Assessment of Inter- and Intra-Rater Reliability of Tablet-Based Software to Measure Cochlear Duct Length

被引:20
|
作者
Cooperman, Shayna P. [1 ]
Aaron, Ksenia A. [1 ]
Fouad, Ayman [1 ,2 ]
Tran, Emma [1 ]
Blevins, Nikolas H. [1 ]
Fitzgerald, Matthew B. [1 ]
机构
[1] Stanford Univ, Dept Otorhinolaryngol Head & Neck Surg, Stanford, CA 94305 USA
[2] Tanta Univ, Otolaryngol Dept, Tanta, Egypt
关键词
Cochlear duct length; Cochlear implant; Otoplan; ELECTRODE; ADAPTATION; PERCEPTION; MORPHOLOGY; PLACEMENT; INSERTION;
D O I
10.1097/MAO.0000000000003015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: The objective of this study is to build upon previous work validating a tablet-based software to measure cochlear duct length (CDL). Here, we do so by greatly expanding the number of cochleae (n = 166) analyzed, and examined whether computed tomography (CT) slice thickness influences reliability of CDL measurements. Study Design: Retrospective chart review study. Setting: Tertiary referral center. Patients: Eighty-three adult cochlear implant recipients were included in the study. Both cochleae were measured for each patient (n = 166). Interventions: Three raters analyzed the scans of 166 cochleae at 2 different time points. Each rater individually identified anatomical landmarks that delineated the basal turn diameter and width. These coordinates were applied to the elliptic approximation method (ECA) to estimate CDL. The effect of CT scan slice thickness on the measurements was explored. Main Outcome Measures: The primary outcome measure is the strength of the inter- and intra-rater reliability. Results: The mean CDL measured was 32.84 +/- 2.03 mm, with a range of 29.03 to 38.07 mm. We observed no significant relationship between slice thickness and CDL measurement (F1,164 = 3.04; p = 0.08). The mean absolute difference in CDL estimations between raters was 1.76 +/- 1.24 mm and within raters was 0.263 +/- 0.200 mm. The intra-class correlation coefficient (ICC) between raters was 0.54 and ranged from 0.63 to 0.83 within raters. Conclusions: This software produces reliable measurements of CDL between and within raters, regardless of CT scan thickness.
引用
收藏
页码:558 / 565
页数:8
相关论文
共 50 条
  • [31] Inter- and intra-rater reliability and agreement in determining subcutaneous tumour margins in dogs
    Ranganathan, B.
    Milovancev, M.
    Leeper, H.
    Townsend, K. L.
    Bracha, S.
    Curran, K.
    [J]. VETERINARY AND COMPARATIVE ONCOLOGY, 2018, 16 (03) : 392 - 398
  • [32] Inter- and intra-rater reliability of ultrasound tissue characterization (UTC) in patellar tendons
    van Ark, Mathijs
    Rabello, Lucas Maciel
    Hoevenaars, Dirk
    Meijerink, Joost
    van Gelderen, Niels
    Zwerver, Johannes
    van den Akker-Scheek, Inge
    [J]. SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2019, 29 (08) : 1205 - 1211
  • [33] Inter- and intra-rater reliability of vertebral fracture classifications in the Swedish fracture register
    Morgonskold, David
    Warkander, Victoria
    Savvides, Panayiotis
    Wihlborg, Axel
    Bouzereau, Mathilde
    Moller, Hans
    Gerdhem, Paul
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2019, 10 (01): : 14 - 22
  • [34] Inter- and intra-rater reliability for classification of medication related events in paediatric inpatients
    Kunac, D. L.
    Reith, D. M.
    Kennedy, J.
    Austin, N. C.
    Williams, S. M.
    [J]. QUALITY & SAFETY IN HEALTH CARE, 2006, 15 (03): : 196 - 201
  • [35] An exploration of the inter- and intra-rater reliability of the Bath Ankylosing Spondylitis Metrology Index
    Martindale, Jane H.
    Sutton, Chris J.
    Goodacre, Lynne
    [J]. CLINICAL RHEUMATOLOGY, 2012, 31 (11) : 1627 - 1631
  • [36] Degenerative findings on MRI of the cervical spine: an inter- and intra-rater reliability study
    Line Thorndal Moll
    Morten Wasmod Kindt
    Christina Malmose Stapelfeldt
    Tue Secher Jensen
    [J]. Chiropractic & Manual Therapies, 26
  • [37] A Study to Assess the Inter- and Intra-rater Reliability of the 5-Domain NPCCSS
    Patterson, M.
    Dali, I. C.
    Symonds, T.
    Guldberg, C.
    Hudgens, S.
    Mengel, E.
    [J]. ANNALS OF NEUROLOGY, 2019, 86 : S143 - S144
  • [38] Inter- and Intra-Rater Reliability of Occupational Exposure to Nickel and Cobalt as Assessed Retrospectively
    Jackson, L. W.
    Lawson, C. C.
    Lees, P. S.
    Breysee, P. N.
    Steward, P. A.
    Correa, A.
    [J]. EPIDEMIOLOGY, 2008, 19 (06) : S86 - S87
  • [39] Inter- and Intra-Rater Reliability of a Virtual Concussion Assessment During the Era of the COVID-19 Pandemic
    Jack, Alani
    Digney, Helena
    Bell, Carter
    Joseph, Binu
    Hyman, Sara
    Galetta, Steven
    Balcer, Laura
    Willer, Barry
    Haider, Mohammad
    Saleem, Ghazala
    Grossman, Scott
    Leddy, John
    Busis, Neil
    Torres, Daniel
    [J]. NEUROLOGY, 2023, 100 (17)
  • [40] Inter- and intra-rater reliability for measurement of range of motion in joints included in three hypermobility assessment methods
    Schlager, Angela
    Ahlqvist, Kerstin
    Rasmussen-Barr, Eva
    Bjelland, Elisabeth Krefting
    Pingel, Ronnie
    Olsson, Christina
    Nilsson-Wikmar, Lena
    Kristiansson, Per
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2018, 19