Use of solar PV inverters during night-time for voltage regulation and stability of the utility grid

被引:5
|
作者
Tharuka Lulbadda, Kushan [1 ]
Hemapala, Udayanga [1 ]
机构
[1] Univ Moratuwa, Dept Elect Engn, Moratuwa, Sri Lanka
来源
CLEAN ENERGY | 2022年 / 6卷 / 04期
关键词
solar; energy system and policy; energy storage; distributed energy and smart grid; photovoltaic; reactive power; night-time usage;
D O I
10.1093/ce/zkac042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Photovoltaic (PV) inverters are vital components for future smart grids. Although the popularity of PV-generator installations is high, their effective performance remains low. Certain inverters are designed to operate in volt-ampere reactive (VAR) mode during the night. Yet, this approach is ineffective due to the consumption of active power from the grid (as internal losses) and the regulation necessity of the direct-current (DC) bus. This paper will demonstrate the operation of a PV inverter in reactive power-injection mode when solar energy is unavailable. The primary focus is on the design of the inverter controller with respect to the synchronous rotating frame control method. The proposed novel method enables an inverter to inject the required level of reactive power to regulate the voltage levels of the utility grid within specified limits. In the process, the inverter does not absorb active power from the grid for its internal operation. The presented model has the ability to inject <= 2 kVAR of reactive power at zero power factor without absorbing active power from the grid. Simulation and hardware models of the inverter were developed and tested for different reactive loads in which the hardware model represented the real-world application. The reactive power injection of the two models ran at zero power factor and produced the expected outcomes for their corresponding independent reactive loads. Henceforth, it was evident that the proposed method can enhance the efficiency of an inverter and ensure the stability of the utility grid to which it is connected. This paper demonstrates, numerically and experimentally, the operation of a PV inverter in reactive power-injection mode when solar energy is unavailable. An inverter controller is designed with respect to the synchronous rotating frame control method. This can enhance the efficiency of an inverter and ensure the stability of the utility grid.
引用
收藏
页码:646 / 658
页数:13
相关论文
共 50 条
  • [41] Real-Time Monitoring Method of Power Grid Voltage Stability During Geomagnetic Storms
    Xin, Wen-Kai
    Liu, Chun-Ming
    Rezaei-Zare, Afshin
    Li, An-Qi
    Wang, Ze-Zhong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (01) : 192 - 201
  • [42] Converter Control During Low Voltage Ride Through Operation for Grid-Interfaced Solar PV Battery Assisted System
    Rai, Rashmi
    Singh, Bhim
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (09) : 9181 - 9191
  • [43] Scalable Single-Phase Multi-Functional Inverter for Integration of Rooftop Solar-PV to Low-Voltage Ideal and Weak Utility Grid
    Oruganti, Venkata Subrahmanya Raghavendra Varaprasad
    Dhanikonda, Venkata Sesha Samba Siva Sarma
    Simoes, Marcelo Godoy
    ELECTRONICS, 2019, 8 (03):
  • [44] 2-DOF Based Novel Controller Design for DC Voltage Regulation of LCL Interfaced Three Phase Grid Connected Solar PV System
    Tripathi, Ravi Nath
    Hanamoto, Tsuyoshi
    2015 IEEE 2ND INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC), 2015,
  • [45] Statistical study of the night-time F-layer dynamics at the magnetic equator in West Africa during the solar minimum period 1995-1997
    Tanoh, K. S.
    Adohi, B. J. -P.
    Coulibaly, I. S.
    Amory-Mazaudier, C.
    Kobea, A. T.
    Assamoi, P.
    ANNALES GEOPHYSICAE, 2015, 33 (01) : 143 - 157
  • [46] A London residential retrofit case study: Evaluating passive mitigation methods of reducing risk to overheating through the use of solar shading combined with night-time ventilation
    De Grussa, Zoe
    Andrews, Deborah
    Lowry, Gordon
    Newton, Elizabeth J.
    Yiakoumetti, Kika
    Chalk, Andrew
    Bush, David
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2019, 40 (04): : 389 - 408
  • [47] Energy Management Systems for Grid-Connected Houses with Solar PV and Battery by Considering Flat and Time-of-Use Electricity Rates
    Pan, Xincheng
    Khezri, Rahmat
    Mahmoudi, Amin
    Yazdani, Amirmehdi
    Shafiullah, G. M.
    ENERGIES, 2021, 14 (16)
  • [48] Adaptive discrete-time grid-voltage sensorless interfacing scheme for grid-connected DG-inverters based on neural-network identification and deadbeat current regulation
    Mohamed, Yasser Abdel-Rady Ibrahim
    El-Saadany, Ehab F.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (01) : 308 - 321
  • [49] The impact of street service care on frontline service utilisation during high-alcohol use hours in one night-time entertainment precinct in Australia
    Taylor, Nicholas
    Coomber, Kerri
    Curtis, Ashlee
    Mayshak, Richelle
    Harries, Travis
    Ferris, Jason
    Patafio, Brittany
    Hides, Leanne
    de Andrade, Dominique
    Miller, Peter
    DRUG AND ALCOHOL REVIEW, 2020, 39 (01) : 21 - 28
  • [50] Modified Finite Time Sliding Mode Controller for Automatic Voltage Regulation under Fast-Changing Atmospheric Conditions in Grid-Connected Solar Energy Systems
    Gulzar, Muhammad Majid
    Tehreem, Huma
    Khalid, Muhammad
    INTERNATIONAL JOURNAL OF INTELLIGENT SYSTEMS, 2023, 2023