Image Quality Comparison between Digital Breast Tomosynthesis Images and 2D Mammographic Images Using the CDMAM Test Object

被引:0
|
作者
Tsalafoutas, Ioannis A. [1 ]
Epistatou, Angeliki C. [2 ]
Delibasis, Konstantinos K. [2 ]
机构
[1] Hamad Med Corp, Radiat Safety Sect, Occupat Hlth & Safety Dept, POB 3050, Doha, Qatar
[2] Univ Thessaly, Dept Comp Sci & Biomed Informat, Lamia 35131, Greece
关键词
digital mammography; digital breast tomosynthesis (DBT); image quality; CDMAM; SYNTHESIZED MAMMOGRAPHY; DIAGNOSTIC PERFORMANCE; CANCER-DETECTION; CONVERSION;
D O I
10.3390/jimaging8080223
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
PurposeTo evaluate the image quality (IQ) of synthesized two-dimensional (s2D) and tomographic layer (TL) mammographic images in comparison to the 2D digital mammographic images produced with a new digital breast tomosynthesis (DBT) system. Methods: The CDMAM test object was used for IQ evaluation of actual 2D images, s2D and TL images, acquired using all available acquisition modes. Evaluation was performed automatically using the commercial software that accompanied CDMAM. Results: The IQ scores of the TLs with the in-focus CDMAM were comparable, although usually inferior to those of 2D images acquired with the same acquisition mode, and better than the respective s2D images. The IQ results of TLs satisfied the EUREF limits applicable to 2D images, whereas for s2D images this was not the case. The use of high-dose mode (H-mode), instead of normal-dose mode (N-mode), increased the image quality of both TL and s2D images, especially when the standard mode (ST) was used. Although the high-resolution (HR) mode produced TL images of similar or better image quality compared to ST mode, HR s2D images were clearly inferior to ST s2D images. Conclusions: s2D images present inferior image quality compared to 2D and TL images. The HR mode produces TL images and s2D images with half the pixel size and requires a 25% increase in average glandular dose (AGD). Despite that, IQ evaluation results with CDMAM are in favor of HR resolution mode only for TL images and mainly for smaller-sized details.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Breast Cancer Conspicuity on Simultaneously Acquired Digital Mammographic Images versus Digital Breast Tomosynthesis Images
    Korhonen, Katrina E.
    Conant, Emily E.
    Cohen, Eric A.
    Synnestvedt, Marie
    McDonald, Elizabeth S.
    Weinstein, Susan P.
    [J]. RADIOLOGY, 2019, 292 (01) : 69 - 76
  • [2] Comparison of digital breast tomosynthesis and 2D digital mammography using a hybrid performance test
    Cockmartin, Lesley
    Marshall, Nicholas W.
    Van Ongeval, Chantal
    Aerts, Gwen
    Stalmans, Davina
    Zanca, Federica
    Shaheen, Eman
    De Keyzer, Frederik
    Dance, David R.
    Young, Kenneth C.
    Bosmans, Hilde
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10): : 3939 - 3958
  • [3] Two-View Digital Breast Tomosynthesis Screening with Synthetically Reconstructed Projection Images: Comparison with Digital Breast Tomosynthesis with Full-Field Digital Mammographic Images
    Skaane, Per
    Bandos, Andriy I.
    Eben, Ellen B.
    Jebsen, Ingvild N.
    Krager, Mona
    Haakenaasen, Unni
    Ekseth, Ulrika
    Izadi, Mina
    Hofvind, Solveig
    Gullien, Randi
    [J]. RADIOLOGY, 2014, 271 (03) : 655 - 663
  • [4] Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems
    Young, Kenneth C.
    Cook, James J. H.
    Oduko, Jennifer M.
    Bosmans, Hilde
    [J]. MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [5] Comparison of synthetic 2D images with planar and tomosynthesis imaging of the breast using a virtual clinical trial
    Mackenzie, Alistair
    Kaur, Sukhmanjit
    Elangovan, Premkumar
    Dance, David R.
    Young, Kenneth C.
    [J]. MEDICAL IMAGING 2018: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2018, 10577
  • [6] Synthesising two-dimensional mammographic images using compressed sensing-reconstructed digital breast tomosynthesis images
    Han, Seohee
    Yang, Hyesun
    Xu, Wenting
    Seo, Changwoo
    Cho, Hyosung
    Cha, Bo Kyung
    [J]. JOURNAL OF INSTRUMENTATION, 2024, 19 (08):
  • [7] A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D images
    Sara Vecchio
    Achille Albanese
    Paolo Vignoli
    Angelo Taibi
    [J]. European Radiology, 2011, 21 : 1207 - 1213
  • [8] A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D images
    Vecchio, Sara
    Albanese, Achille
    Vignoli, Paolo
    Taibi, Angelo
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (06) : 1207 - 1213
  • [9] Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems
    Young, Kenneth C.
    Alsager, Abdulaziz
    Oduko, Jennifer M.
    Bosmans, Hilde
    Verbrugge, Beatrijs
    Geertse, Tanya
    van Engene, Ruben
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [10] Computerized detection of mammographic masses in digital breast tomosynthesis images using radial gradient index filtering
    Reiser, I
    Nishikawa, RM
    Giger, ML
    Rafferty, EA
    Kopans, DB
    Moore, R
    Wu, T
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1352 - 1352