Interrater reliability of algometry in measuring pressure pain thresholds in healthy humans, using multiple raters

被引:504
|
作者
Chesterton, Linda S. [1 ]
Sim, Julius [1 ]
Wright, Christine C. [1 ]
Foster, Nadine E. [1 ]
机构
[1] Univ Keele, Primary Care Musculoskeletal Res Ctr, Keele ST5 5BG, Staffs, England
来源
CLINICAL JOURNAL OF PAIN | 2007年 / 23卷 / 09期
关键词
reliability; multiple raters; algometry; pressure pain threshold; quantitative sensory testing;
D O I
10.1097/AJP.0b013e318154b6ae
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To evaluate interrater reliability using 5 newly trained observers in the assessment of pressure pain threshold (PPT) using a fixed-angle algometer. Methods: The study design comprised 2 phases. Phase 1: 5 undergraduate physical therapists were trained in algometry at a predefined angle, at a rate of 5 Newtons (N)/s, to the first dorsal interosseous muscle. Each observer then underwent a competency test of the application speed. The aim was to achieve repeated applications at 5 N/s without visual feedback from the algometer. Phase 2: the 5 observers measured PPT of 13 healthy volunteers, at the first dorsal interosseous muscle. The sequence of observer measurements for each participant was randomized. Mean PPT values for each observer were analyzed using repeated measures analysis of variance, intraclass correlation coefficient (ICC2,1), and standard error of measurement, with 95% confidence intervals (CIs). Results: No significant differences between observers' mean values were found (P = 0.094), suggesting no bias. The ICC was 0.91 (95% CI 0.82, 0.97). The standard error of measurement value was 6.27 N/cm(2) (95% CI 5.35, 7.59). Differences in PPT measurements of more than 17.39 N/cm(2) (1.77 kg/cm(2)) are likely to exceed the magnitude of measurement error, and could be used to indicate true change. This margin of error is, however, somewhat larger than a previously proposed minimum clinically important difference in PPT of 14.71 N/cm(2) (1.5 kg/cm(2)). Discussion: This study provides new evidence that trained observers can apply an algometer at a consistent rate and provide highly reliable measures of PPT in healthy humans, when PPT is calculated as the mean of 3 trials.
引用
收藏
页码:760 / 766
页数:7
相关论文
共 50 条
  • [41] PRESSURE PAIN THRESHOLDS IN NORMAL MUSCLES - RELIABILITY, MEASUREMENT EFFECTS, AND TOPOGRAPHIC DIFFERENCES
    OHRBACH, R
    GALE, EN
    PAIN, 1989, 37 (03) : 257 - 263
  • [42] RELIABILITY AND VALIDITY OF THE PRESSURE PAIN THRESHOLDS (PPT) IN THE TMJ CAPSULES BY ELECTRONIC ALGOMETER
    CHUNG, SC
    KIM, JH
    KIM, HS
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 1993, 11 (03): : 171 - 176
  • [43] Pressure pain thresholds of tender point sites in patients with fibromyalgia and in healthy controls
    Maquet, D
    Croisier, JL
    Demoulin, C
    Crielaard, JM
    EUROPEAN JOURNAL OF PAIN, 2004, 8 (02) : 111 - 117
  • [44] Validity and reliability of measuring resting muscle sympathetic nerve activity using short sampling durations in healthy humans
    Notay, Karambir
    Seed, Jeremy D.
    Incognito, Anthony V.
    Doherty, Connor J.
    Nardone, Massimo
    Burns, Matthew J.
    Millar, Philip J.
    JOURNAL OF APPLIED PHYSIOLOGY, 2016, 121 (05) : 1065 - 1073
  • [45] Pressure pain in multiple sclerosis patients and in healthy subjects
    Armutlu, K
    Kerem, M
    Bumin, G
    Akbayrak, T
    Yigiter, K
    Keser, L
    Karabudak, R
    Kerimoglu, D
    PAIN CLINIC, 2002, 14 (02): : 147 - 151
  • [46] Reliability of pressure pain threshold testing (PPT) in healthy pain free young adults
    Arendt-Nielsen, Lars
    SCANDINAVIAN JOURNAL OF PAIN, 2015, 9 : 28 - 29
  • [47] Measuring pressure pain threshold in the cervical region of dizzy patientsThe reliability of a pressure algometer
    Knapstad, Mari Kalland
    Nordahl, Stein Helge Glad
    Naterstad, Ingvill Fjell
    Ask, Tove
    Skouen, Jan Sture
    Goplen, Frederik Kragerud
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2018, 23 (04)
  • [48] Interrater Agreement between Bedside and Video Raters Using the CPOT-Neuro for Pain Assessment in Critically Ill Patients with a Brain Injury
    Nguyen, Vivienne
    Richard-Lalonde, Melissa
    Gelinas, Celine
    NURSING REPORTS, 2024, 14 (01) : 212 - 219
  • [49] Measuring pressure pain thresholds. Comparison of an electromechanically controlled algometer with established methods
    Dagtekin, O.
    Koenig, E.
    Gerbershagen, H. J.
    Marcus, H.
    Sabatowski, R.
    Petzke, F.
    SCHMERZ, 2007, 21 (05): : 439 - 444
  • [50] A COMPUTER-PROGRAM FOR ASSESSING THE RELIABILITY OF NOMINAL SCALES USING VARYING SETS OF MULTIPLE RATERS
    CICCHETTI, DV
    HEAVENS, R
    DIDRIKSEN, J
    SHOWALTER, D
    EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1984, 44 (03) : 671 - 675