Measuring signal-to-noise ratio in partially parallel imaging MRI

被引:109
|
作者
Goerner, Frank L. [1 ]
Clarke, Geoffrey D. [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiol, San Antonio, TX 78229 USA
关键词
MRI; partially parallel imaging; mSENSE; GRAPPA; SNR; IMAGES; COIL; RECONSTRUCTIONS; ARRAYS; GRAPPA;
D O I
10.1118/1.3618730
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess five different methods of signal-to-noise ratio (SNR) measurement for partially parallel imaging (PPI) acquisitions. Methods: Measurements were performed on a spherical phantom and three volunteers using a multichannel head coil a clinical 3T MRI system to produce echo planar, fast spin echo, gradient echo, and balanced steady state free precession image acquisitions. Two different PPI acquisitions, generalized autocalibrating partially parallel acquisition algorithm and modified sensitivity encoding with acceleration factors (R) of 2-4, were evaluated and compared to nonaccelerated acquisitions. Five standard SNR measurement techniques were investigated and Bland-Altman analysis was used to determine agreement between the various SNR methods. The estimated g-factor values, associated with each method of SNR calculation and PPI reconstruction method, were also subjected to assessments that considered the effects on SNR due to reconstruction method, phase encoding direction, and R-value. Results: Only two SNR measurement methods produced g-factors in agreement with theoretical expectations (g >= 1). Bland-Altman tests demonstrated that these two methods also gave the most similar results relative to the other three measurements. R-value was the only factor of the three we considered that showed significant influence on SNR changes. Conclusions: Non-signal methods used in SNR evaluation do not produce results consistent with expectations in the investigated PPI protocols. Two of the methods studied provided the most accurate and useful results. Of these two methods, it is recommended, when evaluating PPI protocols, the image subtraction method be used for SNR calculations due to its relative accuracy and ease of implementation. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3618730]
引用
收藏
页码:5049 / 5057
页数:9
相关论文
共 50 条
  • [1] Signal-to-noise ratio in MRI
    Redpath, TW
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (847): : 704 - 707
  • [2] Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging
    Sodickson, DK
    Griswold, MA
    Jakob, PM
    Edelman, RR
    Manning, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (05) : 1009 - 1022
  • [3] Measuring the signal-to-noise ratio in magnetic resonance imaging: a caveat
    Erdogmus, D
    Larsson, EG
    Yan, R
    Principe, JC
    Fitzsimmons, JR
    [J]. SIGNAL PROCESSING, 2004, 84 (06) : 1035 - 1040
  • [4] Measuring the signal-to-noise ratio of a neuron
    Czanner, Gabriela
    Sarma, Sridevi V.
    Ba, Demba
    Eden, Uri T.
    Wu, Wei
    Eskandar, Emad
    Lim, Hubert H.
    Temereanca, Simona
    Suzuki, Wendy A.
    Brown, Emery N.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2015, 112 (23) : 7141 - 7146
  • [5] Measuring multielectron beam imaging fidelity with a signal-to-noise ratio analysis
    Mukhtar, Maseeh
    Bunday, Benjamin D.
    Quoi, Kathy
    Malloy, Matt
    Thiel, Brad
    [J]. JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2016, 15 (03):
  • [6] Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations
    Ohliger, MA
    Grant, AK
    Sodickson, DK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 1018 - 1030
  • [7] Ultimate intrinsic signal-to-noise ratio in MRI
    Johns Hopkins University, School of Medicine, Department of Radiology, Baltimore, MD, United States
    不详
    [J]. Magn. Reson. Med., 3 (462-473):
  • [8] MEASURING SIGNAL-TO-NOISE RATIO IN TELECOMMUNICATION SYSTEMS
    BABIEL, W
    [J]. NACHRICHTENTECHNISCHE ZEITSCHRIFT, 1976, 29 (12): : 880 - 884
  • [9] Ultimate intrinsic signal-to-noise ratio in MRI
    Ocali, O
    Atalar, E
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (03) : 462 - 473
  • [10] SIGNAL-TO-NOISE RATIO IN IMAGES OF PARTIALLY COHERENT OBJECTS
    ELBAUM, M
    DIAMENT, P
    KING, M
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1975, 65 (10) : 1198 - 1199