Nanoporous gold as non-enzymatic sensor for hydrogen peroxide

被引:208
|
作者
Meng, Fanhui [2 ]
Yan, Xiuling [2 ,3 ]
Liu, Jianguo [1 ]
Gu, Jun [1 ]
Zou, Zhigang [1 ]
机构
[1] Nanjing Univ, Ecomat & Renewable Energy Res Ctr, Dept Mat Sci & Engn, Natl Lab Solid State Microstruct, Nanjing 210093, Jiangsu, Peoples R China
[2] Shandong Univ, Sch Chem & Chem Engn, Jinan 250100, Peoples R China
[3] Ili Normal Univ, Sch Chem & Biosci, Xinjiang 835000, Peoples R China
基金
美国国家科学基金会;
关键词
Nanoporous gold; Electrocatalysis; H(2)O(2) detection; H(2)O(2) sensor; Dealloying; ELECTROCATALYTIC REDUCTION; ELECTROCHEMICAL DETECTION; ELECTRODE; H2O2; OXIDATION; SURFACE; NANOPARTICLES; FABRICATION; MECHANISM; GLUCOSE;
D O I
10.1016/j.electacta.2011.02.105
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Nanoporous gold (NPG) fabricated by dealloying Au-Ag film was investigated for the non-enzymatic detection of H(2)O(2). The apparent activation energy of H(2)O(2) electrochemical reduction on NPG was found to be as low as similar to 30 kJ mol(-1). The reduction currents at -0.4V vs. SCE demonstrated a strict linear dependence in a wide H(2)O(2) concentration region from 10 mu M to 8 mM with a detection limit 3.26 mu M. Furthermore, the biosensor based on NPG exhibited high selectivity, good reproducibility, and long-term stability. These results indicate that NPG could be a promising electrochemical material for H(2)O(2) detection. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4657 / 4662
页数:6
相关论文
共 50 条
  • [31] Non-Enzymatic Electrochemical Hydrogen Peroxide Sensor Based on Copper Oxide Hollow Microspheres
    Shuai, Ying
    Liu, Chuanghua
    Wang, Jia
    Ma, Jun
    Cui, Xiaoyan
    [J]. SENSOR LETTERS, 2013, 11 (10) : 1945 - 1949
  • [32] Synthesis and characterization of non-enzymatic hydrogen peroxide sensor of polypyrrole coated cobalt nanocomposites
    Marimuthu, Tilagam
    Mahmoudian, M. R.
    Mohamad, Sharifah
    Alias, Yatimah
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 1037 - 1043
  • [33] Amperometric Non-Enzymatic Hydrogen Peroxide Sensor Based on Aligned Zinc Oxide Nanorods
    Al-Hardan, Naif H.
    Hamid, Muhammad Azmi Abdul
    Shamsudin, Roslinda
    Othman, Norinsan Kamil
    Keng, Lim Kar
    [J]. SENSORS, 2016, 16 (07)
  • [34] A novel non-enzymatic hydrogen peroxide sensor based on Co:ZnO modified electrodes
    Wang, Long
    Wu, Tong
    Wu, Han
    Zhong, Jun
    Wang, Ning
    Wang, Rongming
    [J]. PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2018, 28 (01) : 24 - 27
  • [35] Novel design of non-enzymatic sensor for rapid monitoring of hydrogen peroxide in water matrix
    Zakaria, A. B. M.
    Leszczynska, Danuta
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 766 : 30 - 36
  • [36] Nanoporous Pt(Au) Alloys for the Enhanced, Non-enzymatic Detection of Hydrogen Peroxide under Biofouling Conditions
    Khan, Rezaul K.
    Silva, Tiago A.
    Fatibello-Filho, Orlando
    Collinson, Maryanne M.
    Farghaly, Ahmed A.
    [J]. ELECTROANALYSIS, 2022, 34 (12) : 1893 - 1901
  • [37] A Non-Enzymatic Hydrogen Peroxide Sensor Based on Gold Nanoparticles/Carbon Nanotube/Self-Doped Polyaniline Hollow Spheres
    Chen, Xiaojun
    Guo, Buhua
    Hu, Pingping
    Wang, Yan
    [J]. ELECTROANALYSIS, 2014, 26 (07) : 1513 - 1521
  • [38] Highly branched gold–copper nanostructures for non-enzymatic specific detection of glucose and hydrogen peroxide
    Aroonsri Ngamaroonchote
    Yanisa Sanguansap
    Tuksadon Wutikhun
    Kullavadee Karn-orachai
    [J]. Microchimica Acta, 2020, 187
  • [39] Highly sensitive non-enzymatic hydrogen peroxide monitoring platform based on nanoporous gold via a modified solid-phase reaction method
    Yang, Zhipeng
    Li, Jun
    Liu, Panmei
    Zhang, An
    Wang, Jing
    Huang, Yuan
    Wang, Jiangyong
    Wang, Zumin
    [J]. RSC ADVANCES, 2021, 11 (58) : 36753 - 36759
  • [40] Nanostructured Gold Microelectrodes for Non-enzymatic Glucose Sensor
    Hovancova, Jana
    Sisolakova, Ivana
    Vanysek, Petr
    Orinakova, Renata
    Shepa, Ivan
    Vojtko, Marek
    Orinak, Andrej
    [J]. ELECTROANALYSIS, 2019, 31 (09) : 1680 - 1689