Interobserver variability, and visual and quantitative parameters of 123I-FP-CIT SPECT (DaTSCAN) studies

被引:32
|
作者
Papathanasiou, Nikolaos [1 ]
Rondogianni, Phivi [1 ]
Chroni, Panagiota [1 ]
Themistocleous, Marios [2 ]
Boviatsis, Efstathios [2 ]
Pedeli, Xanthi [3 ]
Sakas, Damianos [2 ]
Datseris, Ioannis [1 ]
机构
[1] Evaggelismos Gen Hosp, Dept Nucl Med, Athens, Greece
[2] Evaggelismos Gen Hosp, Neurosurg Clin, Athens, Greece
[3] Univ Athens, Sch Med, Dept Hyg Epidemiol & Biostat, GR-11527 Athens, Greece
关键词
I-123-FP-CIT; DaTSCAN; Parkinson's disease; Interobserver variability; EMISSION COMPUTED-TOMOGRAPHY; PARKINSONIAN-SYNDROMES; MOVEMENT-DISORDERS; DAT-SPECT; LEWY BODY; DIAGNOSIS; DISEASE; I-123-IOFLUPANE; ACCURACY; DEMENTIA;
D O I
10.1007/s12149-011-0564-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the degree of interobserver agreement in the visual interpretation of I-123-FP-CIT studies and to investigate for potential associations between visual and semi-quantitative parameters. Eighty-nine I-123-FP-CIT studies were blindly reviewed by 3 independent observers: a consultant, a resident doctor and a radiographer. They classified every study as either "normal" or "abnormal" and assigned visual I-123-FP-CIT uptake scores (2: normal, 1: reduced and 0: no uptake) in basal ganglia nuclei (right and left putamina and caudate nuclei) on every scan. Striatal I-123-FP-CIT binding ratios were calculated using crescent-ROI software. The interobserver agreement for the interpretation of studies and for visual score assignment was evaluated by means of kappa statistics. We investigated for associations of binding ratios with visual scores and clinical parameters; patients' clinical diagnoses served as the reference standard. There was excellent interobserver agreement (kappa 0.89-0.93) in classifying studies as "normal" or "abnormal" and fine agreement in assignment of visual scores (kappa 0.71-0.80 for putamina and 0.50-0.79 for caudate nuclei). Nuclei with scores of 1 and 0 showed significantly reduced binding ratios (about 30 and 50%, respectively) compared with the nuclei scored as 2. ROC analysis indicated the optimal cutoff point of striatal binding ratio at 3.8 (sensitivity 98.5%, specificity 95%) for the detection of parkinsonian syndromes. Striatal binding ratios were negatively associated with age in normal subjects and disease duration in Parkinson's disease patients. Visual interpretation of I-123-FP-CIT studies showed very good interobserver agreement. We found significant associations among visual, semi-quantitative and clinical parameters.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 50 条
  • [41] Technical factors affecting 123I-FP-CIT presynaptic dopamine transporter (DaT) SPECT studies
    Nichols, Kenneth
    Tomas, Maria-Bernadette
    Palestro, Christopher
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [42] Added value of combined semi-quantitative and visual 123I-FP-CIT SPECT analyses for the diagnosis of dementia with Lewy bodies
    Nicastro, N.
    Garibotto, V.
    Allali, G.
    Assal, F.
    Burkhard, P. R.
    SWISS MEDICAL WEEKLY, 2016, 146 : 98S - 98S
  • [43] Is Occipital Cortex a Valid Reference Region in 123I-FP-CIT SPECT Imaging?
    Joutsa, Juho
    Johansson, Jarkko
    Kaasinen, Valtteri
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (07) : 615 - 616
  • [44] Focal 123I-FP-CIT SPECT abnormality in a patient with midbrain vascular Parkinsonism
    Solla, P.
    Cannas, A.
    Orofino, G.
    Arca, R.
    Meloni, M.
    Fonti, D.
    Marrosu, F.
    MOVEMENT DISORDERS, 2015, 30 : S329 - S330
  • [45] Reproducibility of the semi-quantitative assessment of 123I-FP-CIT SPECT using striatal analysis software
    Nakajima, N.
    Hokama, H.
    Seno, T.
    Shitara, S.
    Itagaki, R.
    Ueda, M.
    Kimura, K.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 381 : 808 - 808
  • [46] Diagnostic accuracy of 123I-FP-CIT SPECT in possible dementia with Lewy bodies
    O'Brien, John T.
    McKeith, Ian G.
    Walker, Zuzana
    Tatsch, Klaus
    Booij, Jan
    Darcourt, Jacques
    Marquardt, Moritz
    Reininger, Cornelia
    BRITISH JOURNAL OF PSYCHIATRY, 2009, 194 (01) : 34 - 39
  • [47] Acquisition count dependence of the specific binding ratio in 123I-FP-CIT SPECT
    Kita, Akinobu
    Okazawa, Hidehiko
    Sugimoto, Katsuya
    Kaido, Ryoto
    Kosaka, Nobuyuki
    Shibutani, Takayuki
    Onoguchi, Masahisa
    Kidoya, Eiji
    Kimura, Hirohiko
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (12) : 1271 - 1278
  • [48] Application of CT based spatial normalization by DARTEL to quantitative assessment of 123I-FP-CIT SPECT.
    Yokoyama, K.
    Imabayashi, E.
    Matsuda, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S562 - S562
  • [49] Acquisition Count Dependence of Specific Binding Ratio in 123I-FP-CIT SPECT
    Kita, Akinobu
    Okazawa, Hidehiko
    Sugimoto, Katsuya
    Kaido, Ryoto
    Kidoya, Eiji
    Kimura, Hirohiko
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [50] 123I-FP-CIT SPECT usefulness in early stage Parkinson's Disease
    Nuvoli, S.
    Agnetti, V.
    Paulus, K.
    Sanna, L.
    Falchi, A.
    Chessa, F.
    Spanu, A.
    Madeddu, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S191 - S191