Interobserver variability, and visual and quantitative parameters of 123I-FP-CIT SPECT (DaTSCAN) studies

被引:32
|
作者
Papathanasiou, Nikolaos [1 ]
Rondogianni, Phivi [1 ]
Chroni, Panagiota [1 ]
Themistocleous, Marios [2 ]
Boviatsis, Efstathios [2 ]
Pedeli, Xanthi [3 ]
Sakas, Damianos [2 ]
Datseris, Ioannis [1 ]
机构
[1] Evaggelismos Gen Hosp, Dept Nucl Med, Athens, Greece
[2] Evaggelismos Gen Hosp, Neurosurg Clin, Athens, Greece
[3] Univ Athens, Sch Med, Dept Hyg Epidemiol & Biostat, GR-11527 Athens, Greece
关键词
I-123-FP-CIT; DaTSCAN; Parkinson's disease; Interobserver variability; EMISSION COMPUTED-TOMOGRAPHY; PARKINSONIAN-SYNDROMES; MOVEMENT-DISORDERS; DAT-SPECT; LEWY BODY; DIAGNOSIS; DISEASE; I-123-IOFLUPANE; ACCURACY; DEMENTIA;
D O I
10.1007/s12149-011-0564-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the degree of interobserver agreement in the visual interpretation of I-123-FP-CIT studies and to investigate for potential associations between visual and semi-quantitative parameters. Eighty-nine I-123-FP-CIT studies were blindly reviewed by 3 independent observers: a consultant, a resident doctor and a radiographer. They classified every study as either "normal" or "abnormal" and assigned visual I-123-FP-CIT uptake scores (2: normal, 1: reduced and 0: no uptake) in basal ganglia nuclei (right and left putamina and caudate nuclei) on every scan. Striatal I-123-FP-CIT binding ratios were calculated using crescent-ROI software. The interobserver agreement for the interpretation of studies and for visual score assignment was evaluated by means of kappa statistics. We investigated for associations of binding ratios with visual scores and clinical parameters; patients' clinical diagnoses served as the reference standard. There was excellent interobserver agreement (kappa 0.89-0.93) in classifying studies as "normal" or "abnormal" and fine agreement in assignment of visual scores (kappa 0.71-0.80 for putamina and 0.50-0.79 for caudate nuclei). Nuclei with scores of 1 and 0 showed significantly reduced binding ratios (about 30 and 50%, respectively) compared with the nuclei scored as 2. ROC analysis indicated the optimal cutoff point of striatal binding ratio at 3.8 (sensitivity 98.5%, specificity 95%) for the detection of parkinsonian syndromes. Striatal binding ratios were negatively associated with age in normal subjects and disease duration in Parkinson's disease patients. Visual interpretation of I-123-FP-CIT studies showed very good interobserver agreement. We found significant associations among visual, semi-quantitative and clinical parameters.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 50 条
  • [1] Interobserver variability, and visual and quantitative parameters of 123I-FP-CIT SPECT (DaTSCAN) studies
    Nikolaos Papathanasiou
    Phivi Rondogianni
    Panagiota Chroni
    Marios Themistocleous
    Efstathios Boviatsis
    Xanthi Pedeli
    Damianos Sakas
    Ioannis Datseris
    Annals of Nuclear Medicine, 2012, 26 : 234 - 240
  • [2] 123I-FP-CIT SPECT (DaTSCAN): interobserver variability and correlation with quantitative parameters
    Papathanasiou, N.
    Rondogianni, P.
    Chroni, P.
    Vlontzou, E.
    Housianakou, I.
    Giannopoulou, C.
    Datseris, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S307 - S307
  • [3] Automatic classification of 123I-FP-CIT (DaTSCAN) SPECT images
    Towey, David J.
    Bain, Peter G.
    Nijran, Kuldip S.
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (08) : 699 - 707
  • [4] Cross-system correction factor in 123I-FP-CIT SPECT DaTscan
    Knudsen, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S658 - S658
  • [5] Effects of different reconstruction methods on 123I-FP-CIT (DaTSCAN) SPECT quantification
    Smith, A.
    Niedbala, J.
    Dewaraja, Y.
    Dickson, J. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S607 - S608
  • [6] Interobserver agreement in the visual and semi-quantitative analysis of the 123I-FP-CIT SPECT images in the diagnosis of Parkinsonian syndrome
    Suarez-Pinera, M.
    Prat, M. L.
    Mestre-Fusco, A.
    Fuertes, J.
    Mojal, S.
    Balaguer, E.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2011, 30 (04): : 229 - 235
  • [7] 123I-FP-CIT SPECT imaging in blepharospasm
    De Verdal, M.
    Renard, D.
    Collombier, L.
    Castelnovo, G.
    REVUE NEUROLOGIQUE, 2017, 173 (10) : 645 - 649
  • [8] Differentiation of drug-induced parkinsonism and PD; Utility of 123I-FP-CIT SPECT(DaTscan)
    Tachibana, K.
    Hlrata, Y.
    Katoh, N.
    Ishikawa, H.
    Shimada, T.
    Shindo, A.
    Matsuura, K.
    Asahi, M.
    Satoh, M.
    Li, Y.
    Taniguchi, A.
    Tomimoto, H.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 381 : 954 - 954
  • [9] Semiquantitative slab view display for visual evaluation of 123I-FP-CIT SPECT
    Buchert, Ralph
    Hutton, Chloe
    Lange, Catharina
    Hoppe, Peter
    Makowski, Marcus
    Bamousa, Thamer
    Platsch, Guenther
    Brenner, Winfried
    Declerck, Jerome
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (05) : 509 - 518
  • [10] 123I-FP-CIT (DaTSCAN) scintigraphy in the diagnosis of Parkinson's disease
    Liepe, K.
    Sixel-Doering, F.
    Trenkwalder, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S383 - S384