Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment

被引:371
|
作者
Kulcsar, Z. [1 ]
Houdart, E. [2 ]
Bonafe, A. [4 ]
Parker, G. [5 ]
Millar, J. [6 ]
Goddard, A. J. P. [7 ]
Renowden, S. [8 ]
Gal, G. [9 ]
Turowski, B. [10 ]
Mitchell, K. [11 ]
Gray, F. [3 ]
Rodriguez, M. [12 ]
van den Berg, R. [13 ]
Gruber, A. [14 ]
Desal, H. [15 ]
Wanke, I. [1 ]
Ruefenacht, D. A. [1 ]
机构
[1] Swiss Neuro Inst Hirslanden, Dept Neuroradiol, Clin Hirslanden, Zurich, Switzerland
[2] Hop Lariboisiere, Dept Diagnost & Intervent Neuroradiol, F-75475 Paris, France
[3] Hop Lariboisiere, Dept Pathol, F-75475 Paris, France
[4] Gui de Chauliac Hosp, Univ Hosp Ctr, Dept Neuroradiol, Montpellier, France
[5] Royal Prince Alfred Hosp, Dept Neuroradiol, Sydney, NSW, Australia
[6] Southampton Gen Hosp, Dept Neuroradiol, Wessex Neurol Ctr, Southampton, England
[7] Leeds Gen Infirm, Dept Neuroradiol, Leeds, W Yorkshire, England
[8] Frenchay Hosp Bristol, Dept Neuroradiol, Bristol, Avon, England
[9] Odense Univ Hosp, Dept Neuroradiol, DK-5000 Odense, Denmark
[10] Univ Dusseldorf, Inst Radiol Neuroradiol, Dusseldorf, Germany
[11] Royal Brisbane & Womens Hosp, Dept Med Imaging, Herston, Qld, Australia
[12] Sydney SW Area Hlth Serv, Dept Forens Med, Sydney, NSW, Australia
[13] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[14] Med Univ Vienna, Vienna Gen Hosp, Dept Neurosurg, Vienna, Austria
[15] CHU Nantes, Univ Hosp, Laennec Hosp, Dept Neuroradiol, Nantes, France
关键词
PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; ENDOVASCULAR TREATMENT; MURAL THROMBUS; ASPECT RATIO; RECONSTRUCTION; EXPERIENCE; EVOLUTION; ARTERY;
D O I
10.3174/ajnr.A2370
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: FD technology enables reconstructive repair of otherwise difficult-to-treat intracranial aneurysms. These stentlike devices may induce progressive aneurysm thrombosis without additional implants and may initiate complete reverse vessel remodeling. The associated vascular biologic processes are as yet only partially understood. MATERIALS AND METHODS: From 12 different centers, 13 cases of delayed postprocedural aneurysm rupture were recorded and analyzed. Symptom, aneurysm location and morphology, and the time elapsed from treatment until rupture were analyzed. RESULTS: There were 10 internal carotid and 3 basilar artery aneurysms. Mean aneurysm diameter was 22 6 mm. Eleven patients were symptomatic before treatment. A single FD was used for all saccular aneurysms, while fusiform lesions were treated by using multiple devices. A supplementary loose coiling of the aneurysm was performed in 1 patient only. Ten patients developed early aneurysm rupture after FD treatment (mean, 16 days; range, 2-48 days); in 3 patients, rupture occurred 3-5 months after treatment. In all cases, most of the aneurysm cavity was thrombosed before rupture. The biologic mechanisms predisposing to rupture under these conditions are reviewed and discussed CONCLUSIONS: FDs alone may modify hemodynamics in ways that induce extensive aneurysm thrombosis. Under specific conditions, however, instead of reverse remodeling and cicatrization, aggressive thrombus-associated autolysis of the aneurysm wall may result in delayed rupture.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 50 条
  • [21] Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis
    Zsolt Kulcsár
    Luca Augsburger
    Philippe Reymond
    Vitor M. Pereira
    Sven Hirsch
    Ajit S. Mallik
    John Millar
    Stephan G. Wetzel
    Isabel Wanke
    Daniel A. Rüfenacht
    [J]. Acta Neurochirurgica, 2012, 154 : 1827 - 1834
  • [22] CFD to Quantify Idealized Intra-Aneurysmal Blood Flow in Response to Regular and Flow Diverter Stent Treatment
    Sanches, Augusto Fava
    Shit, Suprosanna
    Oezpeynirci, Yigit
    Liebig, Thomas
    [J]. FLUIDS, 2022, 7 (08)
  • [23] Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics:: flow quantification in elastic sidewall aneurysm models
    Baráth, K
    Cassot, F
    Fasel, JHD
    Ohta, M
    Rüfenacht, DA
    [J]. NEUROLOGICAL RESEARCH, 2005, 27 : S120 - S128
  • [24] Intra-aneurysmal hemodynamics: evaluation of pCONus and pCANvas bifurcation aneurysm devices using DSA optical flow imaging
    Perez, Marta Aguilar
    Henkes, Hans
    Bouillot, Pierre
    Brina, Olivier
    Slater, Lee-Anne
    Pereira, Vitor Mendes
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (11) : 1197 - 1201
  • [25] Intra-Aneurysmal Rupture of an Atheroma during the Clipping of Large Atherosclerotic Aneurysm of the Middle Cerebral Artery: A Case Report with Video Demonstration
    Chung, Yeongu
    Park, Wonhyoung
    Park, Jung Cheol
    Chung, Jaewoo
    Ahn, Jae Sung
    [J]. JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2019, 80 (05) : 391 - 395
  • [26] Evaluation of Intra-Aneurysmal Residual Blood Flow with the iMSDE T1-Black Blood Imaging after Flow Diverter Treatment
    Suzuki, Yume
    Toma, Naoki
    Inoue, Katsuhiro
    Ichikawa, Tomonori
    Nishikawa, Hirofumi
    Miura, Yoichi
    Fujimoto, Masashi
    Yasuda, Ryuta
    Maeda, Masayuki
    Suzuki, Hidenori
    [J]. JOURNAL OF NEUROENDOVASCULAR THERAPY, 2023, 17 (08) : 159 - 166
  • [27] Intra-aneurysmal flow rates are reduced by two flow diverters: an experiment using tomographic particle image velocimetry in an aneurysm model
    Dennis, Kendall D.
    Rossman, Timothy L.
    Kallmes, David F.
    Dragomir-Daescu, Dan
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (12) : 937 - 942
  • [28] Intimal Hyperplasia After Aneurysm Treatment by Flow Diversion
    Sindeev, Sergey
    Prothmann, Sascha
    Frolov, Sergey
    Zimmer, Claus
    Liepsch, Dieter
    Berg, Philipp
    Kirschke, Jan Stefan
    Friedrich, Benjamin
    [J]. WORLD NEUROSURGERY, 2019, 122 : E577 - E583
  • [29] Evaluation of intra-aneurysmal blood flow by digital subtraction angiography: Blood flow change after coil embolization
    Asakura, F
    Tenjin, H
    Sugawa, N
    Kimura, S
    Oki, F
    Yonekawa, Y
    [J]. SURGICAL NEUROLOGY, 2003, 59 (04): : 310 - 319
  • [30] A Case of Early Rupture Following Flow-Diversion with Quantification of Hemodynamics and Aneurysmal Wall Stress using Additive Manufacturing and Particle Tracking Velocimetry
    Cook, Melissa
    Meja-Alvarez, Ricardo
    Mehta, Nikhil
    Chason, David
    Willis, Adam
    [J]. NEUROLOGY, 2020, 94 (15)