Diagnostic accuracy of palpation versus ultrasound-guided fine needle aspiration biopsy for diagnosis of malignancy in thyroid nodules: a systematic review and meta-analysis

被引:17
|
作者
Tarigan, Tri Juli Edi [1 ,2 ]
Anwar, Budiman Syaeful [3 ]
Sinto, Robert [4 ]
Wisnu, Wismandari [1 ,2 ]
机构
[1] Univ Indonesia, Dr Cipto Mangunkusumo Natl Gen Hosp, Div Endocrinol Metab & Diabet, Dept Internal Med,Fac Med, Jakarta, Indonesia
[2] Univ Indonesia, Indonesian Med Educ & Res Inst, Metab Cardiovasc & Aging Cluster, Fac Med, Jakarta, Indonesia
[3] Univ Indonesia, Dr Cipto Mangunkusumo Natl Gen Hosp, Fac Med, Dept Internal Med, Jakarta, Indonesia
[4] Univ Indonesia, Dr Cipto Mangunkusumo Natl Referral Hosp, Div Infect & Trop Dis, Dept Internal Med,Fac Med, Jakarta, Indonesia
关键词
Fine-needle aspiration biopsy; Palpable versus USG guided; Thyroid nodules; RELIABILITY; MANAGEMENT; CYTOLOGY;
D O I
10.1186/s12902-022-01085-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Thyroid nodule is a common health problem in endocrinology. Thyroid fine-needle aspiration biopsy (FNAB) cytology performed by palpation guided FNAB (PGFNAB) and ultrasound-guided FNAB (USGFNAB) are the preferred examinations for the diagnosis of thyroid cancer and part of the integration of the current thyroid nodule assessment. Although studies have shown USGFNAB to be more accurate than PGFNAB, inconsistencies from several studies and clinical guidelines still exist. The purpose of this study is to compare the diagnostic accuracy of Palpation versus Ultrasound-Guided Fine Needle Aspiration Biopsy in diagnosing malignancy of thyroid nodules. The systematic review and meta-analysis were prepared based on the PRISMA standards. Literature searches were carried out on three online databases (Pubmed/MEDLINE, Embase, and Proquest) and grey literatures. Data extraction was carried out manually from various studies that met the eligibility, followed by analysis to obtain pooled data on sensitivity, specificity, Diagnostic Odds Ratio (DOR) and Area Under Curve (AUC), and the comparison of the two methods. Total of 2517 articles were obtained, with 11 studies were included in this systematic review. The total sample was 2382, including 1128 subjects using PGFNAB and 1254 subjects using USGFNAB. The risk of bias was assessed using QUADAS-2 with mild-moderate results. The results of sensitivity, specificity, AUC and DOR in diagnosing thyroid nodules using PGFNAB were 76% (95% CI, 49-89%), 77% (95% CI, 56-95%), 0.827 and 11.6 (95% CI, 6-21) respectively. The results of sensitivity, specificity, AUC and DOR in diagnosing thyroid nodules using USGFNAB were 90% (95% CI, 81-95%), 80% (95% CI, 66-89%), 0.92 and 40 (95% CI, 23-69), respectively the results of the comparison test between PGFNAB and USGFNAB; Tsens USGFNAB of 0.99 (p = 0.023), AUC difference test of 0.093 (p = 0.000023). The diagnostic accuracy of USGFNAB is higher than PGFNAB in diagnosing malignancy of thyroid nodules. If it is accessible, the author recommends using USGFNAB as a diagnostic tool for thyroid nodules.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Comparison of palpation-versus ultrasound-guided fine-needle aspiration biopsies in the evaluation of thyroid nodules
    Can A.S.
    Peker K.
    BMC Research Notes, 1 (1)
  • [22] Diagnostic accuracy of lower endoscopic ultrasound-guided fine-needle aspiration for pelvic lesions: a systematic review and meta-analysis
    Jiang, Fangyan
    Yu, Shuangcheng
    Su, Haiqing
    Zhang, Xia
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (03): : 5508 - 5516
  • [23] Diagnostic Value of Ultrasound-Guided Fine Needle Aspiration Biopsy in Malignant Thyroid Nodules: Utility for Micronodules
    Unal, Betul
    Sezer, Cem
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (20) : 8613 - 8616
  • [24] Diagnostic adequacy of surgeon-performed ultrasound-guided fine needle aspiration biopsy of thyroid nodules
    Cakmak, Guldeniz Karadeniz
    Emre, Ali U.
    Tascilar, Oge
    Gultekin, Fatma A.
    Ozdamar, Sukru O.
    Comert, Mustafa
    JOURNAL OF SURGICAL ONCOLOGY, 2013, 107 (02) : 206 - 210
  • [25] Diagnostic Accuracy of Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules
    Bohacek, Linda
    Milas, Mira
    Mitchell, Jamie
    Siperstein, Allan
    Berber, Eren
    ANNALS OF SURGICAL ONCOLOGY, 2012, 19 (01) : 45 - 51
  • [26] Diagnostic Accuracy of Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules
    Linda Bohacek
    Mira Milas
    Jamie Mitchell
    Allan Siperstein
    Eren Berber
    Annals of Surgical Oncology, 2012, 19 : 45 - 51
  • [27] Impact of ultrasound-guided fine needle aspiration cytology for diagnosis of thyroid nodules
    Wang, Jing
    Liu, Jing
    Liu, Zhe
    MEDICINE, 2019, 98 (38)
  • [28] Ultrasound-guided fine needle aspiration cytology in the diagnosis and management of thyroid nodules
    Cai, X. J.
    Valiyaparambath, N.
    Nixon, P.
    Waghorn, A.
    Giles, T.
    Helliwell, T.
    CYTOPATHOLOGY, 2006, 17 (05) : 251 - 256
  • [29] Ultrasound-guided fine needle aspiration biopsy of thyroid nodules ≤ 1.5 cm, is it useful?
    Shafi, N.
    Farghaly, H.
    MODERN PATHOLOGY, 2007, 20 : 82A - 82A
  • [30] The role of ultrasound-guided fine needle aspiration biopsy (USFNAB) in the management of thyroid nodules
    Kafaja, S
    Van Herle, A
    JOURNAL OF INVESTIGATIVE MEDICINE, 1999, 47 (02) : 22A - 22A