Screening for Nonclassic Congenital Adrenal Hyperplasia in the Era of Liquid Chromatography-Tandem Mass Spectrometry

被引:7
|
作者
Chesover, Alexander D. [1 ]
Millar, Heather [2 ]
Sepiashvili, Lusia [3 ]
Adeli, Khosrow [3 ]
Palmert, Mark R. [1 ,4 ]
Hamilton, Jill [1 ]
机构
[1] Univ Toronto, Hosp Sick Children, Dept Paediat, Div Endocrinol, Toronto, ON M5G 1H4, Canada
[2] Univ Toronto, Dept Obstet & Gynaecol, Div Endocrinol, Sect Gynaecol,Hosp Sick Children, Toronto, ON M5G 1H4, Canada
[3] Hosp Sick Children, Dept Paediat Lab Med, Toronto, ON M5G 1H4, Canada
[4] Univ Toronto, Dept Physiol, Toronto, ON M5S 1A8, Canada
关键词
congenital adrenal hyperplasia; 17-hydroxyprogesterone; mass spectrometry; 21-hydroxylase; cortisol; pediatrics; 21-HYDROXYLASE DEFICIENCY; WOMEN; 17-HYDROXYPROGESTERONE; DIAGNOSIS; GENOTYPE; CHILDREN; COHORT;
D O I
10.1210/jendso/bvz030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Context: Screening for and diagnosing non classic congenital adrenal hyperplasia (NCCAH) uses serum 17-hydroxyprogesterone (17OHP) thresholds established from immunoassay data; however, a new liquid-chromatography tandem mass spectrometry (LC-MS/MS) method results in lower l7OHP values. The evolution of immunoassays is also challenging our diagnostic cut-off for glucocorticoid insufficiency and few data re-evaluate the utility of testing for glucocorticoid insufficiency in NCCAH. Objective: (1) Evaluate the 17OHP threshold that predicts NCCAH in children using LC-MS/MS, and (2) determine the prevalence of glucocorticoid insufficiency in NCCAH. Methods: A retrospective chart review of pediatric patients who underwent ACTH stimulation tests with cortisol and 17OHP measurements from 2011 to 2018 for assessment of NCCAH. Other adrenal pathologies were excluded. A cortisol < 415 nmol/L defined glucocorticoid insufficiency. Published correlation data determined a 17OHP of 3.3 nmol/L by LC-MS/MS was equivalent to 6 nmol/L by immunoassay. Data analysis was by measures of diagnostic accuracy. Results: Of 188 patients included, 23 (12%) had NCCAH (21/23 had genetic confirmation); the remaining 2 had peak 17OHP > 30 nmol/L. Baseline 17OHP >= 6 nmol/L most accurately screened for NCCAH sensitivity and specificity 96%. Almost all genetically confirmed NCCAH (20/21) had peak 17OHP > 30 nmol/L; all subjects with other diagnoses peaked < 30 nmol/L. Glucocorticoid insufficiency was present in 55% with NCCAH. Conclusions: Despite the increased specificity of LC-MS/MS, a baseline 17OHP >= 6 nmol/L most accurately screened for NCCAH; this supports current practice guidelines. This threshold identified all with glucocorticoid insufficiency, notably prevalent in our cohort and for whom glucocorticoid stress dosing should be considered. (C) Endocrine Society 2019.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Improved screening capabilities in forensic toxicology by application of liquid chromatography-tandem mass spectrometry
    Thieme, D
    Sachs, H
    ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) : 171 - 186
  • [42] Screening of serum oxysterol biomarkers for colon cancer by liquid chromatography-tandem mass spectrometry
    Ma Zhanjun
    Li Zhenguo
    Wang Huan
    Wang Renjun
    Han Xiaofei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2022, 40 (06) : 541 - 546
  • [43] Comparison of supercritical fluid chromatography-tandem mass spectrometry and liquid chromatography-tandem mass spectrometry for the stereoselective analysis of chlorfenvinphos and dimethylvinphos in tobacco
    Yang, Fei
    Cui, Haozhe
    Wang, Chunqiong
    Wang, Ying
    Zhu, Wenjing
    Deng, Huimin
    Liu, Shanshan
    Bian, Zhaoyang
    Lu, Junli
    Tang, Gangling
    Ji, Yuan
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (19)
  • [44] Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry
    Lipicar, Eva
    Fras, Danijela
    Javernik, Nino
    Prosen, Helena
    TOXICS, 2023, 11 (01)
  • [45] A new era in protein quantification in clinical laboratories: Application of liquid chromatography-tandem mass spectrometry
    Hortin, Glen L.
    CLINICAL CHEMISTRY, 2007, 53 (04) : 543 - 544
  • [46] Calibrators for measuring aldosterone by liquid chromatography-tandem mass spectrometry
    Taylor, Paul J.
    Gordon, Richard D.
    Stowasser, Michael
    CLINICA CHIMICA ACTA, 2012, 413 (1-2) : 346 - 347
  • [47] The role of liquid chromatography-tandem mass spectrometry in the clinical laboratory
    van den Ouweland, Johannes M. W.
    Kema, Ido P.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 883 : 18 - 32
  • [49] Quantification of voriconazole in plasma by liquid chromatography-tandem mass spectrometry
    Vogeser, M
    Schiel, X
    Spöhrer, U
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (07) : 730 - 734
  • [50] Mucopolysaccharides quantitation in serum by liquid chromatography-tandem mass spectrometry
    Raymond, Kimiyo
    Lacey, Jean M.
    Dimitar, Gavrilov
    Matern, Dietrich
    Oglesbee, Devin
    Rinaldo, Piero
    Tortorelli, Silvia
    MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S123 - S123