Sodium vapor pressure losses in a multitube, alkali-metal thermal-to-electric converter

被引:11
|
作者
Tournier, JM [1 ]
El-Genk, MS [1 ]
机构
[1] Univ New Mexico, Inst Space Nucl Power Studies, Dept Chem & Nucl Engn, Albuquerque, NM 87131 USA
关键词
D O I
10.2514/2.6408
中图分类号
O414.1 [热力学];
学科分类号
摘要
A model was developed to calculate the vapor pressure Losses and characterize the vapor flow regimes on the cathode side of a multitube, vapor-anode, alkali-metal thermal-to-electric converter (AMTEC) cell, with internal chevron's radiation shields. The dusty gas model was used to predict the vapor now over a wide range of pressures, including the free-molecular, transition, and continuum now regimes. Results showed that the vapor how on the cathode side of a multitube AMTEC cell is typically in the transition regime, and that the pressure loss in the chevron's shield accounts for about 50% of the total pressure losses. An analysis is also performed to optimize the conical chevron's geometry for minimum pressure loss.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 50 条