Neck-bridge device for endovascular treatment of wide-neck bifurcation aneurysms: Initial experience

被引:78
|
作者
Raymond, J [1 ]
Guilbert, F [1 ]
Roy, D [1 ]
机构
[1] Univ Montreal, Notre Dame Hosp, Ctr Hosp, Dept Radiol, Montreal, PQ H2L 4M1, Canada
关键词
aneurysm; basilar; therapy; angiography; interventional procedures;
D O I
10.1148/radiol.2212010474
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To report the authors' initial experience in treating patients with wide-neck aneurysms with assistance from a recently developed neck-bridge device (TriSpan; Target Therapeutics/Boston Scientific, Fremont, Calif). MATERIALS AND METHODS: Twenty-five patients were examined. Aneurysms were most frequently at the basilar bifurcation (n = 19). Sixteen aneurysms were treated electively: six aneurysms that recurred after coil-only embolization and 10 nontreated aneurysms (including four that had failed coil-only embolization). Nine aneurysms were treated acutely following subarachnoid hemorrhage. All lesions except one had a wide neck. A dual-catheter technique was used in 23 patients. Immediate angiographic results, technical incidents, and complications were recorded. Follow-up angiography was performed in 16 patients. Clinical follow-up ranged from 1 to 12 months. RESULTS: Neck-bridge device-assisted coil packing was successfully performed in 23 lesions, with complete obliteration in three, residual necks in 13, and a minimal residual sac in seven patients. Parent vessel protection failed, with coil protrusion and arterial occlusion, in one of these patients. Other complications that were not directly related to use of the neck-bridge device included retroperitoneal hematoma, rebleeding, coil perforation, and transient embolic arterial occlusion. One patient died of vasospasm and heart failure. Follow-up angiography revealed complete obliteration in four, a residual neck in one, a persistent residual sac in four, and recurrent aneurysm in seven patients. One patient had a small occipital infarction 5 weeks after treatment. CONCLUSION: The described neck-bridge device is useful for assisting coil embolization of wide-neck bifurcation aneurysms.
引用
收藏
页码:318 / 326
页数:9
相关论文
共 50 条
  • [31] Neck-bridge device for combined endovascular and surgical treatment of a giant anterior communicating artery aneurysm
    Charbel Mounayer
    Per Undrén
    Michel Piotin
    Hervé Boissonnet
    Jacques Moret
    Neuroradiology, 2005, 47 : 295 - 299
  • [32] Neck-bridge device for combined endovascular and surgical treatment of a giant anterior communicating artery aneurysm
    Mounayer, C
    Undrén, P
    Piotin, M
    Boissonnet, H
    Moret, J
    NEURORADIOLOGY, 2005, 47 (04) : 295 - 299
  • [33] Stents and Stent Mimickers in Endovascular Management of Wide-neck Intracranial Aneurysms
    Khattak, Yasir J.
    Sibaie, Ayman A.
    Anwar, Muhammad
    Sayani, Raza
    CUREUS, 2018, 10 (10):
  • [34] Endovascular treatment of experimental wide neck aneurysms: Comparison of results using coils or cyanoacrylate with the assistance of an aneurysm neck bridge device
    Raymond, J
    Salazkin, I
    Georganos, S
    Guilbert, F
    Desfaits, AC
    Gevry, G
    Weill, A
    Roy, D
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (10) : 1710 - 1716
  • [35] Early experience with a temporary bridging device (Comaneci) in the endovascular treatment of ruptured wide neck aneurysms
    Sirakov, Stanimir
    Sirakov, Alexander
    Hristov, Hristo
    Minkin, Krasimir
    Penkov, Marin
    Karakostov, Vasil
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (10) : 978 - 982
  • [36] Endovascular treatment of wide-neck intracranial bifurcation aneurysms with 'Y'-configuration, double Neuroform® stents-assisted coiling technique: Experience in a single center
    Castano, C.
    Terceno, M.
    Remollo, S.
    Garcia-Sort, M. R.
    Dominguez, C.
    INTERVENTIONAL NEURORADIOLOGY, 2017, 23 (04) : 362 - 370
  • [37] Y-stenting with braided stents for wide-neck intracranial bifurcation aneurysms. A single-center initial experience
    Mihalea, Cristian
    Caroff, Jildaz
    Ikka, Leon
    Benachour, Nidhal
    Da Ros, Valerio
    Abdelkhalek, Hazem
    Iacobucci, Marta
    Marenco de la Torre, Joaquin Jose
    Pagiola, Igor
    Yasuda, Thomas
    Popa, Bogdan Valeriu
    Ples, Horia
    Pescariu, Sorin
    Moret, Jacques
    Spelle, Laurent
    JOURNAL OF NEURORADIOLOGY, 2020, 47 (03) : 227 - 232
  • [38] Modifying flow in the ACA-ACoA complex: endovascular treatment option for wide-neck internal carotid artery bifurcation aneurysms
    Nossek, Erez
    Chalif, David J.
    Levine, Mitchell
    Setton, Avi
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (05) : 351 - 356
  • [39] Microsurgical clipping vs Woven EndoBridge (WEB) device for the management of unruptured wide-neck bifurcation aneurysms
    Tatiana Chacón-Quesada
    Dorothee Mielke
    Veit Rohde
    Silvia Hernández-Durán
    Neurosurgical Review, 2022, 45 : 2717 - 2722
  • [40] Treatment of Wide-Neck Intracranial Aneurysms with the Woven EndoBridge Device Associated with Stenting: A Single-Center Experience
    Cagnazzo, F.
    Ahmed, R.
    Dargazanli, C.
    Lefevre, P-H
    Gascou, G.
    Derraz, I
    Kalmanovich, S. A.
    Riquelme, C.
    Bonafe, A.
    Costalat, V
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : 820 - 826