Minimally invasive guidewireless, navigated pedicle screw placement: a technical report and case series

被引:15
|
作者
Smith, Brandon W. [1 ]
Joseph, Jacob R. [1 ]
Kirsch, Michael [1 ]
Strasser, Mary Oakley [1 ]
Smith, Jacob [1 ]
Park, Paul [1 ]
机构
[1] Michigan Med, Dept Neurosurg, 1500 East Med Ctr Dr,Rm 3553 TC, Ann Arbor, MI 48109 USA
关键词
minimally invasive; spine; pedicle screw; navigation; K-wire; fusion; image guided; FIXATION; ACCURACY; SURGERY; FUSION; INSTRUMENTATION;
D O I
10.3171/2017.5.FOCUS17200
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Percutaneous pedicle screw insertion (PPSI) is a mainstay of minimally invasive spinal surgery. Traditionally, PPSI is a fluoroscopy-guided, multistep process involving traversing the pedicle with a Jamshidi needle, placement of a Kirschner wire (K-wire), placement of a soft-tissue dilator, pedicle tract tapping, and screw insertion over the K-wire. This study evaluates the accuracy and safety of PPSI with a simplified 2-step process using a navigated awl-tap followed by navigated screw insertion without use of a K-wire or fluoroscopy. METHODS Patients undergoing PPSI utilizing the K-wire-less technique were identified. Data were extracted from the electronic medical record. Complications associated with screw placement were recorded. Postoperative radiographs as well as CT were evaluated for accuracy of pedicle screw placement. RESULTS Thirty-six patients (18 male and 18 female) were included. The patients' mean age was 60.4 years (range 23.8-78.4 years), and their mean body mass index was 28.5 kg/m(2) (range 20.8-40.1 kg/m(2)). A total of 238 pedicle screws were placed. A mean of 6.6 pedicle screws (range 4-14) were placed over a mean of 2.61 levels (range 1-7). No pedicle breaches were identified on review of postoperative radiographs. In a subgroup analysis of the 25 cases (69%) in which CT scans were performed, 173 screws were assessed; 170 (98.3%) were found to be completely within the pedicle, and 3 (1.7%) demonstrated medial breaches of less than 2 mm (Grade B). There were no complications related to PPSI in this cohort. CONCLUSIONS This streamlined 2-step K-wire-less, navigated PPSI appears safe and accurate and avoids the need for radiation exposure to surgeon and staff.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] REDUCTION IN PEDICLE SCREW PLACEMENT TIME WITH A GUIDEWIRELESS PEDICLE SCREW SYSTEM FOR MINIMALLY INVASIVE SPINE SURGERY
    Greenleaf, R.
    Grossi, P.
    Erb, M.
    El-Sayegh, R.
    Pracyk, J. B.
    Marcini, A.
    VALUE IN HEALTH, 2021, 24 : S126 - S126
  • [2] Minimally invasive transforaminal lumbar interbody fusion with percutaneous navigated guidewireless lumbosacral pedicle screw fixation
    Chen, Kevin S.
    Park, Paul
    Neurosurgical Focus, 2016, 41
  • [3] REDUCTION IN PEDICLE SCREW PLACEMENT TIME WITH A NOVEL GUIDEWIRELESS PEDICLE SCREW SYSTEM FOR MINIMALLY INVASIVE SPINE SURGERY: INITIAL FINDINGS
    Grossi, P.
    Badin, M.
    Erb, M.
    Cirilli, L.
    Malone, D.
    Walsh, M.
    Menzie, A. M.
    Bhattacharyya, S. K.
    VALUE IN HEALTH, 2019, 22 : S223 - S223
  • [4] Navigated minimally invasive facet fusion during percutaneous lumbar pedicle screw insertion: Technical note
    Liu, Yi Lin
    Mehra, Ratnesh N.
    Chou, Dean
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 71 : 257 - 262
  • [5] Safety and efficacy of navigated trocarless pedicle screw placement: Technical note
    Umana, Giuseppe Emmanuele
    Scalia, Gianluca
    Perrone, Chiara
    Garaci, Francesco
    Pagano, Andrea
    De Luna, Adolfo
    Cicero, Salvatore
    Visocchi, Massimiliano
    Nicoletti, Giovanni Federico
    Germano, Antonino
    Lunardi, Pierpaolo
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2020, 21
  • [6] Percutaneous, Navigated Minimally Invasive Posterior Cervical Pedicle Screw Fixation
    Coric, Domagoj
    Rossi, Vincent J.
    Peloza, John
    Kim, Paul K.
    Adamson, Tim E.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2020, 14 : S14 - S21
  • [7] Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution
    Huntsman, Kade T.
    Ahrendtsen, Leigh A.
    Riggleman, Jessica R.
    Ledonio, Charles G.
    JOURNAL OF ROBOTIC SURGERY, 2020, 14 (01) : 199 - 203
  • [8] Robotic-assisted navigated minimally invasive pedicle screw placement in the first 100 cases at a single institution
    Kade T. Huntsman
    Leigh A. Ahrendtsen
    Jessica R. Riggleman
    Charles G. Ledonio
    Journal of Robotic Surgery, 2020, 14 : 199 - 203
  • [9] Navigated minimally invasive thoracolumbar pedicle screw placement with flat panel 3-D imaging. A feasibility study
    Citak, Musa
    Stubig, Timo
    Kendoff, Daniel
    Citak, Mustafa
    O'Loughlin, Padhraig F.
    Huefner, Tobias
    Krettek, Christian
    TECHNOLOGY AND HEALTH CARE, 2010, 18 (02) : 101 - 110
  • [10] Navigated odontoid screw placement using the O-arm: technical note and case series
    Pisapia, Jared M.
    Nayak, Nikhil R.
    Salinas, Ryan D.
    Macyszyn, Luke
    Lee, John Y. K.
    Lucas, Timothy H.
    Malhotra, Neil R.
    Chen, H. Isaac
    Schuster, James M.
    JOURNAL OF NEUROSURGERY-SPINE, 2017, 26 (01) : 10 - 18