG Signal by Wandering Path Finding Algorithm

被引:0
|
作者
Rahman, Md. Asadur [1 ]
Milu, Md. Mahmudul Haque [1 ]
Anjum, Anika [1 ]
Khanam, Farzana [1 ]
Ahmad, Mohiuddin [2 ]
机构
[1] Khulna Univ Engn & Technol, Dept Biomed Engn, Khulna, Bangladesh
[2] Khulna Univ Engn & Technol, Dept Elect & Elect Engn, Khulna, Bangladesh
关键词
Electrocardiogram (ECG); baseline wandering; baseline wandering path finding (BWPF) algorithm; polynomial fitting;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work investigates to remove highly wandered path from ECG signal. In normal condition, ECG signal contains a very little amount of baseline wandering which can easily be removed by high pass filtering. On the other hand, acquired ECG signal during walking, running, push-up or pull-up the body contain different shapes of baseline wandering which cannot be possible to remove by conventional filtering concept. To meet the challenge, in this paper we have proposed a baseline wandering removal technique based on baseline wandering path finding (BWPF) algorithm. This BWPF algorithm works by piecewise polynomial fitting. In this paper, the impact of this algorithm on wandered ECG signal is discussed elaborately with graphical interpretations. In addition, it is also shown that why this algorithm works better than the conventional polynomial baseline wandering removing technique.
引用
收藏
页数:5
相关论文
共 50 条
  • [11] Total removal of baseline drift from ECG signal
    Chouhan, V. S.
    Mehta, S. S.
    [J]. ICCTA 2007: INTERNATIONAL CONFERENCE ON COMPUTING: THEORY AND APPLICATIONS, PROCEEDINGS, 2007, : 512 - +
  • [12] Multiadaptive Bionic Wavelet Transform: Application to ECG Denoising and Baseline Wandering Reduction
    Omid Sayadi
    Mohammad B. Shamsollahi
    [J]. EURASIP Journal on Advances in Signal Processing, 2007
  • [13] Multiadaptive bionic wavelet transform: Application to ECG denoising and baseline wandering reduction
    Sayadi, Omid
    Shamsollahi, Mohammad B.
    [J]. EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2007, 2007 (1)
  • [14] Estimation of wandering ECG signal baseline using detection of characteristic points in PQRST complex for avoiding distortions in complex morphology
    ͆ledzik, Joanna
    Stelengowska, Miroslawa
    [J]. Advances in Intelligent and Soft Computing, 2011, 95 (04): : 587 - 596
  • [15] A Robust Sparse Signal Decomposition Framework for Baseline Wander Removal from ECG Signal
    Satija, Udit
    Ramkumar, Barathram
    Manikandan, M. Sabarimalai
    [J]. PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 2470 - 2473
  • [16] A new algorithm for removal baseline wander in ECG signal based on empirical mode decomposition
    Zhao Zhidong
    Sun Shuqiang
    [J]. ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 1559 - 1562
  • [17] WANDERING FROM PATH + IRISH PHILOSOPHY, ERIUGENA,JOHN,SCOTTUS
    MORAN, D
    [J]. CRANE BAG, 1978, 2 (1-2): : 96 - 102
  • [18] De-noising and baseline wandering removal of electrocardiogram using double density discrete wavelet
    Kumari, R. Shantha Selva
    Sadasivam, V.
    [J]. INTERNATIONAL JOURNAL OF WAVELETS MULTIRESOLUTION AND INFORMATION PROCESSING, 2007, 5 (03) : 399 - 415
  • [19] Study and Evaluation of Denoising and Baseline wandering of Computerized wrist pulse signal using Virtual Instrument
    Chopra, Manu
    Kaur, Ramandeep
    Garg, Nidhi
    [J]. 2015 1ST INTERNATIONAL CONFERENCE ON NEXT GENERATION COMPUTING TECHNOLOGIES (NGCT), 2015, : 576 - 579
  • [20] Trend Removal of ECG Signal with LMS Algorithm
    Bozok, Buse
    Arica, Sami
    [J]. 2019 MEDICAL TECHNOLOGIES CONGRESS (TIPTEKNO), 2019, : 318 - 321