Optical quality of the eye degraded by time-varying wavefront aberrations with tear film dynamics

被引:15
|
作者
Hirohara, Yoko
Mihashi, Toshifumi
Koh, Shizuka
Ninomiya, Sayuri
Maeda, Naoyuki
Fujikado, Takashi
机构
[1] Osaka Univ, Grad Sch Med, Dept Appl Visual Sci, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Ophthalmol, Osaka, Japan
[3] Topcon Corp, Res Inst, Tokyo, Japan
关键词
aberration; retinal image; Shack-Hartmann aberrometer; Strehl ratio; tear film;
D O I
10.1007/s10384-007-0440-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Wavefront aberrations (WFAs) of the eye vary with time because of the tear film dynamics. We investigated, using a simulation method, the variation of optical quality with time-varying wavefront measurements of 13 eyes with different refractions. Methods: WFAs of 13 normal eyes of 13 subjects were measured every second for 10s. First, we simulated WFAs with conventional corneal laser refractive surgery by subtracting the second-order aberrations of the least aberrated measurement from measured consecutive WFAs. Second, we simulated customized refractive surgery by subtracting the second- to sixth-order aberrations of the least aberrated measurement from measured consecutive WFAs. We calculated Strehl ratios and retinal images from these corrected consecutive WFAs. Results: In one eye, the root mean square (RMS) values of WFAs with a second-order correction were sometimes smaller than those of WFAs with a second- to sixth-order correction, when these were compared at the same time point after a blink. However, in the other 12 eyes, the RMS values with second- to sixth-order corrections were smaller than those with only a second-order correction. In eight eyes, the Strehl ratios with second- to sixth-order corrections were larger than those with second-order corrections. In the remaining five eyes, Strehl ratios with second- to sixth-order corrections were sometimes smaller than those with second-order corrections. Conclusions: In a simulation, the correction of time-invariant higher order aberrations usually reduced RMS values, but it did not always result in higher Strehl ratios than those obtained with only second-order corrections.
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [1] Optical Quality of the Eye Degraded by Time-Varying Wavefront Aberrations with Tear Film Dynamics
    Yoko Hirohara
    Toshifumi Mihashi
    Shizuka Koh
    Sayuri Ninomiya
    Naoyuki Maeda
    Takashi Fujikado
    Japanese Journal of Ophthalmology, 2007, 51 : 258 - 264
  • [2] The Tear Film and the Optical Quality of the Eye
    Montes-Mico, Robert
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Madrid-Costa, David
    OCULAR SURFACE, 2010, 8 (04): : 185 - 192
  • [3] Predictive wavefront sensorless adaptive optics for time-varying aberrations
    Piscaer, Pieter
    Soloviev, Oleg
    Verhaegen, Michel
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2019, 36 (11) : 1810 - 1819
  • [4] Wavefront sensing and the dynamics of tear film
    Koh, Shizuka
    Maeda, Naoyuki
    CORNEA, 2007, 26 (09) : S41 - S45
  • [5] Role of the tear film in the optical quality of the human eye
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (09): : 1631 - 1635
  • [6] Measuring the effect of the tear film on the optical quality of the eye
    Dubra, A
    Dainty, JC
    Paterson, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U469 - U469
  • [7] Assessment of Tear Film Optical Quality Dynamics
    Yu, A-Yong
    Lu, Ting
    Pan, An-Peng
    Lin, Duo-Ru
    Xu, Chen-Chen
    Huang, Jin-Hai
    Bao, Fang-Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (08) : 3821 - 3827
  • [8] Changes in aberrations and retinal image quality due to tear film dynamics
    Li, Kaccie Y.
    Yoon, Geunyoung
    OPTICS EXPRESS, 2006, 14 (25): : 12552 - 12559
  • [9] Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease
    An-Peng Pan
    Yunjing Ma
    Ruilin Hu
    Xuejiao Cao
    Yifen Wu
    Kaijing Zhou
    Ruixue Tu
    Xu Shao
    Shihao Chen
    A-Yong Yu
    Eye and Vision, 10
  • [10] Simultaneous real-time analysis of tear film optical quality dynamics and functional visual acuity in dry eye disease
    Pan, An-Peng
    Ma, Yunjing
    Hu, Ruilin
    Cao, Xuejiao
    Wu, Yifen
    Zhou, Kaijing
    Tu, Ruixue
    Shao, Xu
    Chen, Shihao
    Yu, A-Yong
    EYE AND VISION, 2023, 10 (01)