Amperometric glucose-responding property of enzyme electrodes fabricated by covalent immobilization of glucose oxidase on conducting polymer films with macroporous structure

被引:8
|
作者
Liu, Chuanjun [1 ]
Ohta, Hokuto [1 ]
Kuwahara, Takashi [1 ]
Shimomura, Masato [1 ]
机构
[1] Nagaoka Univ Technol, Dept Bioengn, Fac Engn, Niigata 9402188, Japan
关键词
3-methylthiophene; thiophene-3-acetic acid; conducting polymer; glucose oxidase; enzyme electrode;
D O I
10.1016/j.eurpolymj.2008.01.003
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Macroporous conducting polymer films were prepared by the electrochemical copolymerization of 3-methylthiophene and thiophene-3-acetic acid on the ITO-coated glass plates bearing different sizes of polystyrene template particles, and enzyme electrodes were fabricated by covalent immobilization of glucose oxidase on the macroporous copolymer films. It was found that the doping level and conductivity of the copolymer films was significantly affected by the treatment with solvent to remove the polystyrene particles, which was considered to result in deterioration in amperometric glucose-responding property of the enzyme electrodes fabricated with the copolymer films. Three-dimensionally ordered macroporous structure on the copolymer films led to enhancement of amperometric response of the enzyme electrodes, and this effect was attributed to the geometry of the interconnected channel structure formed by the linkage of macropores. It was suggested that the amperometric response of the enzyme electrodes was determined by whether the interconnected channel structure on the copolymer films had long distance regularity and a proper size to allow the enzyme and electron-mediator molecules to penetrate into the interior pores of the copolymer film. In particular, the interconnected channel structure seemed to play an important role in the electron-transfer reaction between the mediator molecules and the surface of electrodes. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1114 / 1122
页数:9
相关论文
共 50 条
  • [21] Mediated glucose enzyme electrodes by cross-linking films of osmium redox complexes and glucose oxidase on electrodes
    Peter Ó Conghaile
    Sirisha Kamireddy
    Domhnall MacAodha
    Paul Kavanagh
    Dónal Leech
    Analytical and Bioanalytical Chemistry, 2013, 405 : 3807 - 3812
  • [22] Mediated glucose enzyme electrodes by cross-linking films of osmium redox complexes and glucose oxidase on electrodes
    Conghaile, Peter O.
    Kamireddy, Sirisha
    MacAodha, Domhnall
    Kavanagh, Paul
    Leech, Donal
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (11) : 3807 - 3812
  • [23] ELECTROCHEMICAL IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLY(AMPHIPHILIC PYRROLE) FILMS AND ITS APPLICATION TO THE PREPARATION OF AN AMPEROMETRIC GLUCOSE SENSOR
    COCHEGUERENTE, L
    DERONZIER, A
    MAILLEY, P
    MOUTET, JC
    ANALYTICA CHIMICA ACTA, 1994, 289 (02) : 143 - 153
  • [24] Covalent immobilization of glucose oxidase on the surface of polyaniline films graft copolymerized with acrylic acid
    Li, ZF
    Kang, ET
    Neoh, KG
    Tan, KL
    BIOMATERIALS, 1998, 19 (1-3) : 45 - 53
  • [25] Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: a glucose biosensor based on a co-crosslinked glucose oxidase overoxidized polypyrrole bilayer
    Guerrieri, A
    De Benedetto, GE
    Palmisano, F
    Zambonin, PG
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (01): : 103 - 112
  • [26] Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer
    Department of Chemistry and Chemical Engineering, Shanghai University, Shanghai
    200072, China
    不详
    Zhejiang Province
    310016, China
    Analytica Chimica Acta, 1999, 358 (02): : 137 - 144
  • [27] Amperometric biosensor sensitive to glucose and lactose based on co-immobilization of ferrocene, glucose oxidase, β-galactosidase and mutarotase in β-cyclodextrin polymer
    Liu, HY
    Li, HH
    Ying, TL
    Sun, K
    Qin, YQ
    Qi, DY
    ANALYTICA CHIMICA ACTA, 1998, 358 (02) : 137 - 144
  • [28] Amperometric enzyme electrodes for aerobic and anaerobic glucose monitoring prepared by glucose oxidase immobilized in mixed ferrocene-cobaltocenium dendrimers
    Alonso, B
    Armada, PG
    Losada, J
    Cuadrado, I
    González, B
    Casado, CM
    BIOSENSORS & BIOELECTRONICS, 2004, 19 (12): : 1617 - 1625
  • [29] A glucose amperometric sensor based on covalent immobilization of glucose oxidase in poly-2-aminoaniline film via chloranil on platinized platinum electrode
    Losada, J
    Armada, MPG
    ELECTROANALYSIS, 1997, 9 (18) : 1416 - 1421
  • [30] A Glucose Amperometric Sensor Based on Covalent Immobilization of Glucose Oxidase in Poly-2-aminoaniline Film via Chloranil on Platinized Platinum Electrode
    Losada, J.
    Garcia Armada, M. P.
    Electroanalysis, 9 (18):