A randomized comparison of right ventricular function after on-pump versus off-pump coronary artery bypass graft surgery

被引:23
|
作者
Michaux, Isabelle [1 ,2 ]
Filipovic, Miodrag [2 ]
Skarvan, Karl [2 ]
Bolliger, Daniel [2 ]
Schumann, Regina [2 ]
Bernet, Franziska [3 ]
Seeberger, Manfred D. [2 ]
机构
[1] Catholic Univ Louvain, Mt Godinne Univ Hosp, Dept Intens Care Med, B-1348 Louvain, Belgium
[2] Univ Basel Hosp, Dept Anesthesia, CH-4031 Basel, Switzerland
[3] Univ Basel Hosp, Dept Surg, Div Cardiothorac Surg, CH-4031 Basel, Switzerland
来源
关键词
TRICUSPID ANNULAR MOTION; CARDIOPULMONARY BYPASS; MAGNETIC-RESONANCE; EJECTION FRACTION; MYOCARDIAL INJURY; PERFORMANCE; REVASCULARIZATION; INDEXES; DISEASE; TRIAL;
D O I
10.1016/j.jtcvs.2010.02.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Right ventricular dysfunction occurs very soon after conventional coronary bypass surgery with cardiopulmonary bypass and might not recover within 1 year after the operation. It has been postulated that performing coronary surgery without cardiopulmonary bypass might preserve right ventricular function. We hypothesized that right ventricular global and overall systolic functions are better preserved 3 months after off-pump surgery than after conventional coronary bypass surgery. Methods: Fifty patients scheduled for elective coronary bypass surgery were randomly assigned to conventional or off-pump surgery. Right ventricular function was assessed by means of transthoracic echocardiographic analysis the day before the operation and 3 months later. Right ventricular myocardial performance index was used as a marker of global right ventricular function, and right ventricular fractional area change was used as a marker of overall right ventricular systolic function. Peak systolic velocities of the lateral tricuspid annulus were studied to assess regional systolic function of the right ventricular free wall. Results: Surgical intervention was completed according to randomization in 48 of 50 patients. Demographic and perioperative characteristics were similar in the 2 groups. Over the study period, right ventricular myocardial performance index and right ventricular fractional area change did not change in comparison with the baseline values in both groups. Peak systolic velocity of the lateral tricuspid annulus was decreased significantly in both groups 3 months after the operation. There were no significant intergroup differences in any echocardiographic marker of right ventricular function. Conclusions: Global right ventricular function was not better preserved 3 months after off-pump surgery than after conventional coronary bypass surgery. (J Thorac Cardiovasc Surg 2011;141:361-7)
引用
收藏
页码:361 / 367
页数:7
相关论文
共 50 条
  • [21] Technology insight: randomized trials of off-pump versus on-pump coronary artery bypass surgery
    Sundt, TM
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2005, 2 (05): : 261 - 268
  • [22] Technology Insight: randomized trials of off-pump versus on-pump coronary artery bypass surgery
    Thoralf M Sundt
    Nature Clinical Practice Cardiovascular Medicine, 2005, 2 : 261 - 268
  • [23] Temporal Pattern of Strokes After On-Pump and Off-Pump Coronary Artery Bypass Graft Surgery
    Nishiyama, Kei
    Horiguchi, Masahito
    Shizuta, Satoshi
    Doi, Takahiro
    Ehara, Natsuhiko
    Tanuguchi, Ryoji
    Haruna, Yoshizumi
    Nakagawa, Yoshihisa
    Furukawa, Yutaka
    Fukushima, Masanori
    Kita, Toru
    Kimura, Takeshi
    ANNALS OF THORACIC SURGERY, 2009, 87 (06): : 1839 - 1845
  • [24] Monocyte activation in on-pump versus off-pump coronary artery bypass surgery
    Greilich, Philip E.
    Brouse, Chad F.
    Rinder, Henry M.
    Jessen, Michael E.
    Rinder, Christine S.
    Eberhart, Robert C.
    Whitten, Charles W.
    Smith, Brian R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (03) : 361 - 368
  • [25] On-Pump versus Off-Pump Coronary-Artery Bypass Surgery.
    Shroyer, A. Laurie
    Grover, Frederick L.
    Hattler, Brack
    Collins, Joseph F.
    McDonald, Gerald O.
    Kozora, Elizabeth
    Lucke, John C.
    Baltz, Janet H.
    Novitzky, Dimitri
    NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (19): : 1827 - 1837
  • [26] On-pump versus off-pump coronary artery bypass grafting
    Gardner, Timothy J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (01): : 1 - 1
  • [27] On-pump versus off-pump coronary artery bypass: independent risk factors and off-pump graft patency
    Lund, O
    Christensen, J
    Holme, S
    Fruergaard, K
    Olesen, A
    Kassis, E
    Abildgaard, U
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (05) : 901 - 907
  • [28] Off-Pump Versus On-Pump Coronary Artery Bypass Grafting
    Moller, Christian H.
    Steinbruechel, Daniel A.
    CURRENT CARDIOLOGY REPORTS, 2014, 16 (03)
  • [29] Change in right ventricular function during off-pump coronary artery bypass graft surgery
    Kwak, YL
    Oh, YJ
    Jung, SM
    Yoo, KJ
    Lee, JH
    Hong, YW
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (04) : 572 - 577
  • [30] 2006 Effects of off-pump versus on-pump coronary artery bypass grafting on early and late right ventricular function
    Tammy J Pegg
    Theodoros D Karamitsos
    Ranjit J Arnold
    Jane M Francis
    Stefan Neubauer
    David P Taggart
    Joseph B Selvanayagam
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)