Interrater reliability of algometry in measuring pressure pain thresholds in healthy humans, using multiple raters

被引:504
|
作者
Chesterton, Linda S. [1 ]
Sim, Julius [1 ]
Wright, Christine C. [1 ]
Foster, Nadine E. [1 ]
机构
[1] Univ Keele, Primary Care Musculoskeletal Res Ctr, Keele ST5 5BG, Staffs, England
来源
CLINICAL JOURNAL OF PAIN | 2007年 / 23卷 / 09期
关键词
reliability; multiple raters; algometry; pressure pain threshold; quantitative sensory testing;
D O I
10.1097/AJP.0b013e318154b6ae
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To evaluate interrater reliability using 5 newly trained observers in the assessment of pressure pain threshold (PPT) using a fixed-angle algometer. Methods: The study design comprised 2 phases. Phase 1: 5 undergraduate physical therapists were trained in algometry at a predefined angle, at a rate of 5 Newtons (N)/s, to the first dorsal interosseous muscle. Each observer then underwent a competency test of the application speed. The aim was to achieve repeated applications at 5 N/s without visual feedback from the algometer. Phase 2: the 5 observers measured PPT of 13 healthy volunteers, at the first dorsal interosseous muscle. The sequence of observer measurements for each participant was randomized. Mean PPT values for each observer were analyzed using repeated measures analysis of variance, intraclass correlation coefficient (ICC2,1), and standard error of measurement, with 95% confidence intervals (CIs). Results: No significant differences between observers' mean values were found (P = 0.094), suggesting no bias. The ICC was 0.91 (95% CI 0.82, 0.97). The standard error of measurement value was 6.27 N/cm(2) (95% CI 5.35, 7.59). Differences in PPT measurements of more than 17.39 N/cm(2) (1.77 kg/cm(2)) are likely to exceed the magnitude of measurement error, and could be used to indicate true change. This margin of error is, however, somewhat larger than a previously proposed minimum clinically important difference in PPT of 14.71 N/cm(2) (1.5 kg/cm(2)). Discussion: This study provides new evidence that trained observers can apply an algometer at a consistent rate and provide highly reliable measures of PPT in healthy humans, when PPT is calculated as the mean of 3 trials.
引用
收藏
页码:760 / 766
页数:7
相关论文
共 50 条
  • [1] MEASURING INTERRATER RELIABILITY AMONG MULTIPLE RATERS - AN EXAMPLE OF METHODS FOR NOMINAL DATA
    POSNER, KL
    SAMPSON, PD
    CAPLAN, RA
    WARD, RJ
    CHENEY, FW
    STATISTICS IN MEDICINE, 1990, 9 (09) : 1103 - 1115
  • [2] INTERRATER AND INTERINSTRUMENT RELIABILITY OF PRESSURE PAIN THRESHOLDS IN NORMAL MUSCLE
    KAMER, AR
    CROW, HC
    OHRBACH, R
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 295 - 295
  • [3] A COMPARISON OF PRESSURE PAIN THRESHOLDS IN DIFFERENT TISSUES AND BODY REGIONS - LONG-TERM RELIABILITY OF PRESSURE ALGOMETRY IN HEALTHY-VOLUNTEERS
    KOSEK, E
    EKHOLM, J
    NORDEMAR, R
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1993, 25 (03): : 117 - 124
  • [4] Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis
    Mutlu, Ebru Kaya
    Ozdincler, Arzu Razak
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (06) : 1961 - 1965
  • [5] Interrater Reliability for Multiple Raters in Clinical Trials of Ordinal Scale
    Jungo Sawa
    Toshihiko Morikawa
    Drug information journal : DIJ / Drug Information Association, 2007, 41 : 595 - 605
  • [6] Interrater Reliability of the Adapted Fresno Test across Multiple Raters
    Lizarondo, Lucylynn M.
    Grimmer, Karen
    Kumar, Saravana
    PHYSIOTHERAPY CANADA, 2013, 65 (02) : 135 - 140
  • [7] Interrater reliability for multiple raters in clinical trials of ordinal scale
    Sawa, Jungo
    Morikawa, Toshihiko
    DRUG INFORMATION JOURNAL, 2007, 41 (05): : 595 - 605
  • [8] Reliability of Pressure Pain Thresholds in Healthy Young Adults
    Aytar, Aydan
    Senbursa, Gamze
    Baltaci, Gul
    Yuruk, Zeliha Ozlem
    Pekyavas, Nihan Ozunlu
    JOURNAL OF MUSCULOSKELETAL PAIN, 2014, 22 (03): : 225 - 231
  • [9] Interrater reliability of the OPI: Using academic trainee raters
    Halleck, GB
    FOREIGN LANGUAGE ANNALS, 1996, 29 (02) : 223 - 238
  • [10] Pain pressure threshold algometry of the abdominal wall in healthy women
    Montenegro, M. L. L. S.
    Braz, C. A.
    Mateus-Vasconcelos, E. L.
    Rosa-e-Silva, J. C.
    Candido-dos-Reis, F. J.
    Nogueira, A. A.
    Poli-Neto, O. B.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2012, 45 (07) : 578 - 582