A low power and small area digital self-calibration technique for pipeline ADC

被引:11
|
作者
Lv, Jian [1 ]
Que, Longcheng [1 ]
Wei, Linhai [1 ]
Meng, Zhijun [1 ]
Zhou, Yun [1 ]
机构
[1] Univ Elect Sci & Technol China, State Key Lab Elect Thin Films & Integrated Devic, 4,Sect 2,North Jianshe Rd, Chengdu 610054, Sichuan, Peoples R China
关键词
Analog-to-digital conversion; Analog-to-digital converter (ADC) calibration; Pipeline processing; Capacitor mismatch; Discontinuity-error and gain-error correction;
D O I
10.1016/j.aeue.2017.08.025
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A digital self-calibration implementation with discontinuity-error and gain-error corrections for a pipeline analog-to-digital converter (ADC) is presented. In the proposed calibration method, the error owing to each reference unit capacitor of the multiplying D/A converter is measured separately using a calibration capacitor and an enhanced resolution back-end pipeline ADC acting as an error quantizer. The offset and finite open loop DC-gain of the operational amplifier and capacitor mismatches, the reference voltage mismatch can all be calibrated. The calibration can be achieved by that only used addition and subtraction. Hence, it needs low power and area consuming. A prototype ADC with the proposed calibration was fabricated on a 0.5 mu m double-poly triple-metal CMOS process. The power consumption and area of the calibration circuit are only 10.1 mW and 1.05 mm(2), respectively. At a sampling rate of 30 MS/s, the calibration improves the DNL and INL from 2.59 LSB and 14.98 LSB to 0.72 LSB and 1.82 LSB, respectively. For a 1.25 MHz sinusoidal signal, the calibration improves the signal-to-noise-distortion ratio and spurious free dynamic range from 43.1 dB and 52.1 dB to 75.51 dB and 83.61 dB, respectively. The 12.25 effective number of bits at 30 MS/s ADC consumes a total power of 136 mW. (C) 2017 Elsevier GmbH. All rights reserved.
引用
收藏
页码:52 / 57
页数:6
相关论文
共 50 条
  • [31] Low Power SAR ADC Design with Digital Background Calibration Algorithm
    Li, Shouping
    Chen, Jianjun
    Liang, Bin
    Guo, Yang
    SYMMETRY-BASEL, 2020, 12 (11): : 1 - 11
  • [32] Built-in Self-Calibration of On-chip DAC and ADC
    Jiang, Wei
    Agrawal, Vishwani D.
    2008 IEEE INTERNATIONAL TEST CONFERENCE, VOLS 1 AND 2, PROCEEDINGS, 2008, : 834 - 843
  • [33] Precise fabrication of large-area microstructures by digital oblique scanning lithography strategy and stage self-calibration technique
    Huang, Shengzhou
    Li, Mujun
    Wang, Lei
    Su, Yongsheng
    Liang, Yi
    APPLIED PHYSICS EXPRESS, 2019, 12 (09)
  • [34] Digital self-calibration method for MEMS sensors
    Colinet, E
    Juillard, J
    Nicu, L
    Bergaud, C
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (04) : 1438 - 1443
  • [35] SELF-CALIBRATION EXTENDS USEFULNESS OF DIGITAL MULTIMETERS
    FRYE, J
    CONTROL ENGINEERING, 1980, 27 (02) : 128 - &
  • [36] Area-Power-Efficient 11-Bit Hybrid Dual-Vdd ADC with Self-Calibration for Neural Sensing Application
    Chen, Jr-Ming
    Huang, Po-Tsang
    Wu, Shang-Lin
    Hwang, Wei
    Chuang, Ching-Te
    2016 29TH IEEE INTERNATIONAL SYSTEM-ON-CHIP CONFERENCE (SOCC), 2016, : 18 - 23
  • [37] New linear camera self-calibration technique
    Li, Hua
    Wu, Fu-Chao
    Hu, Zhan-Yi
    Jisuanji Xuebao/Chinese Journal of Computers, 2000, 23 (11): : 1121 - 1129
  • [38] A self-calibration technique for a Thomson scattering system
    Smith, ORP
    Gowers, C
    Nielsen, P
    Salzmann, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 725 - 727
  • [39] Self-calibration technique for transmitted wavefront measurements
    Bergner, BC
    Davies, A
    OPTICAL MANUFACUTRING AND TESTING V, 2003, 5180 : 236 - 243
  • [40] LRR - A self-calibration technique for the calibration of vector network analyzers
    Rolfes, I
    Schiek, B
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) : 316 - 319