Minimally invasive guidewireless, navigated pedicle screw placement: a technical report and case series

被引:15
|
作者
Smith, Brandon W. [1 ]
Joseph, Jacob R. [1 ]
Kirsch, Michael [1 ]
Strasser, Mary Oakley [1 ]
Smith, Jacob [1 ]
Park, Paul [1 ]
机构
[1] Michigan Med, Dept Neurosurg, 1500 East Med Ctr Dr,Rm 3553 TC, Ann Arbor, MI 48109 USA
关键词
minimally invasive; spine; pedicle screw; navigation; K-wire; fusion; image guided; FIXATION; ACCURACY; SURGERY; FUSION; INSTRUMENTATION;
D O I
10.3171/2017.5.FOCUS17200
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Percutaneous pedicle screw insertion (PPSI) is a mainstay of minimally invasive spinal surgery. Traditionally, PPSI is a fluoroscopy-guided, multistep process involving traversing the pedicle with a Jamshidi needle, placement of a Kirschner wire (K-wire), placement of a soft-tissue dilator, pedicle tract tapping, and screw insertion over the K-wire. This study evaluates the accuracy and safety of PPSI with a simplified 2-step process using a navigated awl-tap followed by navigated screw insertion without use of a K-wire or fluoroscopy. METHODS Patients undergoing PPSI utilizing the K-wire-less technique were identified. Data were extracted from the electronic medical record. Complications associated with screw placement were recorded. Postoperative radiographs as well as CT were evaluated for accuracy of pedicle screw placement. RESULTS Thirty-six patients (18 male and 18 female) were included. The patients' mean age was 60.4 years (range 23.8-78.4 years), and their mean body mass index was 28.5 kg/m(2) (range 20.8-40.1 kg/m(2)). A total of 238 pedicle screws were placed. A mean of 6.6 pedicle screws (range 4-14) were placed over a mean of 2.61 levels (range 1-7). No pedicle breaches were identified on review of postoperative radiographs. In a subgroup analysis of the 25 cases (69%) in which CT scans were performed, 173 screws were assessed; 170 (98.3%) were found to be completely within the pedicle, and 3 (1.7%) demonstrated medial breaches of less than 2 mm (Grade B). There were no complications related to PPSI in this cohort. CONCLUSIONS This streamlined 2-step K-wire-less, navigated PPSI appears safe and accurate and avoids the need for radiation exposure to surgeon and staff.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Pedicle screw placement with use of a navigated surgical drill at subaxial cervical spine
    Satake, Kotaro
    Kanemura, Tokumi
    Ito, Kenyu
    Tanaka, Satoshi
    Morita, Yoshinori
    Nakashima, Hiroaki
    Ouchida, Jun
    Imagama, Shiro
    JOURNAL OF CLINICAL NEUROSCIENCE, 2021, 88 : 28 - 33
  • [32] A soft robotics approach for navigated pedicle screw placement: first experimental results
    Ortmaier, T.
    Weiss, H.
    Ott, C.
    Hirzinger, G.
    Schreiber, U.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 205 - 207
  • [33] Augmented reality-navigated pedicle screw placement: a cadaveric pilot study
    José Miguel Spirig
    Simon Roner
    Florentin Liebmann
    Philipp Fürnstahl
    Mazda Farshad
    European Spine Journal, 2021, 30 : 3731 - 3737
  • [34] Augmented reality-navigated pedicle screw placement: a cadaveric pilot study
    Spirig, Jose Miguel
    Roner, Simon
    Liebmann, Florentin
    Furnstahl, Philipp
    Farshad, Mazda
    EUROPEAN SPINE JOURNAL, 2021, 30 (12) : 3731 - 3737
  • [35] Navigated pedicle screw placement using computed tomographic data in dorsolumbar fractures
    Saurabh Kapoor
    Rajbahadur Sharma
    Sudhir Garg
    Rohit Jindal
    Ravi Gupta
    Anshul Goe
    Indian Journal of Orthopaedics, 2014, 48 : 555 - 561
  • [36] Navigated pedicle screw placement using computed tomographic data in dorsolumbar fractures
    Kapoor, Saurabh
    Sharma, Rajbahadur
    Garg, Sudhir
    Jindal, Rohit
    Gupta, Ravi
    Goe, Anshul
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (06) : 555 - 561
  • [37] Modified pedicle screw–rod fixation as a minimally invasive treatment for anterior pelvic ring injuries: an initial case series
    Xiaotian Wu
    Zuoqing Liu
    Wenqin Fu
    Shan Zhao
    Juntao Feng
    Journal of Orthopaedic Surgery and Research, 12
  • [38] Superior segment facet joint violation and cortical violation after minimally invasive pedicle screw placement
    Knox, Jeffrey B.
    Dai, Joseph M., III
    Orchowski, Joseph R.
    SPINE JOURNAL, 2011, 11 (03): : 213 - 217
  • [39] Comparison of the Percutaneous Screw Placement Precision of Isocentric C-arm 3-dimensional Fluoroscopy-navigated Pedicle Screw Implantation and Conventional Fluoroscopy Method With Minimally Invasive Surgery
    Nakashima, Hiroaki
    Sato, Kouji
    Ando, Toshihiro
    Inoh, Hidefumi
    Nakamura, Hiroshi
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (07): : 468 - 472
  • [40] Reduction in Radiation Exposure in Minimally Invasive Pedicle Screw Placement Using a Tubular Retractor: A Pilot Study
    Oki, Takeshi
    Lefor, Alan Kawarai
    Nakamura, Kentaro
    Higashi, Takahiro
    Oki, Isao
    TOMOGRAPHY, 2023, 9 (01) : 12 - 24