Clinical outcomes of revision with retrograde intermedullary nailing for failed plating of distal femoral fractures: a retrospective study

被引:3
|
作者
Yuan, Yi [1 ]
Luo, Bing [1 ]
Hao, Qi [1 ]
Yuan, Jun [1 ]
Qu, Gang-bo [1 ]
Hao, Pan-deng [1 ]
Zeng, Zhi-jiang [1 ]
Yang, Jia-fu [1 ]
Xu, Zu-jian [1 ]
机构
[1] Southwest Med Univ, Tradit Chinese Med Hosp, Dept Orthopaed, 182 Chunhui Rd, Luzhou 646000, Sichuan, Peoples R China
关键词
Distal femoral fracture; Locking compression plate; Failure; retrograde intramedullary nail; Revision; INVASIVE STABILIZATION SYSTEM; INTRAMEDULLARY NAIL; FEMUR FRACTURES; EPIDEMIOLOGY; FIXATION;
D O I
10.1007/s00264-020-04621-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To assess the feasibility and effectiveness of retrograde intramedullary nail (RIN) revision surgeries for locking compression plate (LCP) failure in distal femoral fractures. Methods This retrospective study included 13 patients who suffered from metalwork failures after they initially underwent open reduction and LCP fixation. In patients who eventually underwent RIN revision from January 2014 to December 2016, range of motion (ROM) and Hospital for Special Surgery (HSS) scores obtained before surgery and at the final follow-up time were analysed. Results The average operative time was 155 minutes (range, 120-210 minutes), and the average blood loss volume was 650 ml (range, 200-1350 ml). There were two cases of complications (15.38%): one was calf muscle vein thrombosis, and the other was a superficial infection. No deep tissue infection or deep vein thrombosis was observed post-operatively. The average follow-up time was 16 months (range, 12-24 months). All fractures healed in a mean of 6.5 months (range, 4-12 months), and one patient underwent an additional bone graft surgery that did not involve a bone graft during the RIN revision operation (this eventually healed at 12 months post-operatively). The mean ROM before the operation was 86.92 +/- 12.34 degrees. At the final follow-up, the mean ROM was 112.69 +/- 9.27 degrees. There was a significant difference between pre-operative and post-operative ROM (P < 0.01). The mean HSS score improved significantly from 38.85 +/- 9.62 points pre-operatively to 79.62 +/- 5.42 points post-operatively. There was a significant difference between pre-operative and post-operative HSS scores (P < 0.01). Conclusions RIN revision surgery achieved excellent clinical results in patients with LCP failure.
引用
收藏
页码:2437 / 2442
页数:6
相关论文
共 50 条
  • [41] Retrograde intramedullary nailing of femoral shaft fractures. A prospective study
    Holmenschlager, F
    Piatek, S
    Halm, JP
    Winckler, S
    UNFALLCHIRURG, 2002, 105 (12): : 1100 - 1108
  • [42] Periprosthetic Distal Femoral Fractures Around a Total Knee Arthroplasty: a Meta-analysis Comparing Locking compression Plating and Retrograde Intramedullary Nailing
    Al-Jabri, Talal
    Wood, Matthew J.
    Faddul, Farah
    Musbahi, Omar
    Bajracharya, Abhijit
    Magan, Ahmed A.
    Jayadev, Chethan
    Giannoudis, Peter V.
    ORTHOPEDIC REVIEWS, 2024, 16
  • [43] Knee Pain and Functional Outcomes after Retrograde Femoral Nailing: A Retrospective Review
    Breyer, Garrett
    Usmani, Kudret
    Hwang, Rock
    Begley, Brian
    Mashru, Rakesh P.
    Gutowski, Christina J.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (03): : 219 - 225
  • [44] Outcomes of Retrograde Femoral Nail Osteosynthesis of Intraarticular Fractures of the Distal Femur
    Zeman, J.
    Korpa, P.
    Matejka, T.
    Zeman, P.
    Matejka, J.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2024, 91 (06)
  • [45] Comparison of retrograde intramedullary nailing and bridge plating in the treatment of extra-articular fractures of the distal femur
    Demirtas, Abdullah
    Azboy, Ibrahim
    Ozkul, Emin
    Gem, Mehmet
    Alemdar, Celil
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (05) : 521 - 526
  • [46] Intramedullary nailing versus percutaneous locked plating of distal extra-articular tibial fractures: A retrospective study
    Seyhan M.
    Unay K.
    Sener N.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (5) : 595 - 601
  • [47] Clinical outcomes of treatment with locking compression plates for distal femoral fractures in a retrospective cohort
    Kiyono, Masahiro
    Noda, Tomoyuki
    Nagano, Hiroshi
    Maehara, Takashi
    Yamakawa, Yasuaki
    Mochizuki, Yusuke
    Uchino, Takahiko
    Yokoo, Suguru
    Demiya, Koji
    Saiga, Kenta
    Shimamura, Yasunori
    Ozaki, Toshifumi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [48] Clinical outcomes of treatment with locking compression plates for distal femoral fractures in a retrospective cohort
    Masahiro Kiyono
    Tomoyuki Noda
    Hiroshi Nagano
    Takashi Maehara
    Yasuaki Yamakawa
    Yusuke Mochizuki
    Takahiko Uchino
    Suguru Yokoo
    Koji Demiya
    Kenta Saiga
    Yasunori Shimamura
    Toshifumi Ozaki
    Journal of Orthopaedic Surgery and Research, 14
  • [49] Nailing or plating for subtrochanteric femoral fractures: a non-randomized comparative study
    Imerci A.
    Canbek U.
    Karatosun V.
    Karapınar L.
    Yeşil M.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (5) : 889 - 894
  • [50] Comparative study of retrograde intramedullary nailing versus locking extramedullary plating in complete articular fractures with metaphyseal comminution of the distal femur
    Yoon, Yong-Cheol
    Kim, Youngwoo
    Pesante, Benjamin D.
    Chun, You Seung
    Lee, Sang Ho
    Sohn, Hoon-Sang
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2109 - 2118