Assessment of the Accuracy of Infrared and Electromagnetic Navigation Using an Industrial Robot: Which Factors are Influencing the Accuracy of Navigation?

被引:10
|
作者
Liodakis, Emmanouil [1 ]
Chu, Kongfai [1 ]
Westphal, Ralf [2 ]
Krettek, Christian [1 ]
Citak, Musa [1 ]
Gosling, Thomas [1 ]
Kenawey, Mohamed [3 ]
机构
[1] Hannover Med Sch, Dept Trauma Surg, D-30627 Hannover, Germany
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Robot & Proc Control, D-38106 Braunschweig, Germany
[3] Sohag Univ Hosp, Dept Orthopaed Surg, Sohag 82524, Egypt
关键词
robot-assisted surgery; electromagnetic navigation; infrared navigation; accuracy; deformity; TOTAL KNEE ARTHROPLASTY; COMPUTER; RELIABILITY; ALIGNMENT;
D O I
10.1002/jor.21429
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Our objectives were to detect factors that influence the accuracy of surgical navigation (magnitude of deformity, plane of deformity, position of the navigation bases) and compare the accuracy of infrared with electromagnetic navigation. Human cadaveric femora were used. A robot connected with a computer moved one of the bony fragments in a desired direction. The bases of the infrared navigation (BrainLab) and the receivers of the electromagnetic device (Fastrak-Pohlemus) were attached to the proximal and distal parts of the bone. For the first part of the study, deformities were classified in eight groups (e.g., 0 to 5 degrees). For the second part, the bases were initially placed near the osteotomy and then far away. The mean absolute differences between both navigation system measurements and the robotic angles were significantly affected by the magnitude of angulation with better accuracy for smaller angulations (p < 0.001). The accuracy of infrared navigation was significantly better in the frontal and sagittal plane. Changing the position of the navigation bases near and far away from the deformity apex had no significant effect on the accuracy of infrared navigation; however, it influenced the accuracy of electromagnetic navigation in the frontal plane (p < 0.001). In conclusion, the use of infrared navigation systems for corrections of small angulation-deformities in the frontal or sagittal plane provides the most accurate results, irrespectively from the positioning of the navigation bases. (C) 2011 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 29:1476-1483, 2011
引用
收藏
页码:1476 / 1483
页数:8
相关论文
共 50 条
  • [1] Accuracy of Navigation: A Comparative Study of Infrared Optical and Electromagnetic Navigation
    Song, Eun Kyoo
    Seon, Jong Keun
    Park, Sang Jin
    Yoon, Taek Rim
    [J]. ORTHOPEDICS, 2008, 31 (10) : 76 - 81
  • [2] Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation
    Masaki Takao
    Hidetoshi Hamada
    Takashi Sakai
    Nobuhiko Sugano
    [J]. Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 189 - 195
  • [3] Factors influencing the accuracy of iliosacral screw insertion using 3D fluoroscopic navigation
    Takao, Masaki
    Hamada, Hidetoshi
    Sakai, Takashi
    Sugano, Nobuhiko
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (02) : 189 - 195
  • [4] Accuracy Improvement of Semantic Segmentation Using Appropriate Datasets for Robot Navigation
    Miyamoto, Ryusuke
    Adachi, Miho
    Nakamura, Yuta
    Nakajima, Takeshi
    Ishida, Hiroki
    Kobayashi, Shingo
    [J]. 2019 6TH INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT 2019), 2019, : 1610 - 1615
  • [5] Accuracy Using Static or Dynamic Navigation
    Block, Michael S.
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (01) : 2 - 3
  • [6] Accuracy assessment of the modern industrial robot
    Young, K
    Pickin, CG
    [J]. INDUSTRIAL ROBOT-AN INTERNATIONAL JOURNAL, 2000, 27 (06) : 427 - 436
  • [7] Clinical factors affecting the accuracy of a CT-based active infrared navigation system
    Liu, Yajun
    Zhao, Jingwei
    Fan, Mingxing
    Lv, Yanwei
    Liu, Wenyong
    Tian, Wei
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2016, 12 (03): : 568 - 571
  • [8] The Accuracy of an Electromagnetic Navigation System in Lateral Skull Base Approaches
    Komune, Noritaka
    Matsushima, Ken
    Matsuo, Satoshi
    Safavi-Abbasi, Sam
    Matsumoto, Nozomu
    Rhoton, Albert L., Jr.
    [J]. LARYNGOSCOPE, 2017, 127 (02): : 450 - 459
  • [9] Accuracy of intraoperative navigation using skin markers
    Darabi, K
    Grunert, P
    Perneczky, A
    [J]. CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 920 - 924
  • [10] Implant Placement Accuracy Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Lank, Kathryn
    Ryan, James
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 92 - 99